System Unavailability Sample Clauses

System Unavailability. Failure of the system to provide a designated user access based on service level agreements or software/hardware problems within the contractors span of control.
AutoNDA by SimpleDocs
System Unavailability. Online Services may be unavailable when systems require maintenance or major unforeseen events occur, such as earthquakes, fires, floods, computer failures, interruptions in telephone service, electrical outages, civil unrestor riots, war, or acts or threatened acts of terrorism or other circumstances beyond our control. We shall have noliability for interruptions or delays in services due to systems unavailability. When unavailable, you may use our telephone banking system, an automated teller machine ("ATM"), customercontact center or a branch office to conduct your transactions.
System Unavailability. Failure of the system to provide a designated user access based on service level agreements or software/hardware problems within the Contractor’s span of control. System Function Response Time: Based on the specific sub function being performed, Record Search Time-the time elapsed after the search command is entered until the list of matching records begins to appear on the monitor.
System Unavailability. As measured within the CONTRACTOR’s information systems span of control, when a system user does not get the complete, correct full-screen response to an input command within three (3) minutes after depressing the “Enter” or other function key. TCA – Tennessee Code Annotated. TENNCARE – TENNCARE shall have the same meaning as “State.” TennCare or TennCare Program – The program administered by the single state agency, as designated by the state and CMS, pursuant to Title XIX of the Social Security Act and the Section 1115 research and demonstration waiver granted to the State of Tennessee and any successor programs.
System Unavailability. Should the Medicare network become unavailable for a period of time, the ANZ HealthPay terminal will display a message when you attempt to next process a claim. In this event, you may advise the claimant to lodge their claim through an alternative channel.
System Unavailability. As measured within the SE’s information systems span of control, when a system user does not get the complete, correct full-screen response to an input command within three (3) minutes after depressing the "Enter" or other function key.

Related to System Unavailability

  • Unavailability In the event that the Administrative Agent shall have determined in good faith (i) that U.S. dollar deposits in the principal amounts requested with respect to a Eurodollar Loan are not generally available in the London interbank Eurodollar market or (ii) that reasonable means do not exist for ascertaining the Eurodollar Rate, the Administrative Agent shall, as soon as practicable thereafter, give notice of such determination to the Borrowers and the Lenders. In the event of any such determination under clauses (i) or (ii) above, until the Administrative Agent shall have advised the Borrowers and the Lenders that the circumstances giving rise to such notice no longer exist, (A) any request by a Borrower for Eurodollar Loans shall be deemed to be a request for Base Rate Loans (or Absolute Rate Competitive Bid Loans, as the case may be), and (B) any request by a Borrower for conversion into or continuation of Eurodollar Revolving Loans shall be deemed to be a request for conversion into or continuation of Base Rate Loans.

  • Unavailability of Tenor of Benchmark Notwithstanding anything to the contrary herein or in any other Loan Document, at any time (including in connection with the implementation of a Benchmark Replacement), (A) if the then-current Benchmark is a term rate (including the Term SOFR Reference Rate) and either (1) any tenor for such Benchmark is not displayed on a screen or other information service that publishes such rate from time to time as selected by the Administrative Agent in its reasonable discretion or (2) the regulatory supervisor for the administrator of such Xxxxxxxxx has provided a public statement or publication of information announcing that any tenor for such Benchmark is not or will not be representative, then the Administrative Agent may modify the definition of “Interest Period” (or any similar or analogous definition) for any Benchmark settings at or after such time to remove such unavailable or non-representative tenor and (B) if a tenor that was removed pursuant to clause (A) above either (1) is subsequently displayed on a screen or information service for a Benchmark (including a Benchmark Replacement) or (2) is not, or is no longer, subject to an announcement that it is not or will not be representative for a Benchmark (including a Benchmark Replacement), then the Administrative Agent may modify the definition of “Interest Period” (or any similar or analogous definition) for all Benchmark settings at or after such time to reinstate such previously removed tenor.

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Availability of Utilities All utility services necessary for the construction of the Improvements will be available prior to the commencement of construction, and all utility services necessary for the proper operation of the Improvements for their intended purposes are available at the Leased Premises or will be available at the Leased Premises prior to the Final Disbursement Date, at commercially comparable utility rates and hook-up charges for the vicinity, including water supply, storm and sanitary sewer facilities, gas, electricity and telephone facilities. Lessee shall furnish evidence of such availability of utilities from time to time at Lessor's request.

  • Floor Loading Floor loading capacity shall be within building design capacity. Tenant may exceed floor loading capacity with Landlord’s consent, at Landlord’s sole discretion and must, at Tenant’s sole cost and expense, reinforce the floor as required for such excess loading.

  • Benchmark Unavailability Period Upon the Borrower’s receipt of notice of the commencement of a Benchmark Unavailability Period, the Borrower may revoke any pending request for a SOFR Borrowing of, conversion to or continuation of SOFR Loans to be made, converted or continued during any Benchmark Unavailability Period and, failing that, the Borrower will be deemed to have converted any such request into a request for a Borrowing of or conversion to Base Rate Loans. During a Benchmark Unavailability Period or at any time that a tenor for the then-current Benchmark is not an Available Tenor, the component of Base Rate based upon the then-current Benchmark or such tenor for such Benchmark, as applicable, will not be used in any determination of Base Rate.

  • Unavailability of Deposits or Inability to Ascertain, or Inadequacy of, LIBOR If on or prior to the first day of any Interest Period for any Borrowing of Eurodollar Loans:

  • Floor Load Tenant shall not place a load upon any floor of the Premises that exceeds 50 pounds per square foot “live load”. Landlord reserves the right to reasonably designate the position of all Equipment which Tenant wishes to place within the Premises, and to place limitations on the weight thereof.

  • Generator Subject to the provisions of this Section 29.36, Tenant shall be entitled to install, operate and maintain a generator and any other equipment related thereto, including, without limitation, a fuel system, wiring and shaft space (“Generator”) next to the Building at Tenant’s sole cost and expense (without paying any additional fee or rental to Landlord for the use thereof). Prior to the installation of the Generator, Tenant shall inspect the proposed location to determine a suitable location for the Generator, and Tenant shall submit written plans and specifications relative to the type, size and proposed location (including any proposed screening) of the Generator to Landlord for its review and written approval. Tenant shall be solely responsible for the cost of acquisition, installation, operation, and maintenance of the Generator; and Tenant shall install, maintain and operate the Generator in accordance with all federal, state, and local laws, statutes, ordinances, rules and regulations, including without limitation, obtaining and maintaining any and all permits, approvals and licenses required to install and operate the Generator by any governmental authority having jurisdiction. Landlord and Tenant agree that, upon the expiration of earlier termination of the Lease Term, Tenant shall not be required to remove the Generator, any associated cabling, wiring and screening or other improvements. Tenant shall not be entitled to grant or assign to any third party (other than a permitted assignee of Tenant’s rights under the Lease or a permitted subtenant relative to the Premises (or a portion thereof)) the right to use the Generator without Landlord’s prior written consent (which consent may be granted or withheld in Landlord’s discretion). Upon reasonable advance notice to Tenant (and provided Landlord reasonably coordinates with Tenant and provides an alternate source of backup generator capacity during said transition), Landlord shall be entitled to cause the Generator to be moved to another location near the Building, at Landlord’s cost and expense. Tenant shall pay all personal property taxes on the Generator. Tenant shall also pay any increases in the real property taxes of the Building due to the installation of the Generator within thirty (30) days of receipt of notice from Landlord which includes proof of such increase in taxes. Tenant’s indemnity obligations under Section 5.4.1.5 of the Lease, relating to the use of Hazardous Materials, shall apply to the use and operation of the Generator. Finally, Tenant’s insurance obligations under Section 10.3 of the Lease shall apply to the Generator.

Time is Money Join Law Insider Premium to draft better contracts faster.