PLUMBING, SANITARY EQUIPMENT AND SEWER BLOCKAGES Sample Clauses

PLUMBING, SANITARY EQUIPMENT AND SEWER BLOCKAGES. 5.10.1. shall comply with all sanitary and/or other bylaws affecting the LEASED PREMISES and shall keep and maintain all plumbing, sanitary and sewerage equipment, connections, pipes and drains of the LEASED PREMISES in good working order and condition, and shall at all times purge, cleanse, scour, keep and maintain in good sanitary condition all such drains and other sanitary arrangements including washbasins, sanitary fittings and urinals; 5.10.2. shall not cause or permit to be caused any obstruction or blockage of sewerage pipes, water pipes or drains in the BUILDING and shall remove and repair, at its cost, any obstruction or any blockage of any sewerage or water pipes or drains so caused. 5.11.1. shall not interfere with any airconditioning installations in the BUILDING or in the LEASED PREMISES (where these have been provided otherwise than by the TENANT in terms of sub-paragraph 5.11.2 hereof) and shall be liable for the cost of any damage caused by such interference. 5.11.2. shall not be entitled to install in or on any part of the LEASED PREMISES any airconditioning plant or unit without the prior written consent of the LANDLORD, which shall not be unreasonably withheld. 5.11.3. shall not have any claim against the LANDLORD arising out of any defect in or interruption of the operation of airconditioning in the LEASED PREMISES. 5.11.4. shall be solely responsible for keeping, maintaining and repairing, at its sole cost and expense, all individual airconditioning units installed in the LEASED PREMISES in working order during the currency of this lease, and the TENANT shall not have any claim against the LANDLORD arising out of any defect in or interruption in the operation of such units in the LEASED PREMISES.
AutoNDA by SimpleDocs
PLUMBING, SANITARY EQUIPMENT AND SEWER BLOCKAGES. The TENANT :- 8.9.1 shall comply with all sanitary and / or other by-laws affecting the LEASED PREMISES and shall keep and maintain all plumbing, sanitary and sewerage equipment, connections, pipes and drains of the LEASED PREMISES and any other portions of the BUILDINGS in respect of which the TENANT enjoys common facilities in good working order and condition, and shall, at all times, purge, cleanse, scour, keep and maintain in good sanitary condition all such drains and other sanitary arrangements, including washbasins, sanitary fittings and urinals ; 8.9.2 shall not cause or permit to be caused any obstruction or blockage of sewerage pipes, water pipes or drains in the BUILDINGS and shall remove and repair, at its own cost and expense, any obstruction or any blockage or any sewerage or water pipes or drains so caused ; 8.9.3 shall, if the LEASED PREMISES are provided with food preparation facilities such as cooker hoods, fat filters, extraction ducting and grease traps, regularly clean same according to the LANDLORD'S instructions.
PLUMBING, SANITARY EQUIPMENT AND SEWER BLOCKAGES. 5.10.1. shall comply with all sanitary and/or other bylaws affecting the LEASED PREMISES and shall keep and maintain all plumbing, sanitary and sewerage equipment, connections, pipes and drains of the LEASED PREMISES in good working order and condition, and shall at all times purge, cleanse, scour, keep and maintain in good sanitary condition all such drains and other sanitary arrangements including washbasins, sanitary fittings and urinals; 5.10.2. shall not cause or permit to be caused any obstruction or blockage of sewerage pipes, water pipes or drains in the BUILDING and shall remove and repair, at its cost, any obstruction or any blockage of any sewerage or water pipes or drains so caused.

Related to PLUMBING, SANITARY EQUIPMENT AND SEWER BLOCKAGES

  • Sanitary Facilities Construction (a) Closets shall be soundly constructed and roofed with weatherproof material. The floor of each closet shall be well drained and constructed of concrete, bricks and cement, or of other approved materials which shall be impervious to water. Every closet shall be well lighted by natural or artificial light and shall be ventilated. Each closet shall have a hinged door, capable of being fastened on the inside, lift seats/flaps and toilet paper. (b) If closets are of single unit construction (only to be used for the formwork process), not contained within a purpose built ablution block, privacy walls which shield the closet/s from outside view shall be installed. (Privacy walls are not required for purpose built ablution blocks eg ATCO huts). (c) Where practicable, toilets to be connected to sewerage before commencement of the job. (d) Closet/urinal location to be conveniently accessible to Employees, but not so close as to cause a nuisance to those persons. (e) Where necessary, portable water seal toilets of an approved standard are to be provided and regularly serviced. (f) Conveniently accessible closets and urinals are to be distributed every 5th floor on multi storey constructions. (g) Closets and urinals are to be washed daily with disinfectant and kept in clean, hygienic condition. (h) Adequate washing facilities, suitably drained, and wash basins/troughs are to be supplied with hot and cold running water. (i) Soap and towels are to be supplied.

  • Heating, Ventilation and Air Conditioning Landlord shall furnish to the Premises heating, ventilation and air-conditioning (“HVAC”) in accordance with the Design Standards set forth in Exhibit D during Ordinary Business Hours. Landlord shall have access to all air-cooling, fan, ventilating and machine rooms and electrical closets and all other mechanical installations of Landlord (collectively, “Mechanical Installations”), and Tenant shall not construct partitions or other obstructions which may interfere with Landlord’s access thereto or the moving of Landlord’s equipment to and from the Mechanical Installations. No Tenant Party shall at any time enter the Mechanical Installations or tamper with, adjust, or otherwise affect such Mechanical Installations. Landlord shall not be responsible if the HVAC System fails to provide cooled or heated air, as the case may be, to the Premises in accordance with the Design Standards by reason of (i) any equipment installed by, for or on behalf of Tenant, which has an electrical load in excess of the average electrical load and human occupancy factors for the HVAC System as designed, or (ii) any rearrangement of partitioning or other Alterations made or performed by, for or on behalf of Tenant. Tenant shall install, if missing, blinds or shades on all windows, which blinds and shades shall be subject to Landlord’s approval, and shall keep operable windows in the Premises closed, and lower the blinds when necessary because of the sun’s position, whenever the HVAC System is in operation or as and when required by any Requirement. Tenant shall cooperate with Landlord and shall abide by the rules and regulations which Landlord may reasonably prescribe for the proper functioning and protection of the HVAC System. Tenant acknowledges that the server room in the Premises currently has three heat pumps installed, being two 4-ton units, and one 2.5-ton unit (the “Existing Heat Pumps”). The 2.5-ton unit is currently connected and operational. Tenant shall determine whether it is satisfied with the condition of the Existing Heat Pumps and Landlord shall not have any responsibility or liability for the condition, operation, maintenance, repair or replacement of the Existing Heat Pumps. Tenant may operate the Existing Heat Pumps. Tenant shall be responsible for, and pay directly for, all necessary maintenance and repairs to the Existing Heat Pumps. Tenant shall reimburse Landlord monthly for the cost of all utility services used to operate the Existing Heat Pumps within 10 Business Days after receipt of Landlord’s invoice for such amount. Landlord may measure Tenant’s usage of such utility services by either a sub-meter or by other reasonable methods such as by temporary check meters or by survey. Tenant, at its cost, may replace the Existing Heat Pumps with one or more new heat pumps, provided, however, that the capacity of such replacement heat pump(s) shall not exceed the 10.5-ton capacity cooling capacity of the Existing Heat Pumps.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • System Upgrade Facilities Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.

  • Sanitary Sewer Provide a standard bubble map, as part of the plans, showing locations of numbered points, and a table with point number, northing and easting coordinates, description, and BL station for each point, for the following: ▪ all possible control as established or attained during preliminary survey, including but not limited to – section corners, property irons, intersection center-center irons, other set monuments ▪ benchmarks, including TBM set with preliminary survey ▪ center of manholes ▪ end of manhole stubs (when longer than five feet)

  • Heating, Ventilating and Air Conditioning General Office Area: The building shall be equipped with a combination heating, ventilation and air conditioning system. The system shall have ducted supply and return air. The space above the ceiling shall not be used as a supply or return plenum. The systems shall be sized in accordance with the

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • Installation, Maintenance, Testing and Repair Unless otherwise agreed in writing by the Parties, to the extent required by Applicable Law, Interconnection provided by a Party shall be equal in quality to that provided by such Party to itself, any subsidiary, affiliates or third party. If either Party is unable to fulfill its obligations under this Section 14.2, it shall notify the other Party of its inability to do so and will negotiate alternative intervals in good faith. The Parties agree that to the extent required by Applicable Law, the standards to be used by a Party for isolating and clearing any disconnections and/or other outages or troubles shall be at parity with standards used by such Party with respect to itself, any subsidiary, affiliate or third party.

  • System Upgrade Facilities and System Deliverability Upgrades Connecting Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities and System Deliverability Upgrades shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!