Network and Physical Security Requirements Sample Clauses

Network and Physical Security Requirements. Kronologic will: − install and maintain an industry standard firewall to protect Data, − regularly install security patches on the network for the Services, − ensure that authentication to the Services’ network web front-end is encrypted, − where applicable, use and regularly update anti-malware prevention tools, − maintain a credential management process which includes assigning a unique ID to each person with access to the Services with password complexity and change requirements, − utilize multi-factor authentication for the Kronologic workforce, − track access to systems, generate and store audit trail and logs to help identify malicious activity, − regularly test efficiency and health of security controls, systems and processes, − maintain a policy that addresses information security, − restrict physical access to systems containing Customer Data, − protect data backups from unauthorized access.
AutoNDA by SimpleDocs
Network and Physical Security Requirements 

Related to Network and Physical Security Requirements

  • Data Security Requirements Without limiting Contractor’s obligation of confidentiality as further described in this Contract, Contractor must establish, maintain, and enforce a data privacy program and an information and cyber security program, including safety, physical, and technical security and resiliency policies and procedures, that comply with the requirements set forth in this Contract and, to the extent such programs are consistent with and not less protective than the requirements set forth in this Contract and are at least equal to applicable best industry practices and standards (NIST 800-53).

  • Security Requirements 7.1 The Authority will review the Contractor’s Security Plan when submitted by the Contractor in accordance with the Schedule (Security Requirements and Plan) and at least annually thereafter.

  • Federal Medicaid System Security Requirements Compliance Party shall provide a security plan, risk assessment, and security controls review document within three months of the start date of this Agreement (and update it annually thereafter) in order to support audit compliance with 45 CFR 95.621 subpart F, ADP System Security Requirements and Review Process.

  • New Hampshire Specific Data Security Requirements The Provider agrees to the following privacy and security standards from “the Minimum Standards for Privacy and Security of Student and Employee Data” from the New Hampshire Department of Education. Specifically, the Provider agrees to: (1) Limit system access to the types of transactions and functions that authorized users, such as students, parents, and LEA are permitted to execute; (2) Limit unsuccessful logon attempts; (3) Employ cryptographic mechanisms to protect the confidentiality of remote access sessions; (4) Authorize wireless access prior to allowing such connections; (5) Create and retain system audit logs and records to the extent needed to enable the monitoring, analysis, investigation, and reporting of unlawful or unauthorized system activity; (6) Ensure that the actions of individual system users can be uniquely traced to those users so they can be held accountable for their actions; (7) Establish and maintain baseline configurations and inventories of organizational systems (including hardware, software, firmware, and documentation) throughout the respective system development life cycles; (8) Restrict, disable, or prevent the use of nonessential programs, functions, ports, protocols, and services; (9) Enforce a minimum password complexity and change of characters when new passwords are created; (10) Perform maintenance on organizational systems; (11) Provide controls on the tools, techniques, mechanisms, and personnel used to conduct system maintenance; (12) Ensure equipment removed for off-site maintenance is sanitized of any Student Data in accordance with NIST SP 800-88 Revision 1; (13) Protect (i.e., physically control and securely store) system media containing Student Data, both paper and digital; (14) Sanitize or destroy system media containing Student Data in accordance with NIST SP 800-88 Revision 1 before disposal or release for reuse; (15) Control access to media containing Student Data and maintain accountability for media during transport outside of controlled areas; (16) Periodically assess the security controls in organizational systems to determine if the controls are effective in their application and develop and implement plans of action designed to correct deficiencies and reduce or eliminate vulnerabilities in organizational systems; (17) Monitor, control, and protect communications (i.e., information transmitted or received by organizational systems) at the external boundaries and key internal boundaries of organizational systems; (18) Deny network communications traffic by default and allow network communications traffic by exception (i.e., deny all, permit by exception); (19) Protect the confidentiality of Student Data at rest; (20) Identify, report, and correct system flaws in a timely manner; (21) Provide protection from malicious code (i.e. Antivirus and Antimalware) at designated locations within organizational systems; (22) Monitor system security alerts and advisories and take action in response; and (23) Update malicious code protection mechanisms when new releases are available.

  • Safety Requirements The Contractor shall comply with all Federal, State, and local safety laws and regulations applicable to the Work performed under this Agreement.

  • Accessibility Requirements Under Tex. Gov’t Code Chapter 2054, Subchapter M, and implementing rules of the Texas Department of Information Resources, the System Agency must procure Products and services that comply with the Accessibility Standards when those Products are available in the commercial marketplace or when those Products are developed in response to a procurement solicitation. Accordingly, Grantee must provide electronic and information resources and associated Product documentation and technical support that comply with the Accessibility Standards.

  • Facility Requirements 1. Maintain wheelchair accessibility to program activities according to governing law, including the Americans With Disabilities Act (ADA), as applicable. 2. Provide service site(s) that will promote attainment of Contractor’s program objectives. Arrange the physical environment to support those activities. 3. Decrease program costs when possible by procuring items at no cost from County surplus stores and by accepting delivery of such items by County.

  • Technical Security Controls 35 a. Workstation/Laptop encryption. All workstations and laptops that store PHI COUNTY 36 discloses to CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of 37 COUNTY either directly or temporarily must be encrypted using a FIPS 140-2 certified algorithm which 1 is 128bit or higher, such as AES. The encryption solution must be full disk unless approved by the 2 COUNTY.

  • City Requirements Design, construction, materials, sizing, other specifications, permitting, inspections, testing, documentation and furnishing of as-built drawings, and acceptance of completed infrastructure shall be in accordance with City Requirements. Design and construction shall be by professionals licensed in the state of North Carolina to do the relevant work. City approval of the design of the Improvements shall be required prior to construction, as set forth in City Requirements. If Developer is connecting to the County sewer system, the City may require Developer to furnish the contract providing for such connection.

  • Residency Requirements 1. All single first-year freshmen students are required to live in University housing for at least two academic semesters. All single students who have earned less than 30 credit hours and have not resided in University housing for two academic semesters are required to live on campus for two academic semesters. This policy does not apply to single first-year students who have been out of high school for more than one year, or to single first-year freshmen who live with their parents in Miami-Dade or Broward Counties. Neither does it apply to those students who, for disciplinary or administrative reasons, may be denied the privilege of continued residency on campus. 2. Undergraduate students residing in University housing must be regularly enrolled students of the University, taking a minimum of 12 credit hours each semester. Graduate students (when housed by exception) must carry a minimum of nine credit hours per semester. To apply and sign-up for University Village apartments, students must have 45 or more completed academic credits. In order to move into University Village, students must have 60 or more completed academic credits or have completed 4 academic semesters at the University and be achieving satisfactory academic progress as defined by the University Bulletin.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!