Project Substation Sample Clauses

Project Substation. The project substation will function to further increase the voltage to match the voltage of the BPA transmission system of 500kV. The project substation and associated interconnection infrastructure will include equipment such as free-standing steel switch-rack structures, one or more main power transformer(s)m breakers, power meters, and associated electrical lines.
Project Substation. The Project Substation will be an outdoor air insulated low profile design, single bus configuration located adjacent to the Xxxxxxx Substation, discussed below. It will consist of five 1250A grounding circuit breakers for the collector lines connected to the 34.5/230 kV step-up transformer. These breakers will be rated 38 kV maximum voltage 25 kA interrupting capability. A 34.5 kV disconnect switch will be installed on the 34.5 kV side of the main step-up transformer. The Project Substation circuit breakers, disconnect switches, PTs, CTs, and surge arresters will be connected by a combination of strain buses and rigid buses mounted on porcelain insulators, supported on steel structures. The Project Substation will include circuit breaker current transformers and bus- connected voltage transformers for metering and relaying. A 34.5 kV-120/240V station service transformer will supply power for the station service. All equipment, including fences, will be grounded to a sub-grade grounding system designed to IEEE 80 requirement. The substation area shall be covered with a 4 inch layer of # 2 crushed stone over a 6 inch layer of NYSDOT item 4 and will extend for a distance equal to 5 feet beyond the fence line.
Project Substation. A high-voltage substation connected to each Station Unit beginning at the high-voltage terminals of such Station Unit’s step-up transformer.
Project Substation. EPC Contractor shall design, procure and install the Project Substation located on the Site, which will incorporate Owner’s Transformer. The Project Substation shall generally consist of all civil foundation, structures, circuit breakers, switches, metering and instrumentation, relays and controls, arresters, transformers, control buildings, SCADA, telecommunications and appurtenant facilities and equipment.

Related to Project Substation

  • Project Site The “Project Site” is the place where the Work is being carried on.

  • Project 3.01. The Recipient declares its commitment to the objectives of the Project. To this end, the Recipient shall carry out the Project in accordance with the provisions of Article IV of the General Conditions.

  • Access to Project Site Redeveloper shall permit the representatives of the City to enter Project Site at any and all reasonable times, as the City may deem necessary for the purposes of this Redevelopment Agreement, including but not limited to work and inspection of all work being performed in connection with the construction of the Redeveloper Improvements. Similarly, the City shall permit Redeveloper such entry upon the public rights of way for such purposes. No compensation shall be payable nor shall any charges be made in any form by any party for the access or inspection provided for in this Section. The City’s right of access granted under this Section shall terminate upon issuance by the City of the Redeveloper’s Certificate of Completion of Redeveloper Improvements. Notwithstanding the above, Redeveloper shall not be relieved of the provisions contained in Chapter 14.29 of the Lincoln Municipal Code regarding the use of streets for private construction purposes.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Projects There shall be a thirty (30) km free zone around the projects excluding the Metro Vancouver Area. For local residents, kilometers shall be paid from the boundary of the free zone around the project. Workers employed by any contractor within an identified free zone who resides outside of that same free zone will be paid according to the Kilometer Chart from the project to their residence less thirty

  • Parking Facilities Alamo Colleges District shall make the existing parking facilities at the rented Facility available for the vehicular traffic and parking necessitated by the Organization’s Use of the rented Facility, on a non-exclusive basis, as specified at Exhibit A. MAXIMUM CAPACITY. Organization anticipates approximately the number of participants stated at Exhibit A and agrees to inform Alamo Colleges District of any significant changes five (5) business days in advance of a Use. Organization shall not admit a larger number of persons than can safely and freely move about the Facility. Alamo Colleges District shall notify Organization of the recommended capacity of the Facility and all decisions of Alamo Colleges District concerning questions arising under this Paragraph shall be final.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!