Submittal Format Sample Clauses

Submittal Format. ‌ 7 Submittal packages must have a unique alphanumeric identifier that remains with the package 8 and identifies each Submittal stage (e.g., Initial Design Submittal, Final Design Submittal, RFC
AutoNDA by SimpleDocs
Submittal Format. ‌ 19 Submittal packages must have a unique alphanumeric identifier that remains with the package 20 and identifies each Submittal stage (e.g., Initial Design Submittal, Final Design Submittal, RFC
Submittal Format. ‌ 12 Submittal packages must have a unique alphanumeric identifier that remains with the package 13 and identifies each Submittal stage (e.g., Initial Design Submittal, Final Design Submittal, 14 Release for ConstructionRFC Submittal, etc.). The alphanumeric identifier must remain constant 15 and track the design package through the life of the Project. 16 Developer shall submit all Submittal documents in hardcopy and electronic format as specified 17 in Table 110-12 unless otherwise specified in the Contract Documents. Table 110-12 Submittal Format Submittal Stage/Deliverable Hardcopy Electronic Paper 11x17 Native PDF Administrative Documents (e.g., PMP, Project Schedule) X X X Specifications, Technical Reports, Calculations, Modeling, Input and Output Files, etc. X X X Initial Design Submittal X X X Final Design Submittal X X X Release for ConstructionRFC Submittal X X X Final Design Documents Submittal X X X Shop and Working Drawings X X Request for Information X Design Changes X X Record Drawings X X X Other Governmental Entities, Utility Companies, and railroad submittalsSubmittals* X Note: * Developer shall determine the additional format requirements required by the applicable Governmental Entity, Utility Company, and/or railroad.
Submittal Format. ALL bid copies must be submitted in a sealed envelope or container with the OUTERMOST Container stating the address, telephone number, the RFPP number and title RFPP #24003 0000 Xxx Xxxx Drive Hanger Lease If you have an ACCGov Vendor Number please include it on the sealed envelope or container. If you do not know your vendor number, please email: xxxxxx@xxxxxx.xxx. If you do not have a vendor number but you are awarded this RFP, you will be invited to submit your vendor registration per the following instructions: xxxxx://xxx.xxxxxx.xxx/DocumentCenter/View/88465.
Submittal Format. All reports presenting data, analyses, and recommendations shall be prepared in a standard typed format for Contractor reports. All site drawings shall be legible and of engineering quality with sufficient detail to show interrelations of major features on the site map (i.e., north arrows, keys, scales, detailed legends, etc.). When drawings are required, data may be combined to reduce the number of drawings. The final report shall be provided in electronic (pdf) and paper format. The paper report shall consist of 8-1/2" by 11" pages with drawings folded, if necessary, to this size. A decimal paragraph system shall be used. A report title page shall identify the report title, the Contractor, the contract number, and the date. Submittals shall include incorporation of all previous review comments as well as the disposition of each comment. Response to comment packages shall include restating each comment and a detailed response. Below is a summary of the schedule for the required deliverables (typical): Deliverable Schedule Monthly Status Reports Monthly Daily Construction Reports Daily Weekly Summary of Construction Activities Weekly Project Management Plan (PMP) 60 Days after NTP* Construction Work Plan (CWP) 60 Days after NTP* Accident Prevention Plan/Site Safety and Health Plan (APP/SHPP) 60 Days after NTP* Sampling and Analysis Plan/Quality Assurance Project Plan (SAP/QAPP) 60 Days after NTP* Completion Report 60 Days after Completion *After NTP or task order award, as applicable.
Submittal Format. A. Conceptual Design-Submittal shall be one (1) full size drawing set of 22”x34” plans and PDF format.
Submittal Format. A. Design-Submittal No. 3 shall be one (1) full size drawing set of 22”x34” plans and PDF format.
AutoNDA by SimpleDocs
Submittal Format. Construction Document-Submittal Nos. 4a, 4b, 5a, 5b and 5c shall be submitted on. 22”x 34” for plans and 8.5”x11” double sided for Technical Specifications Manual. Bond prints of all plans will be included with each Submittal.
Submittal Format. Responses may not be longer than 20 pages (single side or 10 pages front and back), printed on 8 ½” x 11” paper and formatted in no smaller than 10 point font. Each section shall be labeled according to the sections below. All submitted material must only be bound with one staple in the upper left corner. Please no binders or any other type of spiral binding. Submittals must be able to fit into a 9 x 11 ½ inch folder.
Submittal Format. Design-Submittal Nos. 1a and 1b shall be submitted on min. 11”x17” and max. 30”x 42” for plans and 8.5”x11” double sided for outline specifications/reports.
Time is Money Join Law Insider Premium to draft better contracts faster.