Service Charges No service charge shall be made for any exchange or registration of transfer of Warrants.
Service Charge The Tenant must pay the Service Charge in accordance with Part 1 of Schedule 3. VAT The Tenant must pay: VAT on any consideration in respect of a VAT Supply to the Tenant by the Landlord at the same time as the consideration is paid; and on demand VAT (and interest, penalties and costs where these are incurred because of anything the Tenant does or fails to do) charged in respect of any VAT Supply to the Landlord in respect of the Premises where that VAT is not recoverable by the Landlord from HM Revenue & Customs. The Tenant must not do anything that would result in the disapplication of the option to tax in respect of the Landlord’s interest in the Estate. Interest on overdue payments The Tenant must pay interest on the Rents and on all other sums not paid on or by the due date (or, if no date is specified, not paid within 10 Business Days after the date of demand). Interest will be payable at the Interest Rate for the period starting on the due date (or date of demand) and ending on the date of payment. Reimburse costs incurred by the Landlord The Tenant must pay on demand the Landlord’s costs (including legal and surveyor’s charges and bailiff’s and enforcement agent’s fees) and disbursements in connection with: any breach of the Tenant’s obligations in this Lease, including the preparation and service of a notice under section 146 of the 1925 Act; any application by the Tenant for consent under this Lease, whether that application is withdrawn or consent is granted or lawfully refused, except in cases where the Landlord is required to act reasonably and the Landlord unreasonably refuses to give consent; [and] [carrying out works to the Premises to improve their Environmental Performance where the Tenant, in its absolute discretion, has consented to the Landlord doing so; and]44 the preparation and service of a schedule of dilapidations served no later than six months after the End Date. Third party indemnity45 The Tenant must indemnify the Landlord against all actions, claims, demands made by a third party, all costs, damages, expenses, charges and taxes payable to a third party and the Landlord’s own liabilities, costs and expenses incurred in defending or settling any action, claim or demand in respect of any personal injury or death, damage to any property and any infringement of any right, in each case arising from: the state and condition of the Premises or the Tenant’s use of them; the exercise of the Tenant’s rights; or the carrying out of any Permitted Works. In respect of any claim covered by the indemnity in clause 4.7.1, the Landlord must: give formal notice to the Tenant of the claim as soon as reasonably practicable after receiving notice of it; provide the Tenant with any information and assistance in relation to the claim that the Tenant may reasonably require and the Landlord is lawfully able to provide, subject to the Tenant paying to the Landlord all costs incurred by the Landlord in providing that information and assistance; and mitigate its loss (at the Tenant’s cost) where it is reasonable for the Landlord to do so.
Monthly Billing The electric service charge shall be computed in accordance with the monthly billing in the applicable standard service tariff. Customers receiving electric service under residential and small nonresidential schedules 1, 2, 3, 15, 23 or 23B shall be financially credited for such net energy with a cumulative kilowatt-hour credit. The credit will be deducted from the customer’s kilowatt-hour usage on the customer’s next monthly xxxx thus offsetting the customer’s next monthly xxxx at the full retail rate of the customer’s rate schedule. Customers receiving electric service under large nonresidential schedules 6, 6A, 6B, 8 or 10 must elect a compensation method to receive cumulative credits for the upcoming annualized billing period from one of the following options (large nonresidential customers must initial desired credit election): an average energy price, a seasonally differentiated energy price, or an average retail rate.
Monthly Fee 2.1 The monthly fee is € . The monthly fee includes value-added tax at the statutory rate, which is currently 19%. In the event of changes to the statutory value-added tax payable and/or if any additional taxes/levies have to be paid, the fee specified above may be recalculated accordingly. A onetime service fee of €19.90 incl. VAT is charged when taking out a membership and is collected with the first direct debit.
CAISO Monthly Billed Fuel Cost [for Geysers Main only] The CAISO Monthly Billed Fuel Cost is given by Equation C2-1. CAISO Monthly Billed Fuel Cost Equation C2-1 = Billable MWh 🟏 Steam Price ($/MWh) Where: • Steam Price is $16.34/MWh. • For purposes of Equation C2-1, Billable MWh is all Billable MWh Delivered after cumulative Hourly Metered Total Net Generation during the Contract Year from all Units exceeds the Minimum Annual Generation given by Equation C2-2. Equation C2-2 Minimum Annual Generation = (Annual Average Field Capacity 🟏 8760 hours 🟏 0.4) - (A+B+C) Where: • Annual Average Field Capacity is the arithmetic average of the two Field Capacities in MW for each Contract Year, determined as described below. Field Capacity shall be determined for each six-month period from July 1 through December 31 of the preceding calendar year and January 1 through June 30 of the Contract Year. Field Capacity shall be the average of the five highest amounts of net generation (in MWh) simultaneously achieved by all Units during eight-hour periods within the six-month period. The capacity simultaneously achieved by all Units during each eight-hour period shall be the sum of Hourly Metered Total Net Generation for all Units during such eight-hour period, divided by eight hours. Such eight-hour periods shall not overlap or be counted more than once but may be consecutive. Within 30 days after the end of each six-month period, Owner shall provide CAISO and the Responsible Utility with its determination of Field Capacity, including all information necessary to validate that determination. • A is the amount of Energy that cannot be produced (as defined below) due to the curtailment of a Unit during a test of the Facility, a Unit or the steam field agreed to by CAISO and Owner. • B is the amount of Energy that cannot be produced (as defined below) due to the retirement of a Unit or due to a Unit’s Availability remaining at zero after a period of ten Months during which the Unit’s Availability has been zero. • C is the amount of Energy that cannot be produced (as defined below) because a Force Majeure Event reduces a Unit’s Availability to zero for at least thirty (30) days or because a Force Majeure Event reduces a Unit’s Availability for at least one hundred eighty (180) days to a level below the Unit Availability Limit immediately prior to the Force Majeure Event. • The amount of Energy that cannot be produced is the sum, for each Settlement Period during which the condition applicable to A, B or C above exists, of the difference between the Unit Availability Limit immediately prior to the condition and the Unit Availability Limit during the condition.