MEN’S TOILET ROOM Sample Clauses

MEN’S TOILET ROOM. (Lower East Concourse)
AutoNDA by SimpleDocs
MEN’S TOILET ROOM a. The toilet room sign is inaccessible. Provide a toilet room sign with raised and Braille characters. The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing. Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.
MEN’S TOILET ROOM i. The room signage is mounted on the wall to the hinge side of the door. Provide a toilet room sign with the International Symbol of Accessibility and raised and Braille characters. The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing. Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6, 4.30.7. ii. The door to the toilet room, which is accessed through a front approach, is inaccessible because it has insufficient maneuvering space on the pull/latch side. On the pull side of the door, provide maneuvering clearance at least 60 inches deep and provide a minimum of 18 inches (24 inches is preferred) of maneuvering clearance on the latch side of the door. Standards § 4.13.6, Fig. 25(a). Alternatively, provide an automatic door opener inside the room. iii. The toilet seat cover dispenser is mounted too high and is above the toilet. Provide a toilet seat cover dispenser such that the controls comply with Fig. 5 for a forward reach or with Fig. 6 for a side reach and such that it is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair. Standards §§ 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6.
MEN’S TOILET ROOM a. The pressure required to open the door to the men’s toilet room is 18 pounds. Provide a door closer so that the force required to open the door is no more than 5 pounds. §§ 4.1.3(7)(b), 4.13.11(2)(b). b. The paper towel dispenser in the toilet room is located 64 inches above the finished floor. Provide a paper towel dispenser so that it is not in the circulation path to the lavatory, has its highest operable part within the reach ranges of a person who uses a wheelchair, and has a clear floor space of 30 inches by 48 inches. §§ 4.1.3(2), 4.4.1, 4.4.2, 4.1.3(11), 4.22.7, 4.27.2, 4.27.3, 4.2.5, 4.2.6. c. The toilet paper dispenser in the designated accessible stall is located above the side grab bar and 42 inches above the finished floor. Provide a toilet paper dispenser so that there is a minimum of 1 1/2 inches between the bottom of the grab bar and the top of the toilet paper dispenser, and the centerline of the toilet paper dispenser is a minimum of 19 inches above the finished floor with the paper outlet at least 9 inches above the floor. §§ 4.1.3(11), 4.22.4, 4.17.3 and Fig. 30(d), 4.2.6. d. The toilet seat cover dispenser in the designated accessible stall is 52 inches above the finished floor. Provide a toilet seat cover dispenser that is within the reach ranges of a person using a wheelchair in an area where there is a 30 inch by 48 inch clear floor space adjacent to the dispenser. §§ 4.1.3(11), 4.22.7, 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6. The County shall complete the following alterations to the WORCESTER COUNTY HEALTH CENTER located at 0000 Xxxxxx Xxxxxxx Xxxx, within one year of the effective date of this Agreement: 63. MEN’S AND WOMEN’S TOILET ROOMS
MEN’S TOILET ROOM a. The toilet room sign is inaccessible. Provide a toilet room sign with raised and Braille characters. The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing. Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6. b. The door to the toilet room stall is inaccessible because the door has a twist lock device. Provide a door with hardware usable with one hand and without tight grasping, pinching, or twisting of the wrist. Lever-operated, push-type, and U-shaped handles are acceptable designs. Standards §§ 4.1.3(11), 4.22.2, 4.13.9. c. There is no rear grab bar. Provide a rear grab bar that is at least 36 inches in overall length, with the closer end no more than 6 inches from the side wall; mounted 33 to 36 inches above the finished floor; with a diameter between 1 1/4 and 1 1/2 inches; with 1 1/2 inches between the grab bar and the wall; and at least 1 1/2 inches between the grab bar and any other object, such as a toilet seat cover dispenser. Standards §§ 4.1.3(11), 4.22.4, 4.17.6, 4.26.2, Fig. 30. d. There is no side grab bar. Provide a side grab bar that is at least 40 inches in overall length, with the far end mounted at least 54 inches from the rear wall and the closer end 12 inches or less from the rear wall; mounted 33 to 36 inches above the finished floor; with a diameter between 1 1/4 and 1 1/2 inches; with 1 1/2 inches between the grab bar and the wall; and at least 1 1/2 inches between the grab bar and any other object, such as the toilet paper dispenser. Standards §§ 4.1.3(11), 4.22.4, 4.17.6, 4.26.2, Fig. 30. e. The toilet paper dispenser is inaccessible because it is located 42 inches from the back wall and 22 to 30 inches above the finished floor. Provide a toilet paper dispenser that is mounted with its top at least 1 1/2 inches under the side grab bar and 36 inches or less from the rear wall and is centered at least 19 inches above the finished floor. Standards §§ 4.1.3(11), 4.22.4, 4.17.3, Fig. 30(d). f. The urinal is inaccessible because the rim is 22 1/4 inches above the finished floor and the flush control is mounted 49 inches above the finished floor. Provide a urinal with an elongated rim mounted 17 inches or less above the finished floor, a clear floor space of at least 30 inches wide and 48 inches dee...
MEN’S TOILET ROOM a. The toilet room sign is inaccessible. Provide a toilet room sign with raised and Braille characters. The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing. Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6. b. The toilet is inaccessible because the designated accessible stall measures 60 inches by 28 inches so there is insufficient clear floor space. Provide clear floor space that complies with Fig. 30 at the toilet. Standards § 4.17.3, Fig. 30. c. The side grab bar at the toilet is inaccessible because it is 1 inch in diameter and has a 4 1/2 inch space between it and the wall on which it is mounted. Provide a side grab bar that is at least 40 inches in overall length, with the far end mounted at least 52 inches from the rear wall and the closer end 12 inches or less from the rear wall; mounted 33 to 36 inches above the finished floor; with a diameter between 1 1/4 and 1 1/2 inches; with 1 1/2 inches between the grab bar and the wall; and at least 1 1/2 inches between the grab bar and any other object, such as the toilet paper dispenser. Standards §§ 4.17.6, 4.26.2, Figs. 30(a), (d). d. The paper towel dispenser is inaccessible because the controls are mounted 61 inches above the finished floor. Provide a paper towel dispenser with the controls a maximum height above the finished floor of 48 inches for a forward approach or 54 inches for a side approach and that is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach by a person using a wheelchair. Standards §§ 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6. LAFAYETTE COUNTY LIBRARY

Related to MEN’S TOILET ROOM

  • Toilet Tiles for floor or any other similar. • Walls –Tiles on the walls upto door height. • Sanitary ware of good quality. • Chrome plated fittings of good quality • Electrical point for geyser and exhaust fan. • Plumbing provision for Hot/Cold water line in shower.

  • Toilets Papers, dust, cobwebs, peels, cans/bottles, cigarette butts, excrement on floor, bad smells, water pools, leaking sewage, rodents, animals (dead or alive), overflowing sanitary bins. 0 = NOT APPLICABLE 1 = UNACCEPTABLE (Toilets out of order. Toilets not cleaned on daily basis.) 2 = POOR (Toilets cleaned, but still visible signs of dirt, e.g. dust, cobwebs.) 3 = GOOD (Obvious sign that toilets are cleaned daily.) 4 = EXCELLENT (Extra effort is put in to ensure cleanliness, e.g. using detergents.)

  • Toileting the ability to use the lavatory or otherwise manage bowel and bladder functions so as to maintain a satisfactory level of personal hygiene;

  • Carpet Cleaning Shampooing carpets with the deep dirt extraction (steam cleaning) method per manufactures recommendations.

  • Restrooms The restrooms, toilets, urinals, vanities and the other apparatus shall not be used for any purpose other than that for which they were constructed, and no foreign substance of any kind whatsoever shall be thrown therein. The expense of any breakage, stoppage or damage resulting from the violation of this rule shall be borne by the Tenant whom, or whose employees or invitees, shall have caused it.

  • Bathrooms Record the number of bathrooms found on the concerned premises. (7) Common Areas. Furnish the number of common or communal areas available to the Roommates on the premises. (8) Private Areas. Report the number of private rooms or areas found on the premises that the Roommates can access and utilize (alone). III. Term (9)

  • Dressing Rooms 42.1 Adequate dressing rooms with standard size lockers and sitting areas shall be provided if the physical facilities permit.

  • Lockers Where working conditions or weather requires regular employees to have additional clothing available at their regular point of assembly, the Employer shall provide appropriate secure individual lockers within the assembly room building.

  • Toilet Facilities The Employer provides the Contractor access to toilet facilities. Temporary chemical toilets are provided by the Contractor where deemed necessary.

  • KITCHEN  Discard all leftover food in large trash receptacle in kitchen and empty any smaller trash receptacles if used into large trash can in kitchen.  Empty large trash bin into the dumpster, (if feasible). If not, please notify front desk.  Flatware is to be pre-soaked, washed in dishwasher, dried, returned to drawers and placed facing in the same direction.  Dishes, glassware, chopping boards, cooking utensils, pots/pans, baking sheets etc. should be washed in accordance with the instructions on the dish washing machine and returned DRY to dish carts and cupboards. Please check for lipstick/chap stick marks and clean those off accordingly before putting glasses/cups away.  Wipe down outside of dishwasher, empty dishwasher food trap into trash and wash out.  Counters and sinks wiped down with the water and bleach solution.  If used, please wipe inside and out microwave oven; wall/warming ovens, inside the refrigerator and refrigerator door.  Run garbage disposal in large double sink by dishwashing machine to clear food waste (Please do not put any food waste in small sinks).  Wipe out Alto-Shaam (Warming Ovens) and clean food trays if used.  Rinse out any Dish Tubs.  Empty any tubs of excess ice outside, if used.  Sweep floor of food debris.  Empty large trash bin into the dumpster (if feasible). If not please notify front desk. B BQ’s:  Make sure propane is turned off after use  Clean grill racks with wire brush and wipe up any spills /food debris from the BBQ  Leave outside to cool.  Please check with Front Desk regarding storage of cold and cleaned BBQ’s PATIO:  Return outdoor umbrellas and furniture to original positions.  Wipe down outdoor furniture if spills have occurred.  Dispose of trash/food waste and cigarette butts in trash receptacles. The following applies if any food and/or beverages have been served in these rooms: GREAT ROOM:  Wipe down tables with bleach /water solution. (Located under the sink in the kitchen next to the coffee maker).  If linens have been used or rented, please shake off any food debris in trash receptacles and place linens in mesh bags provided. Sorting by color or type is not necessary.  Notify front desk of any beverage spills as soon as they occur.  Empty any trash receptacles into large trash can in kitchen and then empty that into the dumpster (if feasible). If not please notify front desk.  Sweep/Vacuum carpet of any food debris. (These items are located in the cupboard next to Men’s restroom.