Configuration Management (CM) Sample Clauses

Configuration Management (CM). 3.3.1.11.1 The Contractor shall assist with tracking and controlling changes in software and supporting data.‌
AutoNDA by SimpleDocs
Configuration Management (CM). The Contractor shall develop and deliver a Contractor’s Configuration Management (CM) Plan (CDRL A017). The Contractor shall utilize and implement the approved CM Plan policies and procedures to ensure traceability for each MK 48 MOD 7 APB6/TI-1 G&C Section, WES Kit, and Factory Test Equipment deliverable (including repair action), hardware, software and documentation management, change control, and status accounting during the contract period of performance. The Contractor’s CM Plan shall be developed using the Configuration Management Plan for Undersea Weapons Program (PMS404) PEO SUB S0199-133-A-O-C and National Consensus Standard for Configuration Management (ANSI/EIA-649_1) guidelines to establish and maintain a Product Baseline accordingly. The Contractor shall submit Engineering Change Proposals (ECP) (CDRL A019) with related Notice of Revisions (NORs) (CDRL A020) to document changes to the Contractor CM controlled MK 48 MOD 7 APB6/TI-1 items including G&C Section, WES Kit and Factory Test Equipment TDPs, Computer Software Products, Contractor developed, Government approved G&C Section FIR SSS-3, TRDs, SRSs, IRSs, IDDs, SDDs, ICSs and Critical Manufacturing Procedures (B001, B002, B003, B004, B005, B006, and B007, B008, B009, B010, B011, B019 and A016) after PRR. The Contractor shall submit Engineering Change Proposals (ECP) (CDRL A019) with related Notice of Revisions (NORs) (CDRL A020) detailing any proposed changes to Government CM controlled documents (Attachment 1 Contract Baseline). The Contractor shall submit any proposed Request for Variances (RFV) (CDRL A021). Request for Variance (RFV) (CDRL A021) shall be submitted by the Contractor when hardware to be delivered is not fully compliant with the Attachment 1 Contract Baseline requirements, Contractor Baseline requirements or TDP. All ECP, NOR, and RFV submissions shall provide rationale and justify that the affected items with the changes will be able to meet applicable contract baseline requirements; to provide sufficient details to convey the reasons of the technical changes or variations; to convey risks of the implementation; and to provide impacts if non-approval of the ECP or RFV occurs. The submissions shall also include a description of any testing performed and results as well as any analysis performed supporting the proposed change or variance. Final updated products including the proposed change(s) shall be submitted via CDRL concurrent with applicable ECPs, NORs, RFVs submission...
Configuration Management (CM). The Contractor shall conduct and maintain CM and change control processes IAW guidelines within EIA-649C and MIL-HDBK-61A for all DO configuration items, including software computer program configuration items (CPCI). The contractor shall maintain the system IAW the most current documented system configuration.

Related to Configuration Management (CM)

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Construction Management Plan Contractor shall prepare and furnish to the Owner a thorough and complete plan for the management of the Project from issuance of the Proceed Order through the issuance of the Design Professional's Certificate of Material Completion. Such plan shall include, without limitation, an estimate of the manpower requirements for each trade and the anticipated availability of such manpower, a schedule prepared using the critical path method that will amplify and support the schedule required in Article 2.1.5 below, and the Submittal Schedule as required in Article 2.2.3. The Contractor shall include in his plan the names and resumés of the Project Superintendent, Project Manager and the person in charge of Safety.

  • STATEWIDE CONTRACT MANAGEMENT SYSTEM If the maximum amount payable to Contractor under this Contract is $100,000 or greater, either on the Effective Date or at any time thereafter, this section shall apply. Contractor agrees to be governed by and comply with the provisions of §§00-000-000, 00-000-000, 00-000-000, and 00- 000-000, C.R.S. regarding the monitoring of vendor performance and the reporting of contract information in the State’s contract management system (“Contract Management System” or “CMS”). Contractor’s performance shall be subject to evaluation and review in accordance with the terms and conditions of this Contract, Colorado statutes governing CMS, and State Fiscal Rules and State Controller policies.

  • Project Management Plan 1 3.4.1 Developer is responsible for all quality assurance and quality control 2 activities necessary to manage the Work, including the Utility Adjustment Work.

  • Program Management 1.1.01 Implement and operate an Immunization Program as a Responsible Entity

  • Quality Management System Supplier hereby undertakes, warrants and confirms, and will ensue same for its subcontractors, to remain certified in accordance with ISO 9001 standard or equivalent. At any time during the term of this Agreement, the Supplier shall, if so instructed by ISR, provide evidence of such certifications. In any event, Supplier must notify ISR, in writing, in the event said certification is suspended and/or canceled and/or not continued.

  • Contract Management To ensure full performance of the Contract and compliance with applicable law, the System Agency may take actions including:

  • Enterprise Information Management Standards Grantee shall conform to HHS standards for data management as described by the policies of the HHS Office of Data, Analytics, and Performance. These include, but are not limited to, standards for documentation and communication of data models, metadata, and other data definition methods that are required by HHS for ongoing data governance, strategic portfolio analysis, interoperability planning, and valuation of HHS System data assets.

  • PERFORMANCE MANAGEMENT SYSTEM 5.1 The Employee agrees to participate in the performance management system that the Employer adopts or introduces for the Employer, management and municipal staff of the Employer.

Time is Money Join Law Insider Premium to draft better contracts faster.