BILL NO. 9 TILING The Tenderer is referred to the relevant Clauses in the separate document Model Preambles for Trades (2017 Edition) TENDERERS ARE TO NOTE THAT ALL WORK IS TO BE EXECUTED IN EXISTING BUILDINGS IN A COMBINATION OF NEW WORK, WORK IN PATCHES AND WORK IN SMALL QUANTITIES. SUPPLEMENTARY PREAMBLES Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster backing and descriptions of tiling on concrete floors etc shall be deemed to include 1:3 plaster bedding Quantity 12 2 Rate R Amount WALL TILING Allow a Prime Cost Amount of R170/m2 for ceramic tiles fixed with an approved adhesive to plaster (plaster elsewhere) and flush pointed with tinted jointing compond on: Walls. m2 Narrow widths. m2 FLOOR TILING Carried to Collection Section No. 2 Bill No. 9 Tiling 3 4 5 Allow a Prime Cost Amount of R170/m2 for ceramic floor tiles fixed with an approved adhesive on plaster bedding (bedding elsewhere) and flush pointed with tinted waterproof jointing compound on: Floors. m2 Narrow widths. m2 SUNDRIES Corner protectors, dividing strips, etc.: "Xxxx M-Trim PRE090" 9mm high white PVC round edge trim fixed with patent adhesive to external wall corners. m Carried to Collection Section No. 2 Bill No. 9 Tiling 5 1 10 R Section No. 2 Bill No. 9 Tiling COLLECTION Total Brought Forward from Page No. Carried Forward to Summary of Section No. 2 Section No. 2 Bill No. 9 Tiling Page No 88 89 R Amount
AutoNDA by SimpleDocs
BILL NO. 08 STRUCTURAL STEEL Pre-galvanised (Z450) structural steelwork (Grade 350W) 100 x 50 x 20 x 2mm Cold formed lipped channel including bolting to brickwork at 910mm centres. A1 : 2 C1 : 0 D1 : 3 G1 : 6 H1 : 0 m 11 BUILDING WORKS Bill No. 8 STRUCTURAL STEEL
BILL NO. 09 METALWORK 1 Single gate, size 900mm wide x 2050mm high, the leaf formed of 25 x 25 x 2mm wall thickness mild steel pipe framing all round and two horizontal intermediate rails with mitred and welded angles, the gate filled in with 12mm diameter mild steel bars welded, at each end, vertically to perimeter and intermediate framing at not exceeding 109mm centres, the leaf fitted with a 150mm long padbolt, the leaf to receive hasp and staple formed of 40 x 6mm mild steel flat bar welded onto frames and including fitting with two 50 x 10mm flat bar tee brackets and 16mm round bar pin hinges, twice bolted to wall with and including M16 x 95mm galvanised coach screws. No 6 A1 : 2 C1 : 1 D1 : 2 G1 : 1 H1 : 0 2 Mesh screen, size 2230mm wide x 2100mm high, formed of 32 x 32 x 2mm wall thickness square hollow section framing all round and two horizontal rails with mitred and welded angles, the framing covered with 50 x 50 x 4mm weld mesh tack welded on, and including fitting with two 50 x 10mm flat bar tee brackets and 16mm round bar pin hinges, twice bolted to wall with and including M16 x 95mm galvanised coach screws. No 1 A1 : 0 C1 : 1 D1 : 0 G1 : 0 H1 : 0 BUILDING WORKS
BILL NO. 8 METALWORK SUPPLEMENTARY PREAMBLES For preambles see "Specifications of materials and methods to be used - PW 371" PRESSED STEEL DOOR FRAMES 1,2mm Single rebated frames suitable for half brick walls: 1 Frame for door 813 x 2032mm high No 4 1,6mm Double rebated frames suitable for one brickwalls: 2 Frame for door 813 x 2032mm high No 2 STEEL WINDOWS, DOORS, ETC 3 Window type NE1, 533 x 654mm high including burglar bars No 5 4 Window type NE 7,1022 x 654mm high including burglar bars No 2 WELDED SCREENS, GATES, ETC Steel gates and frames: 5 Purpose made square hallow section mild steel security gate, size 813 x 2032mm High No 2 Sundires: 6 Purpose made protective steel cage to SHE-BIN No 2 Carried Forward to Summary of Section No. 2 Section No. 2 SFD4 Bill No. 8 METALWORK BVI CONSULTING ENGINEERS R
BILL NO. 1 Preliminaries The clauses in the abovementioned documents are hereinafter referred to by clause number and heading only Where any item is not relevant to this agreement such item is marked N/A signifying "not applicable" Where standard clauses or alternatives are not entirely applicable to this agreement such amendments, modifications, corrections or supplements as will apply are given under each relevant clause heading and such amendments, modifications, corrections or supplements shall take precedence notwithstanding anything to the contrary contained in the abovementioned documents.
BILL NO. 1 Preliminaries of building plans by any local or other authorities and the payment of any fees or charges related thereto F:......................... V:........................ T:........................ Item 13 Clause 13.0 - Setting out F:......................... V:........................ T:........................ Item 14 Clause 14.0 - Nominated subcontractors F:......................... V:........................ T:........................ Item
BILL NO. 1 ALTERATIONS The Tenderer is referred to the relevant Clauses in the separate document Model Preambles for Trades (2017 Edition) TENDERERS ARE TO NOTE THAT ALL WORK IS TO BE EXECUTED IN EXISTING BUILDINGS IN A COMBINATION OF NEW WORK, WORK IN PATCHES AND WORK IN SMALL QUANTITIES. SUPPLEMENTARY PREAMBLES Site inspection The Tenderer is advised to visit the site, inspect the existing premises and acquaint himself thoroughly with the nature of the work specified. Sizes and dimensions All sizes and dimensions stated herein are approximate and deemed only sufficient to identify the item of work concerned. No allowance for overbreak has been made to any of the adjoining structures, walls, finishes, etc., where removals or pockets occur (the nett opening size, etc., has been made good in later items of this bill where such making good has not been included with the item) and the Contractor must allow in his prices for making good any overbreak that may occur. Carried to Collection Section No. 2 Bill No. 1
AutoNDA by SimpleDocs
BILL NO. 9 PLASTERING Quantity Split: Note that the total quantity per each item is split into the various buildings and appears below each description as follows: A1 - DWG 04 - Staff Ablutions (2M2F1D) A2 - DWG 06 - Grade R Ablution (3R1T) A3 - DWG 14 - Male Ablutions (6B) A4 - DWG 35 - Female Ablutions (6G) MODEL PREAMBLES The tenderer is referred to the "Model Preambles for Trades 2008" for supplementary and comprehensive expansion of descriptions, appropriate provision for which shall be deemed to have been included in all relevant rates SCREEDS 1:3 Cement and sand screeds steel trowelled on concrete: 1 30mm Thick on floors. m2 107 A1 : 31 A2 : 24 A3 : 22 A4 : 30 INTERNAL PLASTER Cement plaster on substructure brickwork (pit walls): 2 On walls. m2 268 A1 : 84 A2 : 67 A3 : 31 A4 : 86 Cement plaster on superstructure brickwork: 3 On walls. m2 430 A1 : 132 A2 : 93 A3 : 86 A4 : 119 Carried Forward to Summary of Section No. 2 Section 2 Bill No. 9 Plastering
BILL NO. 9 PLASTERING Quantity Split: Note that the total quantity per each item is split into the various buildings and appears below each description as follows: A1 - DWG 04 - Staff Ablutions (2M2F1D) A2 - DWG 10 - Male Ablution (8B) A3 - DWG 17 - Female Ablutions (8G) MODEL PREAMBLES The tenderer is referred to the "Model Preambles for Trades 2008" for supplementary and comprehensive expansion of descriptions, appropriate provision for which shall be deemed to have been included in all relevant rates SCREEDS 1:3 Cement and sand screeds steel trowelled on concrete: 1 30mm Thick on floors. m2 97 A1 : 31 A2 : 29 A3 : 37 INTERNAL PLASTER Cement plaster on substructure brickwork (pit walls): 2 On walls. m2 258 A1 : 84 A2 : 59 A3 : 115 Cement plaster on superstructure brickwork: 3 On walls. m2 386 A1 : 132 A2 : 111 A3 : 143 Carried Forward to Summary of Section No. 2 Section 2 Bill No. 9 Plastering
BILL NO. 10 PLASTERING The Tenderer is referred to the relevant Clauses in the separate document Model Preambles for Trades (2017 Edition) TENDERERS ARE TO NOTE THAT ALL WORK IS TO BE EXECUTED IN EXISTING BUILDINGS IN A COMBINATION OF NEW WORK, WORK IN PATCHES AND WORK IN SMALL QUANTITIES. Quantity 11 2 Rate R Amount INTERNAL PLASTER One coat cement plaster mimimum 15mm thick (5:1) wood floated to receive tiles (elsewhere) including all labours on: Brick vertical surfaces (part on concrete). m2 Narrow widths. m2 Two coats cement plaster comprising one coat cement plaster minimum 15mm thick (5:1) steel floated and one finishing coat rhinolite including all labours on: Brick vertical surfaces (part on concrete). m2 Narrow widths. m2 Carried Forward to Summary of Section No. 2 Section No. 2 Bill No. 10 Plastering