MEASUREMENT AND VERIFICATION The goal of this task is to report the benefits resulting from this project. Project team may use in- house expertise of the project demonstration site or use third party vendor for measurement and verification (M&V) of greenhouse gas and energy consumption reduction. The Recipient shall: • Enter into agreement with M&V subcontractor per Task 1.9. • Coordinate site visits with the M&V subcontractor at the demonstration sites. • Develop M&V protocol for pre-installation measurement (and calculations) following Section II.B.2 of the grant solicitation manual2: o Electric, natural gas and/or other fossil fuel consumption and greenhouse gas emissions (use appropriate emissions factor from Attachment 8 of the grant solicitation) of the equipment/process/system(s)/sub-system(s) that are to be upgraded and/or replaced and/or modified. o If necessary, ensure installation of sub-metering equipment and data loggers for pre/post data analysis. • Prepare and provide a detailed Measurement and Verification Plan for project demonstration sites to include but not be limited to: o A description of the monitoring equipment and instrumentation which will be used. o A description of the key input parameters and output metrics which will be measured. o A description of the M&V protocol and analysis methods to be employed. • Perform three months (or shorter period as approved in writing by the CAM) of pre- installation measurements (and calculations) based on the M&V protocol for pre-install • Prepare and provide a Pre-Installation Measurement and Verification Findings Report for each demonstration site that includes M&V protocol, pre-install measurements (and calculations), analysis, and results performed in this task. • Develop M&V protocol for Post-Installation measurements (or calculations) of: o Electric, natural gas and/or other fossil fuel consumption and greenhouse gas emissions (use appropriate emissions factor from Attachment 8 of the grant solicitation) of the equipment/process/system(s)/sub-system(s) that will be upgraded and/or replaced and/or modified ⚫ Perform 12 months (or shorter period as approved in writing by the CAM) of post- installation measurements based on M&V protocol for post-installation. • Provide a summary of post-installation M&V progress in Progress Report(s) (see subtask 1.5) which shall include but not be limited to: o A narrative on operational highlights from the reporting period, including any stoppages in operation and why; and o A summary of M&V findings from the reporting period. • Analyze post-installation electrical, natural gas and/or other fossil fuel consumption and greenhouse gas emissions. • Prepare and provide a Post-Installation Measurement and Verification Findings Report for each demonstration site that includes M&V protocol, pre and post install measurements (and calculations), analysis, and results performed in this task. Results should at a minimum report on the reduction of electricity, natural gas and/or other fossil fuel usage and reductions of greenhouse gas emissions that directly result from this project. 2GFO-18-903, Food Production Investment Program, California Energy Commission, November 2018 xxxxx://xxx.xxxxxx.xx.xxx/contracts/GFO-18-903/ o Provide all key assumptions used to estimate and determine energy and greenhouse gas reductions (and additions, if applicable). o Provide all key assumptions used to estimate projected benefits, including targeted market sector (e.g., population and geographic location), projected market penetration, baseline and projected energy use and cost, operating conditions, emission reduction calculations, and benefits to disadvantaged communities. Products: • Measurement and Verification Plan (draft and final) • Pre-Installation Measurement and Verification Findings Report (draft and final) • Post-Installation Measurement and Verification Findings Report(s) (draft and final)
Litigation Reporting If Contractor is served with a pleading or other document in connection with an action before a court or other administrative decision making body, and such pleading or document relates to this Participating Addendum or may affect Contractor’s ability to perform its obligations under this Participating Addendum, Contractor shall, within 10 days after being served, notify the State of such action and deliver copies of such pleading or document to the State’s primary contact identified in §5 of the Participating Addendum .
Evaluation Report 20.5.4.1 The summary evaluation report shall be prepared by the Faculty Evaluation Committee and administrative evaluator(s) and shall include each evaluator’s individual rating. The summary evaluation report shall take into account the results of each of the evaluation components (Section 20.5.3) in order to arrive at an overall rating. When the committee and the administrative evaluator(s) cannot reach an agreement as to the overall rating, the report must include written explanation.
Evaluation Reports Where a formal evaluation of an employee's performance is carried out, the employee shall be provided with a copy to read and review. Provision shall be made on the evaluation form for an employee to sign it. The form shall provide for the employee's signature in two (2) places, one indicating that the employee has read and accepts the evaluation, and the other indicating that the employee disagrees with the evaluation. The employee shall sign in one of the places provided within seven (7) calendar days. No employee may initiate a grievance regarding the contents of an evaluation report unless the signature indicates disagreement with the evaluation. The employee shall receive a copy of the evaluation report at the time of signing. An evaluation report shall not be changed after an employee has signed it, without the knowledge of the employee, and any such changes shall be subject to the grievance procedure.
Utilization Reports Both the Contractor and Subcontractor shall complete Quarterly Utilization Reports (or similar type documents containing the same information) and submit them to the Contracting Officer and to the Bureau within ten (10) business days at the end of each quarter. This information will be used to determine the actual dollar amount paid to Subcontractor and will also serve as a record of fulfillment of Contractor’s Small Diverse Business and Small Business Commitments. If there was no activity during the quarter, then the form must be completed by stating “No activity in this quarter.” A late fee of $100.00 per day may be assessed against the Contractor if its Utilization Report is not submitted in accordance with the schedule above.
Testing/Trouble Reporting 1.15.1 TWTC will be responsible for testing and isolating troubles on Network Elements. TWTC must test and isolate trouble to the AT&T network before reporting the trouble to the Network Elements Customer Wholesale Interconnection Network Services (CWINS) Center. Upon request from AT&T at the time of the trouble report, TWTC will be required to provide the results of the TWTC test which indicate a problem on the AT&T network. Version: 4Q06 Standard ICA 11/30/06
Project Monitoring Reporting Evaluation 1. The Project Implementing Entity shall monitor and evaluate the progress of the Project and prepare Project Reports in accordance with the provisions of Section 4.08(b) of the General Conditions and on the basis of indicators agreed with the Association. Each such Project Report shall cover the period of one fiscal year, and shall be furnished to the Association not later than sixty (60) days after the end of the period covered by such report.
Measurement and Billing The Parties shall measure Interconnection in accordance with this Section 4.6 and xxxx in accordance with Article XXVII and this Section 4.6.
Implementation Report Within 90 days after the Effective Date, Xxxxx shall submit a written report to OIG summarizing the status of its implementation of the requirements of this IA (Implementation Report). The Implementation Report shall, at a minimum, include:
Compliance Verification (a) The subrecipient shall periodically interview a sufficient number of employees entitled to DB prevailing wages (covered employees) to verify that contractors or subcontractors are paying the appropriate wage rates. As provided in 29 CFR 5.6(a)(6), all interviews must be conducted in confidence. The subrecipient must use Standard Form 1445 (SF 1445) or equivalent documentation to memorialize the interviews. Copies of the SF 1445 are available from EPA on request.