Pulsation Sample Clauses

Pulsation. Production equipment upstream of the Receipt Points shall be designed and operated in a manner that will not interfere with acceptable measurement standards. If such interference is detected, Gatherer shall notify Shipper and Shipper shall have sixty (60) Days to correct or cause to be corrected the problems causing measurement errors due to pulsation, vibration, or harmonic wave distortion caused by compressors, pumps, or other production equipment upstream of the Receipt Points. Either Party shall have the right to conduct pulsation or Square Root Error (SRE) tests on orifice meters as they deem prudent, at the testing Party’s sole risk and expense. Inaccuracies greater than or equal to one half of one percent (0.5%) SRE at typical operating conditions that are found to be the result of pulsation, vibration, or harmonic wave distortion caused by compressors, pumps, or other production equipment upstream of the Receipt Points will be corrected. EXHIBIT 10.1
AutoNDA by SimpleDocs
Pulsation. The Parties shall design, install, operate and maintain their respective equipment in such a manner that pulsation-induced measurement error is minimized. Pulsation-induced error shall not exceed one quarter of one percent (0.25%) of square root error (SRE). Either party has the right to request a test of the orifice meter facility. If SRE is found to exceed the limit stated above, the party responsible for the creation of the SRE must have a plan for the elimination of the SRE within thirty (30) days and equipment installed or modified to correct SRE in a reasonable amount of time, not to exceed six (6) months. Pulsation errors determined by the use of a square root error indicator manufactured under a license for the Southern Gas Association are to be used only for the purpose of determining SRE and are not to be used for adjusting measured volumes.
Pulsation. If Gas pulsation problems occur upstream of the Xxxxxxx Receipt Points, Producers, or their designee, shall take the reasonable and customary industry adopted steps necessary to mitigate such pulsation. If Gas pulsation occurs downstream of the Xxxxxxx Receipt Points, Gatherer, or its designee, shall take the reasonable and customary industry adopted steps necessary to mitigate such pulsation
Pulsation. Production equipment upstream of the Receipt Points will be designed and operated in a manner that will not interfere with acceptable measurement standards. If such interference is detected, Gatherer will notify Producers and they will have sixty (60) Days to correct, or cause to be corrected, the problems causing measurement errors due to pulsation, vibration, or harmonic wave distortion caused by compressors, pumps, or other production equipment SPECIFIC TERMS IN THIS EXHIBIT HAVE BEEN REDACTED BECAUSE CONFIDENTIAL TREATMENT FOR THOSE TERMS HAS BEEN REQUESTED. THE REDACTED MATERIAL HAS BEEN SEPARATELY FILED WITH THE SECURITIES AND EXCHANGE COMMISSION, AND THE TERMS HAVE BEEN MARKED AT THE APPROPRIATE PLACE WITH TWO ASTERISKS (**). upstream of the Receipt Points. Either Party will have the right to conduct pulsation or Square Root Error (SRE) tests on orifice meters as they deem prudent, at the testing Party’s sole risk and expense. Inaccuracies greater than or equal to one half of one percent (0.5%) SRE at typical operating conditions that are found to be the result of pulsation, vibration, or harmonic wave distortion caused by compressors, pumps, or other production equipment upstream of the Receipt Points will be corrected.
Pulsation. Production equipment upstream of the Receipt Points shall be designed and operated in a manner that will not interfere with acceptable measurement standards. If such interference is detected, Gatherer shall notify Shipper and Shipper shall have sixty (60) Days to correct or cause to be corrected the problems causing measurement errors due to pulsation, vibration, or harmonic wave distortion caused by compressors, pumps, or other production equipment upstream of the Receipt Points. Either Party shall have the right to conduct pulsation or Square Root Error (SRE) test on orifice meters as they deem prudent, at the testing Party’s sole risk and expense. Inaccuracies greater than or equal to one half of one percent (0.5%) SRE at typical operating conditions that are found to be the result of pulsation, vibration, or harmonic wave distortion caused by compressors, pumps, or other production equipment upstream of the Receipt Points will be corrected. ​ ​ ​ ANCHOR SHIPPER GAS GATHERING AGREEMENT Exhibit H AMS AS GATHERER ​ EPSILON ENERGY USA, INC. AS SHIPPER ​ ​ ​ ​ EXHIBIT I GAS QUALITY SPECIFICATIONS Receipt Point Specifications. All Gas tendered by Shipper for Gatherer at the Receipt Point(s) shall be merchantable, and unless expressly waived in writing by Xxxxxxxx, shall conform to all of the most stringent quality specifications of any downstream Transporter(s); however, in no event shall the quality be more stringent than the specifications set forth below unless otherwise required and permitted herein. At a base pressure of fourteen and seventy-three hundredths (14.73) psia and a base temperature of sixty degrees Fahrenheit (60° F), such Gas shall not contain more than:
Pulsation. To maintain effective measurement at each Delivery Point, Seller or its representative shall use reasonable efforts to operate its pumping facilities to minimize any pulsation effects on the subsequent NGL measurement.

Related to Pulsation