Uninterruptible Power Supply Sample Clauses

Uninterruptible Power Supply. Customer shall provide a form of uninterruptible power for the fiber termination hardware and any Hunter facilities or equipment at the Customers location. If the Customer does not provide a uninterruptible power source, Hunter will provide one for the price listed below.
AutoNDA by SimpleDocs
Uninterruptible Power Supply. The Facility shall include one primary UPS system for the major plant control system. The UPS system shall be supplied with 30% spare capacity above calculated requirements. The output rating of the UPS system(s) shall be 120 V, single‑phase, 0.8 lagging PF to 1.0 PF, at 40°C ambient. UPS will be a true AC-DC-AC conversion type consisting of an inverter, with an alternate DC source supplied from the station service batteries, a rectifier and a static transfer switch. The static transfer switch will be connected to a second inverter as the alternate supply. Output of the UPS and the second inverter will connect to a manual maintenance bypass switch to the instrument AC panelboard.
Uninterruptible Power Supply. An online uninterruptible power supply (UPS) shall be required and it shall have adequate capacity to ensure that the protection, measurement and control operate without interruption for a minimum duration of at least 3 hours after loss of power supply. Seller shall submit the calculations in the determination of the sizing of the UPS. In the event of loss of the secured auxiliary supply, all the Seller‟s 22 kV Circuit Breakers shall be tripped until remedial actions are taken. The UPS system shall be installed on the Seller side of the Interconnection Boundary and be maintained accordingly by Seller. The UPS shall be equipped with a bypass switch/system that shall allow continuous operation during maintenance on the UPS. A separate UPS, than the one stated in the previous paragraph, shall be installed for all equipment used for the transmission of signals and commands (PLC, modem, router, etc.) between the Facilty and the CEB‟s Substation. All associated requirements mentioned in the previous paragraph of this section shall be applicable to this separate UPS.
Uninterruptible Power Supply. American Power Conversion Corporation Back-UPS ES 750 or Newpoint 750 VA Battery Backup or Equivalent (minimum 5 receptacles).
Uninterruptible Power Supply. The UPS shall be used to operate control system components including, PC's, and operator interfaces. The UPS shall have sufficient capacity, including 20% reserve capacity, to supply the control system and all other connected loads under worst case operating conditions, and for up to one hour without an AC power source, or to safety shut down the plant, whichever is the longer. An external manual bypass shall be provided to enable the UPS to be removed for repair.
Uninterruptible Power Supply. EDS shall not be liable for any failure or delay in the performance of its obligations under this Agreement if and to the extent such failure or delay is caused by a failure of the uninterruptible power supply existing at the Golden Data Center as of the Commencement Date, provided that EDS has taken reasonable steps to maintain such uninterruptible power supply. Coors acknowledges that EDS does not have an obligation to upgrade such uninterruptible power supply.
Uninterruptible Power Supply. Customer shall provide a form of uninterruptible power for the fiber termination hardware and any Hunter facilities or equipment at the Customers location. If the Customer does not provide a uninterruptible power source, Hunter will provide one for the price listed below. APC Uninterruptible Power Supply: $200.00 (one needed for each location)
AutoNDA by SimpleDocs
Uninterruptible Power Supply. American Power Conversion Corporation Back-UPS BE750G or Cyberpower OR750PFCLCD or equivalent (minimum 5 receptacles).

Related to Uninterruptible Power Supply

  • Power Supply The source of power for the VAS shall either be the vehicle battery or a rechargeable battery. Where provided, an additional rechargeable or non-rechargeable battery may be used. These batteries shall by no means supply energy to other parts of the vehicle electrical system.

  • All-Requirements Power Supply The service under which the Competitive Supplier provides all of the electrical energy, capacity, reserves, and ancillary services, transmission services, transmission and distribution losses, congestion management, and other such services or products necessary to provide firm power supply to Participating Consumers at the Point of Delivery.

  • Capacity Interconnection Rights Pursuant to and subject to the applicable terms of the Tariff, the Interconnection Customer shall have Capacity Interconnection Rights at the Point(s) of Interconnection specified in this Interconnection Service Agreement in the amount of 33.6

  • Water Supply The system may or may not meet state and local requirements. It is the right and responsibility of Buyer to determine the compliance of the system with state and local requirements. [For additional information on this subject, request the “Water Supply and Waste Disposal Notification” form.]

  • Reactive Power 1.8.1 The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all similarly situated generators in the New York Control Area on a comparable basis. 1.8.2 The NYISO is required to pay the Interconnection Customer for reactive power, or voltage support service, that the Interconnection Customer provides from the Small Generating Facility in accordance with Rate Schedule 2 of the NYISO Services Tariff.

  • Delivery Point The delivery point is the point of delivery of the Power Product to the CAISO Controlled Grid (the “Delivery Point”). Seller shall provide and convey to Buyer the Power Product from the Generating Facility at the Delivery Point. Title to and risk of loss related to the Power Product transfer from Seller to Buyer at the Delivery Point.

  • Variance Power The Fund is protected from obsolescence. If, in the sole judgment of the Board of Directors of the Foundation, the purposes for which the Fund was created ever become unnecessary, incapable of fulfillment, or inconsistent with the charitable needs of the community served by the Foundation, the Foundation’s Board of Directors shall modify any restriction or condition on the use or distribution of the income and principal of the Fund.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Delivery Points ‌ Project water made available to the Agency pursuant to Article 6 shall be delivered to the Agency by the State at the delivery structures established in accordance with Article 10.

  • Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None (2) In the event that, in accordance with the Interconnection Construction Service Agreement, Interconnection Customer has exercised the Option to Build, it is hereby permitted to build in accordance with and subject to the conditions and limitations set forth in that Section, the following portions of the Transmission Owner Interconnection Facilities which constitute or are part of the Customer Facility: None Ownership of the facilities built by Interconnection Customer pursuant to the Option to Build shall be as provided in the Interconnection Construction Service Agreement.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!