Common use of Connecting Transmission Owner’s Attachment Facilities Clause in Contracts

Connecting Transmission Owner’s Attachment Facilities. The PCO and the Point of Interconnection (“POI”) are designated on Figure A-1 to this Appendix A. The Connecting Transmission Owner’s Attachment Facilities (“CTOAFs”) include the facilities between the PCO and the POI. As depicted in Figure A-1, the CTOAFs include the following major electrical and physical equipment: (1) line disconnect switch, motor operated, three-phase vertical break, 230 kV nominal, 900 kV basic insulation level (“BIL”), 2000 A continuous;

Appears in 7 contracts

Samples: Interconnection Agreement, Interconnection Agreement, Interconnection Agreement

AutoNDA by SimpleDocs

Connecting Transmission Owner’s Attachment Facilities. The PCO and the Point of Interconnection (“POI”) are designated on Figure A-1 to this Appendix A. The Connecting Transmission Owner’s Attachment Facilities (“CTOAFs”) include the facilities between from the PCO and to the POI. As depicted in Figure A-1, the CTOAFs include the following major electrical and physical equipment: : • One (1) line 123 kV, 2000 Amps continuous, 100 kA momentary capability, 550 kV BIL gang operated disconnect switch, motor operated, three-phase vertical break, 230 kV nominal, 900 kV basic insulation level (“BIL”), 2000 A continuous;

Appears in 3 contracts

Samples: Lgia, Interconnection Agreement, Interconnection Agreement

Connecting Transmission Owner’s Attachment Facilities. The PCO and the Point of Interconnection (“POI”) are designated on in Figure A-1 to this Appendix A. The Connecting Transmission Owner’s Attachment Facilities (“CTOAFs”) include the facilities between from the PCO and to the POI. As depicted in Figure A-1, the CTOAFs include the following major electrical and physical equipment: (1) line disconnect switchLine Disconnect Switch, motor operated, three3-phase phase, vertical break, 230 115 kV nominal, 900 121 kV basic insulation level (“maximum system voltage, 550 kV BIL”), 2000 A continuousContinuous with 3- phase manual group operated ground switch;

Appears in 2 contracts

Samples: Interconnection Agreement, Interconnection Agreement

Connecting Transmission Owner’s Attachment Facilities. The PCO and the Point of Interconnection (“POI”) are designated on Figure A-1 to this Appendix A. The Connecting Transmission Owner’s Attachment Facilities (“CTOAFs”) include the facilities between the PCO and the POI. As depicted in Figure A-1, the CTOAFs include the following major electrical and physical equipment: : • One (1) 115 kV, 2000 A, group-operated line disconnect switch, motor operated, three-phase vertical break, 230 kV nominal, 900 kV basic insulation level switch for connection to the Generator Lead Line (“BIL”Line 3), 2000 A continuous;

Appears in 1 contract

Samples: Interconnection Agreement

AutoNDA by SimpleDocs

Connecting Transmission Owner’s Attachment Facilities. The PCO and the Point of Interconnection (“POI”) are designated on Figure A-1 to this Appendix A. The Connecting Transmission Owner’s Attachment Facilities (“CTOAFs”) include the facilities between the PCO and the POI. As depicted in Figure A-1, the CTOAFs include the following major electrical and physical equipment: : • One (1) line disconnect switch230 kV, motor operated3000 Amps continuous, three-phase vertical break, 230 kV nominal100 kA momentary capability, 900 kV basic insulation level (“BIL”), 2000 A continuousBIL gang operated disconnect switch with motor operator;

Appears in 1 contract

Samples: Interconnection Agreement