Cable Pulling Sample Clauses

Cable Pulling. The CONTRACTOR will pull the cable to the manufacturer-approved specifications into a direct buried or underground innerduct or conduit system. Cable pulling eye shall be employed for pulls over 300 feet. The use of a Xxxxxm grip is acceptable for pulling cable through duct, however the central strength member and/or Kevlar shall be woven into and secured onto the grip on these pulls. The maximum allowable pulling tension shall not exceed the cable manufacturer's allowable tension - normally 600 pounds. A dynamometer shall be used to provide a warning before the maximum tension is reached. Swivels and breakaways between the cable pulling eye and the pull line set for the maximum tension shall be used during pulling operations. Cable feeders and equipment capable of maintaining a steady continuous pull shall be used. Where feasible, continuous cable pulls shall not be made through more than two 90- degree bends or more than a total of 180 degrees in conduit bends. However, when this is not possible, care should be taken to ensure that the maximum pulling tension is not exceeded. When it is not possible to locate the pulling apparatus adjacent to the vault, a "C" vault sheaf shall be used. Where the hand-hole or vault opening does not permit the use of 28 inch diameter sheaves, a quadrant block shall be used to ensure a dynamic bending radius of at least 20 feet. A cable feeder shall be used to protect and guide the cable into the duct. Where an extension section is required, its nozzle end shall be placed in the xxxl end of the main section. The cable feeder also shall be used to feed lubricant onto the moving cable. In sections where the cable shall be pulled in two directions, the flexible inner-duct used for cable protection shall serve as the cable feeder and the pull line from the inner-duct shall be fed through the cable feeder before the connection is made between the line and the cable. A marker consisting of several turns of friction tape on the pull line shall be placed 20 feet from the cable end. This marker shall be used to indicate when the cable is about to enter the manhole. Before starting the pull, the equipment shall be checked carefully to minimize the chance of interruption once pulling has started. The cable reel shall be inspected to ensure there are no factory reel defects, exposed nails, splinters, or similar hazards that could cause cable damage. The proper wrapping of the cable at the factory shall be verified. A pulling speed of 8...
AutoNDA by SimpleDocs
Cable Pulling. 1.4.1 The Requesting Licensee shall provide SingTel with no less than five (5) Business Days of notice prior to cable pulling between the designated Lead-in Manhole or Roof Space and the Co-Location Space.

Related to Cable Pulling

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • CLEC Provided Splitter – Line Sharing 3.4.1 Freedom may at its option purchase, install and maintain central office POTS splitters in its collocation arrangements. Freedom may use such splitters for access to its customers and to provide digital line subscriber services to its customers using the High Frequency Spectrum. Existing Collocation rules and procedures and the terms and conditions relating to Collocation set forth in Attachment 4- Central Office shall apply.

  • Casual Loading (e) Superannuation contributions are to be made for periods when Employees are on:

  • Merchant Transmission Facilities “Controllable A.C. Merchant Transmission Facilities” shall mean transmission facilities that (1) employ technology which Transmission Provider reviews and verifies will permit control of the amount and/or direction of power flow on such facilities to such extent as to effectively enable the controllable facilities to be operated as if they were direct current transmission facilities, and

  • SLEEPING CAPACITY/DISTURBANCES Tenant and all other occupants of the premises will be required to vacate the premises and forfeit the rental fee and security deposit for any of the following: Occupancy exceeding the sleeping capacity of the property, using the premises for any illegal activity, causing damage to the premises rented or to any of the neighboring properties and any other acts that interfere with neighbors' right to quiet enjoyment of their premises. HOLD HARMLESS None of iTrip Vacations, Sea Oats Vacation Property Management, Inc. or the owner of the premises assume risk, responsibility or any liability for, and the Tenant hereby releases, waives, relinquishes and discharges iTrip Vacations, Sea Oats Vacation Property Management, Inc., the owner of the premises and all directors, officers, employees, agents or other representatives of such parties from, any (i) loss, damage, illness, injury or exposure to COVID-19, other viruses or the flu to persons or their personal property that occurs during their stay on the premises; (ii) any inconveniences, damage, loss or injury arising from any temporary defects or stoppage in supply of water, gas, cable service, internet service, electricity or plumbing or (iii) any inconveniences, damage, loss or injury arising from or due to weather conditions, insects, natural disasters, acts of God, or other reasons beyond their control. POOL & PATIO If the premises include a private or community pool (including hot tubs), then the Tenant hereby acknowledges that the premises they have reserved include a community pool and the undersigned agrees and acknowledges that the community pool and patio/deck can be dangerous areas, that the deck/patio can be slippery when wet, and that injury may occur to anyone who is not careful. With full knowledge of the above facts and warnings, the undersigned Tenant accepts and assumes all risks involved to Tenant and all of Tenant's guests in or related to the use of the private or community pool (including hot tubs) and patio areas.

  • Manual Disconnect Switch 5.1 U.L.1741 Listed, inverter-based Tier 1 customer-owned renewable generation systems do not require a customer-installed manual disconnect switch.

  • Outdoor Lighting 3.8.1 Lighting shall be directed to driveways, parking areas, loading area, building entrances and walkways and shall be arranged so as to divert the light away from streets, adjacent lots and buildings.

  • Fast Food Outlets This proposal does not seek to interfere with the existing Fast Food Agreement.

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins.

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.2.1 Local circuit switching capability is defined as: (A) line-side facilities, which include, but are not limited to, the connection between a loop termination at a main distribution frame and a switch line card; (B) trunk-side facilities, which include, but are not limited to, the connection between trunk termination at a trunk-side cross-connect panel and a switch trunk card; (C) switching provided by remote switching modules; and (D) all features, functions, and capabilities of the switch, which include, but are not limited to: (1) the basic switching function of connecting lines to lines, line to trunks, trunks to lines, and trunks to trunks, as well as the same basic capabilities made available to BellSouth’s customers, such as a telephone number, white page listings, and dial tone; and (2) all other features that the switch is capable of providing, including but not limited to customer calling, customer local area signaling service features, and Centrex, as well as any technically feasible customized routing functions provided by the switch. Any features that are not currently available but are technically feasible through the switch can be requested through the BFR/NBR process.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!