Master Meters Sample Clauses

Master Meters. Toledo agrees to use Master Meters for the purpose of measuring the volumes of water supplied by Toledo and purchased by the Contracting Jurisdiction for the its Service Area (excepting Xxxxx County). Toledo shall own the Master Meters. The Contracting Jurisdiction shall convey to Toledo at no cost within sixty (60) days of the Effective Date of this Uniform Water Agreement both (i) the Master Meters it owns on the Effective Date of this Agreement, and (ii) any necessary easements required to replace, maintain or otherwise access the Master Meters. Toledo may, at Toledo’s expense, supply, test, maintain, replace and calibrate all Master Meters, radio transmitters and related appurtenances thereto. The Master Meters shall be installed and maintained at Connection Point locations off of Toledo water mains or off of water mains of other Contracting Jurisdictions to be agreed upon between the parties (collectively, “Connection Points”), or as exist on the Effective Date of this Uniform Water Agreement; and each party shall have unrestricted access at all times to such Master Meters and appurtenances, and Master Meter reports for inspection, reading, and proper billing by authorized officers and employees of the parties.
AutoNDA by SimpleDocs
Master Meters. The City shall be responsible for ownership, operation, maintenance and repair of the Master Meters.

Related to Master Meters

  • Meters 7.1.1 For installation of Meters, Meter testing, Meter calibration and Meter reading and all matters incidental thereto, the SPD and SECI shall follow and be bound by the Central Electricity Authority (Installation and Operation of Meters) Regulations, 2006, the Grid Code, as amended and revised from time to time.

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

  • Check Meters Developer, at its option and expense, may install and operate, on its premises and on its side of the Point of Interconnection, one or more check meters to check Connecting Transmission Owner’s meters. Such check meters shall be for check purposes only and shall not be used for the measurement of power flows for purposes of this Agreement, except as provided in Article 7.4 below. The check meters shall be subject at all reasonable times to inspection and examination by Connecting Transmission Owner or its designee. The installation, operation and maintenance thereof shall be performed entirely by Developer in accordance with Good Utility Practice.

  • Local Control Center, Metering and Telemetry The NTO shall operate, pursuant to ISO Tariffs, ISO Procedures, Reliability Rules and all other applicable reliability rules, standards and criteria on a twenty-four (24) hour basis, a suitable local control center(s) with all equipment and facilities reasonably required for the ISO to exercise ISO Operational Control over NTO Transmission Facilities Under ISO Operational Control, and for the NTO to fulfill its responsibilities under this Agreement. Operation of the NYS Power System is a cooperative effort coordinated by the ISO control center in conjunction with local control centers and will require the exchange of all reasonably necessary information. The NTO shall provide the ISO with Supervisory Control and Data Acquisition (“SCADA”) information on facilities listed in Appendices A-1 and A-2 herein as well as on generation and merchant transmission resources interconnected to the NTO’s transmission facilities pursuant to the ISO OATT. The NTO shall provide metering data for its transmission facilities to the ISO, unless other parties are authorized by the appropriate regulatory authority to provide metering data. The NTO shall collect and submit to the ISO billing quality metering data and any other information for its transmission facilities required by the ISO for billing purposes. The NTO shall provide to the ISO the telemetry and other operating data from generation and merchant transmission resources interconnected to its transmission facilities that the ISO requires for the operation of the NYS Power System. The NTO will establish and maintain a strict code of conduct to prevent such information from reaching any unauthorized person or entity.