Determination of the particulates Sample Clauses

Determination of the particulates. Paragraphs 1.2.1. and 1.2.2. and figures 4 to 15 contain detailed descriptions of the recommended dilution and sampling systems. Since various configurations can produce equivalent results, exact conformance with these figures is not required. Additional components such as instruments, valve, solenoids, pumps and switches may be used to provide additional information and co-ordinate the functions of the component systems. Other components which are not needed to maintain the accuracy on some systems, may be excluded if their exclusion is based upon good engineering judgement.
AutoNDA by SimpleDocs
Determination of the particulates. The determination of the particulates requires a dilution system. Dilution may be accomplished by a partial flow dilution system or a full flow dilution system. The flow capacity of the dilution system shall be large enough to completely eliminate water condensation in the dilution and sampling systems, and maintain the temperature of the diluted exhaust gas between 315 K (42 °C) and 325 K (52 °C) immediately upstream of the filter holders. De-humidifying the dilution air before entering the dilution system is permitted, if the air humidity is high. Dilution air pre-heating above the temperature limit of 303 K (30 °C) is recommended, if the ambient temperature is below 293 K (20 °C). However, the diluted air temperature shall not exceed 325 K (52 °C) prior to the introduction of the exhaust in the dilution tunnel.
Determination of the particulates. The determination of the particulates requires a dilution system. Dilution may be accomplished by a partial flow dilution system or a full flow dilution system. The flow capacity of the dilution system shall be large enough to completely eliminate water condensation in the dilution and sampling systems, and maintain the temperature of the diluted exhaust gas at or below 325K (52 °C) immediately upstream of the filter holders. De-humidifying the dilution air before entering the dilution system is permitted, if the air humidity is high. Dilution air pre-heating above the temperature limit of 303K (30 °C) is recommended, if the ambient temperature is below 293K (20 °C). However, the diluted air temperature must not exceed 325K (52 °C) prior to the introduction of the exhaust in the dilution tunnel. For a partial flow dilution system, the particulate sampling probe must be fitted close to and upstream of the gaseous probe as defined in paragraph 4.4. and in accordance with Annex 4, Appendix 4, paragraph 1.2.1.1., figures 4-12, EP and SP.
Determination of the particulates. Determination of the particulates requires a dilution system. Dilution may be accomplished by a partial flow dilution system or a full flow dilution system. The flow capacity of the dilution system shall be large enough to completely eliminate water condensation in the dilution and sampling systems, and maintain the temperature of the diluted exhaust gas between 315 K (42 °C) and 325 K (52 °C) immediately upstream of the filter holders. De-humidifying the dilution air before entering the dilution system is permitted, if the air humidity is high. Dilution air pre-heating above the temperature limit of 303 K (30 °C) is recommended if the ambient temperature is below 293 K (20 °C). However, the diluted air temperature shall not exceed 325 K (52 °C) prior to the introduction of the exhaust in the dilution tunnel. The particulate sampling probe shall be installed in close proximity to the gaseous emissions sampling probe, and the installation shall comply with the provisions of paragraph 2.3.5. above. 90 To determine the mass of the particulates, a particulate sampling system, particulate sampling filters, microgram balance, and a temperature and humidity controlled weighing chamber, are required. Partial flow dilution system specifications
Determination of the particulates. The determination of the particulates requires a dilution system capable of maintaining the temperature of the diluted exhaust gas at or below 325 K (52 °C) and preventing water condensation, a particulate sampling system, specified particulate sampling filters and a microgram balance which shall be placed in an air-conditioned weighing chamber. Dilution may be accomplished by a full-flow dilution or a partial-flow dilution system. Annex 4, appendix 4 describes the analytical systems in current use. Other systems which have proved to give equivalent results may be used. E/ECE/324 Rev.1/Add.48/Rev.3 Regulation No. 49 page 39 Annex 4 - Appendix 2

Related to Determination of the particulates

  • Determination of Responsiveness 28.1 The Procuring Entity's determination of a Tender's responsiveness is to be based on the contents of the Tender itself, as defined in ITT28.2.

  • Determination of Position(s) The Appointing Authority shall determine the position(s) in the class or class option, if one exists, and employment condition and work location which is to be eliminated.

  • Determination of Seniority Seniority records shall be maintained by the University and shall be based on the employee's seniority date. The University shall maintain current records on seniority for use in the application of these provisions and they shall be available whenever a Union representative shall raise a question of seniority. Such lists and records shall also show the job title and latest employment date with the University for each person, and a copy of the list shall be furnished to the Union every six (6) months, upon request.

  • Determination of Clearing Price The Selling Shareholder and the Placement Agents shall have determined, in writing, the clearing price for the Securities in the Auction.

  • Determination of Agreement 29. (1) In any of the following events namely if —

  • Independence from Material Breach Determination Except as set forth in Section X.D.1.c, these provisions for payment of Stipulated Penalties shall not affect or otherwise set a standard for OIG’s decision that CHSI has materially breached this CIA, which decision shall be made at OIG’s discretion and shall be governed by the provisions in Section X.D, below.

  • Determination of Eligibility The Plan Administrator shall determine the eligibility of each Employee for participation in the Plan based upon information provided by the Employer. Such determination shall be conclusive and binding on all individuals except as otherwise provided herein or by operation of law.

  • Non-Grievability No dispute over a claim for any benefits extended by this Health and Welfare Fund shall be subject to the grievance procedure.

  • Determination of Cost The Design Professional shall review the Contractor’s proposed cost of the work, time to complete, effect upon the Overall Progress Schedule, and effect upon time dependent costs, and provide appropriate comments within fourteen calendar days concerning such proposed costs and expenses.

  • DETERMINATION OF HUB PARTICIPATION A firm must be an eligible HUB and perform a professional or technical function relating to the project. Proof of payment, such as copies of canceled checks, properly identifying the Department’s contract number or project number may be required to substantiate the payment, as deemed necessary by the Department. A HUB subprovider, with prior written approval from the Department, may subcontract 70% of a contract as long as the DocuSign Envelope ID: 1FDB1C48-24B1-4C40-8A33-17263E465FE2 HUB subprovider performs a commercially useful function. All subcontracts shall include the provisions required in the subcontract and shall be approved as to form, in writing, by the Department prior to work being performed under the subcontract. A HUB performs a commercially useful function when it is responsible for a distinct element of the work of a contract; and actually manages, supervises, and controls the materials, equipment, employees, and all other business obligations attendant to the satisfactory completion of contracted work. If the subcontractor uses an employee leasing firm for the purpose of providing salary and benefit administration, the employees must in all other respects be supervised and perform on the job as if they were employees of the subcontractor.

Time is Money Join Law Insider Premium to draft better contracts faster.