Obligation of the Parties to supply devices Sample Clauses

Obligation of the Parties to supply devices. Shipper shall supply, operate and maintain, or cause to be supplied, operated and maintained, suitable gauging devices for the LNG tanks of the LNG Ships, as well as pressure and temperature measuring devices and all other measurement or testing devices that are incorporated in the structure of such LNG Ships or customarily maintained on board of the LNG Ships for accurate LNG cargo custody transfer. Terminal Operator shall supply, operate and maintain, or cause to be supplied, operated and maintained, devices required for collecting continuous and discontinuous (for monitoring and as a back-up) samples and for determining quality and composition of the delivered LNG and all other measurement or testing devices that are necessary to perform the measurement and testing required hereunder at the LNG Terminal. Tank gauge tables of LNG Ships Shipper shall furnish Terminal Operator or cause Terminal Operator to be furnished, a certified copy of tank gauge tables as described in section 3.4 of the LNG Access Code for each tank of each LNG Ship. Gauging and measuring LNG volumes unloaded or loaded Volumes of LNG delivered under this LTA shall be determined by gauging the LNG in the tanks of the LNG Ship(s) immediately before and after unloading or loading. Gauging the liquid in the tanks of the LNG Ship(s) and the measuring of liquid temperature, vapour temperature and vapour pressure in each LNG tank and the trim and list of the LNG Ship(s) shall be performed, or caused to be performed, by Shipper and may be witnessed by both Parties before and after unloading or loading. Copies of gauging and measurement records shall be furnished to Terminal Operator, and in the absence of manifest error, shall be conclusive. Gauging devices shall be selected, and measurements shall be effected, in accordance with the terms of section 3.4 of the LNG Access Code. Samples for quality analysis Representative samples of the unloaded or loaded LNG shall be obtained or caused to be obtained by Terminal Operator during the time of unloading or loading as provided in section 3.4 the LNG Access Code. Quality analysis Unless otherwise agreed, the samples referred to in GC 5.1.5 shall be analysed, or caused to be analysed by Terminal Operator in accordance with the terms of section 3.4 of the LNG Access Code to determine the molar fraction of the hydrocarbons and other components in the sample. Operating procedures Shipper, at no cost to Terminal Operator, shall procure that all measurem...
AutoNDA by SimpleDocs
Obligation of the Parties to supply devices. Shipper shall supply, operate and maintain, or cause to be supplied, operated and maintained, suitable gauging devices for the LNG tanks of the LNG Ships, as well as pressure and temperature measuring devices and all other measurement or testing devices that are incorporated in the structure of such LNG Ships or customarily maintained on board of the LNG Ships for accurate LNG cargo custody transfer. Terminal Operator shall supply, operate and maintain, or cause to be supplied, operated and maintained, devices required for collecting continuous and discontinuous (for monitoring and as a back-up) samples and for determining quality and composition of the delivered LNG and all other measurement or testing devices that are necessary to perform the measurement and testing required hereunder at the LNG Terminal.

Related to Obligation of the Parties to supply devices

  • OBLIGATION TO SUPPORT ‌ The parties agree that subsequent to the execution of this Memorandum of Understanding and during the period of time said Memorandum is pending before the Board of Supervisors for action, neither SEIU Local 721, nor Management, nor their authorized representatives, will appear before the Board of Supervisors or meet with members of the Board of Supervisors individually to advocate any amendment, addition or deletion to the terms and conditions of this Memorandum of Understanding. It is further understood that this Article shall not preclude the parties from appearing before the Board of Supervisors nor meeting with individual members of the Board of Supervisors to advocate or urge the adoption and approval of this Memorandum of Understanding in its entirety.

  • Obligation of the Parties The parties agree to the following obligations under this MOU:

  • Obligations of the Licensee 5.1.1. The Licensee’s Responsibilities and Duties shall include the following, in addition to and without prejudice to other obligations under this Agreement:

  • Parties Obligations The Parties’ obligations under this Agreement will continue notwithstanding the existence of a Material Change.

  • Obligations of the Concessionaire 5.1.1 Subject to and on the terms and conditions of this Agreement, the Concessionaire shall, at its own cost and expense, procure finance for and undertake the design, engineering, procurement, construction, operation and maintenance of the Project and observe, fulfil, comply with and perform all its obligations set out in this Agreement or arising hereunder.

  • OBLIGATIONS OF THE SUPPLIER In addition to the Article 4.2 of the GPC, it is specified that:

  • Licensee’s Obligations The Licensee agrees and undertakes:

  • Obligations of the Processor 6.1 The Processor shall:

  • Modification of the Small Generating Facility The Interconnection Customer must receive written authorization from the NYISO and Connecting Transmission Owner before making any change to the Small Generating Facility that may have a material impact on the safety or reliability of the New York State Transmission System or the Distribution System. Such authorization shall not be unreasonably withheld. Modifications shall be done in accordance with Good Utility Practice. If the Interconnection Customer makes such modification without the prior written authorization of the NYISO and Connecting Transmission Owner, the Connecting Transmission Owner shall have the right to temporarily disconnect the Small Generating Facility. If disconnected, the Small Generating Facility will not be reconnected until the unauthorized modifications are authorized or removed.

  • Obligations of the University (a) organizes the doctoral studies;

Time is Money Join Law Insider Premium to draft better contracts faster.