Certifications/Qualifications Required Sample Clauses

Certifications/Qualifications Required. (1) Inspectors shall meet the qualification requirements of 1 RCNY 101-06, Appendix A under the following Special Inspection Category: (a) “Mechanical Systems” for testing of high-pressure-gas piping; and/or (b) “Welding” for inspection of welding and welding operations. (2) Radiographic / Non-Destructive Testing (NDT): (a) Current American Society for Non-Destructive Testing (ASNT) Level II Certified by current employer to ‘SNT-TC-1A’ or by ASNT Control Certified Program (ACCP) in the relevant NDT method, OR (b) ASNT Level II or III certified to ACCP in the relevant NDT Method.
AutoNDA by SimpleDocs
Certifications/Qualifications Required i) Current Certification as an ACI Concrete Field Testing Technician-Grade I and at least one year of batch plant inspection experience.
Certifications/Qualifications Required i) ACI Concrete Laboratory Testing Technician, Level I or II for the tests being performed. ii) Supervisors or Laboratory Directors shall be qualified as follows: (1) For projects under the jurisdiction of the New York City Department of Buildings, the supervisor, or laboratory director, shall be qualified in accordance with 1RCNY 101-07, Paragraph (6)(ii). (2) For projects performed under the Building Code of New York State, the supervisor or Laboratory Director shall be a licensed design professional and further qualified in accordance with ASTM E329.
Certifications/Qualifications Required i) For projects governed by the New York State Building Code, masonry field inspectors shall meet the following qualification requirements, with the following clarifications:
Certifications/Qualifications Required i) For projects governed by the Building Code of New York State, inspection of smoke control systems shall be provided by inspectors qualified as follows;
Certifications/Qualifications Required i) Applicability to be determined by the code enforcement official based on the specific requirements of the work determined to be “unusual in nature” as defined by the Code.
Certifications/Qualifications Required. (1) Inspectors shall meet the qualification requirements of 1 RCNY 101-06, Appendix A under the following Special Inspection Category: (a) “Wall Panels, Curtain Walls and Veneers” (b) “Masonry”, as applicable
AutoNDA by SimpleDocs
Certifications/Qualifications Required. (1) Inspectors shall meet the qualification requirements of 1 RCNY 101-06, Appendix A under the following Special Inspection Categories, as applicable to the system being inspected: (a) “Mechanical Systems” (b) “Heating Systems
Certifications/Qualifications Required. (1) Inspectors shall meet the qualification requirements of 1 RCNY 101-06, Appendix A under the following Special Inspection Categories, as applicable: (a) “Standpipe Systems and Sprinkler Systems
Certifications/Qualifications Required. (1) Windows shall be field tested by an AAMA-accredited testing laboratory, in accordance with the following: (2) ASTM E783, Field Measurement of Air Leakage Through Installed Exterior Windows and Doors. (3) ASTM E1105, Field Determination of Water Penetration of Installed Exterior Windows, Curtain Walls and Doors by Uniform or Cyclic Static Air Pressure Difference.