Overnight Travel For each full day of travel, all three meals are reimbursable. Per diems on the first and last day of a trip are governed as set forth below. Departure Day Depart before 12:00 noon Lunch and dinner Depart after 12:00 noon Return Day Dinner Return before 12:00 noon Breakfast Return between 12:00 noon & 7:00 p.m. Breakfast and lunch Return after 7:00 p.m.* Breakfast, lunch and dinner *7:00 p.m. is defined as direct travel time and does not include time taken to stop for dinner. The reimbursement rates for individual meals are calculated as a percentage of the full day per diem as follows: Breakfast 15% Lunch 25% Dinner 60%
Overnight Guests Any guest who remains in on-campus housing past 12:00am is considered an Overnight Guest. Overnight Guests under the age of 16 who are not enrolled are not permitted. No resident will be allowed more than two (2) Overnight Guests at one time (this number can be reduced during special events). Any Overnight Guest requires the approval of the roommate(s). No Overnight Guest may stay more than three (3) consecutive days without the permission of the roommate and the Hall Director. No individual may stay as an Overnight Guest in on-campus housing for more than 15 days total in a given semester. Persons who have been removed from on-campus housing for any reason may not return as Overnight Guests following their removal.
Overnight Trips If the Company determines that overnight travel is required, the employee will be reimbursed for expenses, which are supported by receipts as follows:
Overnight Delivery When delivered by an overnight delivery service, charges prepaid or charged to the sender’s account, notice is effective on delivery, if delivery is confirmed by the delivery service.
Telephone Service Notwithstanding any other provision of this Lease to the contrary:
Firm Point-To-Point Transmission Service “Non-Firm Point-To-Point Transmission Service” shall mean Point-To-Point Transmission Service under the Tariff that is reserved and scheduled on an as-available basis and is subject to Curtailment or Interruption as set forth in Tariff, Part II, section 14.7. Non-Firm Point-To-Point Transmission Service is available on a stand-alone basis for periods ranging from one hour to one month. Non-Firm Sale:
Transmission Service Point-To-Point Transmission Service provided under Part II of the Tariff on a firm and non-firm basis.
Laundry Service If the Government provides a laundry service at the incident base camp, the Contractor may utilize the service at no cost.
Warranty Service In Home Danby Products Limited PO Box 1778, Guelph, Ontario, Canada N1H 6Z9 Telephone: (000) 000-0000 FAX: (000) 000-0000 0-000-000-0000 04/17 Danby Products Inc. PO Box 669, Findlay, Ohio, U.S.A. 45840 Telephone: (000) 000-0000 FAX: (000) 000-0000 LIMITED IN-HOME APPLIANCE WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable. TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. First Year During the first twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser. To obtain Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance Service requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service must be performed by a qualified service technician. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all obligations of Danby under this warranty shall be void. Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certif ied for warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he responsibility of the purchaser. Nothing within this warranty shall imply that Xxxxx will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 xxxxx per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts. An adequately sized 3 phase “wye” wound step down transformer shall be provided to supply 208/120-volt, 3 phase power, for lighting, general service receptacles and dedicated computer based office equipment. Dedicated, isolated ground circuits shall be supplied from separate isolated ground power distribution panel(s). Lighting circuits shall be supplied from separate lighting panel(s). Panels shall have 20% spare capacity and be complete with 10% spare breakers of each size, but no less than 1 spare. No more than 4 duplex receptacles shall be connected to any single 20-amp dedicated isolated ground circuit or general service circuit.