Reactive Load Sample Clauses

Reactive Load. Customer shall control the amount of reactive load imposed on Dominion’s Facilities. 8.5.1 Customer shall control reactive load at Delivery Points within the same ranges as Dominion controls reactive load for Dominion’s own retail load. As of the effective date of this Agreement, such ranges are as specified below. 8.5.1.1 For all of Customer’s Delivery Points within a single Planning Zone where the Delivery Point is at 69 kV or greater, Customer shall maintain an aggregate power factor within such Planning Zone of not less than 97.3 percent (lagging). 8.5.1.2 For all of Customer’s Delivery Points within a single Planning Zone where the Delivery Point is at less than 69 kV, Customer shall maintain an aggregate power factor within such Planning Zone at not less than 99.0 percent (lagging). 8.5.1.3 The calculation of the Customer’s monthly power factor, and any applicable reactive power charges, shall be in accordance with the Service Agreement for Network Integration Transmission Service under which the Customer purchases Network Integration Transmission Service in the Dominion Zone, as such may change from time to time. The Dominion Zone shall be as defined in the PJM OATT. 8.5.2 Through the Administrative Committee, the Parties shall work to develop a plan to bring the Customer’s Delivery Points within each Planning Zone into compliance with the power factor requirements of Section 8.5.1. 8.5.3 The Planning Zone of each Delivery Point shall be listed in the Delivery Point Catalog. The Planning Zones as used in determining compliance to this Section 8.5 may be revised by Dominion upon one year’s advance notice.
AutoNDA by SimpleDocs

Related to Reactive Load

  • Leave Loading The employer and the individual employee must have genuinely made the agreement without coercion or duress.

  • Annual Leave Loading During a period of annual leave an employee will receive a loading of 17.5 per cent calculated on the employee’s normal hourly rate of pay and the daily fares allowance if applicable. The loading will also apply to proportionate leave on lawful termination.

  • CLEC OUTAGE For a problem limited to one CLEC (or a building with multiple CLECs), BellSouth has several options available for restoring service quickly. For those CLECs that have agreements with other CLECs, BellSouth can immediately start directing traffic to a provisional CLEC for completion. This alternative is dependent upon BellSouth having concurrence from the affected CLECs. Whether or not the affected CLECs have requested a traffic transfer to another CLEC will not impact BellSouth's resolve to re-establish traffic to the original destination as quickly as possible.

  • Under-Frequency and Over Frequency Conditions The New York State Transmission System is designed to automatically activate a load- shed program as required by the NPCC in the event of an under-frequency system disturbance. Developer shall implement under-frequency and over-frequency relay set points for the Large Generating Facility as required by the NPCC to ensure “ride through” capability of the New York State Transmission System. Large Generating Facility response to frequency deviations of predetermined magnitudes, both under-frequency and over-frequency deviations, shall be studied and coordinated with the NYISO and Connecting Transmission Owner in accordance with Good Utility Practice. The term “ride through” as used herein shall mean the ability of a Generating Facility to stay connected to and synchronized with the New York State Transmission System during system disturbances within a range of under-frequency and over-frequency conditions, in accordance with Good Utility Practice and with NPCC Regional Reliability Reference Directory # 12, or its successor.

  • Floor Load Tenant shall not place a load upon any floor of the Premises that exceeds 50 pounds per square foot “live load”. Landlord reserves the right to reasonably designate the position of all Equipment which Tenant wishes to place within the Premises, and to place limitations on the weight thereof.

  • Contract Amount Compensation amount(s), when stated in this Bid Specifications, shall not be construed as either the maximum or minimum amount which Department shall be obligated to accept as the result of this Bid Specifications or any Agreement entered into as a result of this Bid Specifications.

  • Total Contract Amount The contract total shall not exceed $350,000. Pricing shall be per Exhibit E attached.

  • Bandwidth the amount of data (quantified as “Mbps” or “Gbps”) made available to Customer as specified in a Service Order.

  • Shift Differential A. Shift differential will be $.60 cents per hour. B. Employees eligible for shift differential are those whose work shift begins before 6:00 a.m. or ends on or after 7:00 p.m. and are scheduled by their supervisor for a total shift of at least six (6) hours in duration. This shift differential shall not apply to those employees who have requested and have been granted flexible work scheduling.

  • Traffic Measurement and Billing over Interconnection Trunks 6.1 For billing purposes, each Party shall pass Calling Party Number (CPN) information on at least ninety-five percent (95%) of calls carried over the Interconnection Trunks. 6.1.1 As used in this Section 6, “Traffic Rate” means the applicable Reciprocal Compensation Traffic rate, Measured Internet Traffic rate, intrastate Switched Exchange Access Service rate, interstate Switched Exchange Access Service rate, or intrastate/interstate Tandem Transit Traffic rate, as provided in the Pricing Attachment, an applicable Tariff, or, for Measured Internet Traffic, the FCC Internet Order. 6.1.2 If the originating Party passes CPN on ninety-five percent (95%) or more of its calls, the receiving Party shall xxxx the originating Party the Traffic Rate applicable to each relevant minute of traffic for which CPN is passed. For any remaining (up to 5%) calls without CPN information, the receiving Party shall xxxx the originating Party for such traffic at the Traffic Rate applicable to each relevant minute of traffic, in direct proportion to the minutes of use of calls passed with CPN information. 6.1.3 If the originating Party passes CPN on less than ninety-five percent (95%) of its calls and the originating Party chooses to combine Reciprocal Compensation Traffic and Toll Traffic on the same trunk group, the receiving Party shall xxxx the higher of its interstate Switched Exchange Access Service rates or its intrastate Switched Exchange Access Services rates for all traffic that is passed without CPN, unless the Parties agree that other rates should apply to such traffic. 6.2 At such time as a receiving Party has the capability, on an automated basis, to use such CPN to classify traffic delivered over Interconnection Trunks by the other Party by Traffic Rate type (e.g., Reciprocal Compensation Traffic/Measured Internet Traffic, intrastate Switched Exchange Access Service, interstate Switched Exchange Access Service, or intrastate/interstate Tandem Transit Traffic), such receiving Party shall xxxx the originating Party the Traffic Rate applicable to each relevant minute of traffic for which CPN is passed. If the receiving Party lacks the capability, on an automated basis, to use CPN information on an automated basis to classify traffic delivered by the other Party by Traffic Rate type, the originating Party will supply Traffic Factor 1 and Traffic Factor

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!