Ambient conditions. 4.1.1. The ambient temperature is between 0 °C and 45 °C.
AutoNDA by SimpleDocs
Ambient conditions. 3.1.1. During the test, the test cell temperature shall be between 293 K and 303 K (20 °C and 30 °C). The absolute humidity (H) of either the air in the test cell or the intake air of the engine shall be such that:
Ambient conditions. 2.1.3.1. Ambient condition indoor
Ambient conditions. 3.3.2.1. The ambient temperature shall be between 5 C (278 K) and 35 C (308 K) and the barometric pressure between 91 kPa and 104 kPa. The relative humidity shall be less than 95 per cent.
Ambient conditions. Each Plant shall be designed and constructed to take account of the following ambient conditions:
Ambient conditions. All pipes, materials and equipment shall be in every respect suitable for storage, installation, use and operation in the conditions of temperature, humidity and The PH and water quality appertaining in Jordan. Atmospheric temperature in Jordan varies between -10˚C and 50 ˚C.
Ambient conditions. The test shall be conducted under the ambient conditions laid down in this section. The ambient conditions become ‘extended’ when at least one of the temperature or altitude conditions is extended. The factor for extended conditions as defined in paragraph 10.5. shall only be applied once even if both conditions are extended in the same time period. Notwithstanding the opening paragraph of this section, if a part of the test or the entire test is performed outside of extended conditions, the test shall be invalid only when final emissions as calculated in Annex 11, are greater than the applicable emission limits. The conditions are as follows: Moderate altitude conditions Altitude lower or equal to 700 meters above sea level. Extended altitude conditions Altitude higher than 700 meters above sea level and lower or equal to 1300 meters above sea level. Moderate temperature conditions Greater than or equal to 273.15 K (0 °C) and lower than or equal to 308.15 K (35 °C). Extended temperature conditions Greater than or equal to 266.15 K (– 7 °C) and lower than 273.15 K (0 °C) or greater than 308.15 K (35 °C) and lower than or equal to 311.15 K (38 °C).
AutoNDA by SimpleDocs
Ambient conditions. The bus must be having proven design suitably modified to the climatic & operational conditions, infrastructure and road conditions prevailing in the Project Area. Typical operating conditions could be temperature range of 0o to 50oC, humidity levels from 5% to 100%, and altitude up to 300 m. Concessionaire is strongly advised to ensure that buses are able to meet the severe temperature, water, humidity, height from mean sea level, rain fall and dust storm conditions of Project Area during operation.
Ambient conditions. 1 Temperature, Humidity and Substrate Moisture Content Levels:
Ambient conditions. Ambient conditions including room temperature and humidity are defined as from 18 to 28 °C @ 50%, respectively.