Solar Water Heating System Sample Clauses

Solar Water Heating System. The supply of the warm water for the showers in the Administration Building and Workshop Building shall to be arranged by solar-thermal plants. The plants shall be designed to cover the entire warm water requirement. The temporarily reheating by electric power is permissible only with the proof of economic efficiency. For planning and installation of the plants, VDI 6002 (solar drinking water heating) and DIN 1988 (drinking water installation) or equivalent international standard are to be followed. The stored drinking water volume is to be limited on max. 2,000 l. The quantity needed beyond that, is to be kept by the buffer storage of the solar plant. The plants shall compose the following basic components: ▪ insulated convectors certified according to the building specifications, including the mounting construction and the piping system; ▪ hydraulic module with pump plant and safety equipment, as well as controlling equipment; ▪ storage plant for drinking water for max. 2000 ltrs. made of stainless steel with insulation; ▪ buffer storage for solar water; ▪ drinking water connection with water treatment; ▪ disinfection equipment for drinking water; ▪ inoculation connection for the disinfection of the drinking water plant.‌‌
AutoNDA by SimpleDocs
Solar Water Heating System. Solar water heating systems shall be executed as shown on the drawings, complete with all solar collector units, piping, pumps, electrical connections, fittings, expansion tanks, supports, accessories and all civil works, etc. The collector units or panels are grouped into assemblies as shown on the drawings. Each of the units shall comply with the following requirements: Type: Liquid heating solar flat plate collector Aperture: Area: 1.18 SQ.M Glazing material: 4mm float glass (Outer) Non (Inner) Gross Dims Height: 10 cm Width: 75.4 cm Length: 175.4 cm Area 1.32 SQ.m. Weight (Empty) 52 kg Fluid hold up volume 3.4 LTRS Absorber Plate Material Unimetal steel fin-tubes Coating: Alkyd base flat finish Flow Path Crid parallel Gen. Desc: Network of 7 steel tubes pressed Omega – In into steel sheet. Tubes are in 10 cm spacing CC. Insulation: Under absorber plates: 4 cm rock wool board. Density 60 Kg/MCU. Coated with aluminum foil Headers: Galvanized steel pipe on inch diameter Absorptivity 85% Max. working pressure 60 PSI Max. test pressure 90 PSI Recommended Flow rate 0.45 GPM/SQ. M

Related to Solar Water Heating System

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • Network Resource Interconnection Service (check if selected)

  • One-Way Interconnection Trunks 2.3.1 Where the Parties have agreed to use One-Way Interconnection Trunks for the delivery of traffic from PCS to Verizon, PCS, at PCS’s own expense, shall:

  • SS7 Network Interconnection 9.7.1 SS7 Network Interconnection is the interconnection of Global Connection local signaling transfer point switches or Global Connection local or tandem switching systems with BellSouth signaling transfer point switches. This interconnection provides connectivity that enables the exchange of SS7 messages among BellSouth switching systems and databases, Global Connection local or tandem switching systems, and other third-party switching systems directly connected to the XxxxXxxxx XX0 network.

  • Interconnection Service Interconnection Service allows the Interconnection Customer to connect the Large Generating Facility to the Participating TO’s Transmission System and be eligible to deliver the Large Generating Facility’s output using the available capacity of the CAISO Controlled Grid. To the extent the Interconnection Customer wants to receive Interconnection Service, the Participating TO shall construct facilities identified in Appendices A and C that the Participating TO is responsible to construct. Interconnection Service does not necessarily provide the Interconnection Customer with the capability to physically deliver the output of its Large Generating Facility to any particular load on the CAISO Controlled Grid without incurring congestion costs. In the event of transmission constraints on the CAISO Controlled Grid, the Interconnection Customer's Large Generating Facility shall be subject to the applicable congestion management procedures in the CAISO Tariff in the same manner as all other resources.

  • Network Interconnection 26.1 Interconnection between the networks of different SERVICE PROVIDERs shall be as per National Standards of CCS No.7 issued from time to time by Telecom Engineering Centre (TEC) and also subject to technical feasibility and technical integrity of the Networks and shall be within the overall framework of interconnection regulations issued by the TRAI from time to time. However, if situation so arises, INTERCONNECTION with R2MF signaling may be permitted by LICENSOR.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • NETWORK INTERCONNECTION METHODS 64.1 This Section sets forth the terms and conditions for Network Interconnection Methods (NIMs) provided between CenturyLink and CLEC for the Interconnection Facilities established between the Parties’ networks. Additionally, this Section describes the physical architecture for the Interconnection of the Parties’ facilities and equipment required for the transmission and routing of Local Traffic, ISP-Bound Traffic, IntraLATA LEC Toll Traffic, VoIP-PSTN Traffic, Transit Traffic and Jointly Provided Switched Access Service Traffic.

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

Time is Money Join Law Insider Premium to draft better contracts faster.