Delivery Point / Interconnection Point definition
Delivery Point / Interconnection Point. ; shall mean the point(s) of connection(s) at which energy is delivered into the Grid System
Delivery Point / Interconnection Point means the point(s) of connection(s) at which energy is delivered into the Grid System, metering shall be at the 33 kV bus of substation of MSEDCL/Maharashtra State Electricity Transmission Company limited (MSETCL).
Delivery Point / Interconnection Point. /” Metering Point” shall mean the point at which energy is fed /deliver into the GRID Sub-station owned by UHBVN/DHBVN/HVPNL to which the solar power project is connected through a dedicated transmission line. Metering shall be done at this interconnection point where power is injected into. For interconnection with grid and metering, the Successful Bidder shall abide by the relevant and applicable regulations/Grid Code notified by HERC, Central Electricity Authority (Installation and Operation of Meters) Regulations, 2006 as amended and revised from time to time, or orders passed there under by the appropriate commission or CEA. All charges and losses relating to transmission of power from the project up to Delivery Point i.e substation (including but not limited to open access, transmission, wheeling, Unscheduled Interchange, Scheduling, Reactive power, SLDC charges etc.) as notified by the competent authority
More Definitions of Delivery Point / Interconnection Point
Delivery Point / Interconnection Point means the point(s) of connection(s) at which energy is delivered into the Grid System: metering shall be at the 33 kV bus of pooling substation of MSEDCL/Maharashtra State Electricity Transmission Company limited (MSETCL).
Delivery Point / Interconnection Point means the point /points at Sub-station owned by PSTCL (for intrastate projects) or CTU/Inter State Transmission Licensee (for interstate projects) to which the solar power project is connected through a dedicated transmission line to deliver the energy into grid system. Metering shall be done at low voltage bus bar of such substation. For interconnection with grid and metering, the Successful Bidder shall abide by the relevant and applicable regulations / Grid Code notified by PSERC, CERC, Central Electricity Authority (Installation and Operation of Meters) Regulations, 2006 as amended and revised from time to time, or orders passed there under by the appropriate commission or CEA. All charges and losses relating to transmission of power from the project up to Delivery Point (including but not limited to open access, transmission, wheeling, Unscheduled Interchange, Scheduling, Reactive power, RLDC /SLDC charges etc.) as notified by the competent authority /Appropriate Commission/Regulator shall be borne by the SPD. Further, all charges and losses beyond the Delivery Point through the ISTS up to Punjab periphery are exempted for all projects achieving CoD till 30.06.2023 for a period of 25 years from CoD to the extent specified in the Ministry of Power, Government of India Notification No. 23/12/2016-R&R Dated 15.01.2021. If the commissioning of the Project gets delayed beyond the applicable date of ISTS waiver due to Force Majeure event, the Ministry of Power, Government of India Notification No. 23/12/2016- R&R Dated 15.01.2021 provides for extension of the waiver. However, in case the waiver is not applicable for any reason whatsoever, including in cases where commissioning of the Project gets delayed beyond the applicable date of ISTS waiver, the liability of transmission charges and losses up to Punjab periphery would be that of the SPD. Further no change in charges / losses of ISTS shall be covered under Change in Law provision for any increase in tariff under this Agreement.
Delivery Point / Interconnection Point means the point at voltage level of 220 KV of the GNDTP Sub-station,PSTCL, Bathinda to which the solar power is to be evacuated through a dedicated transmission line to deliver the energy into the grid system. Metering shall be done at this interconnection point where power is injected into the grid system. For interconnection with grid and metering, the Successful Bidder shall abide by the relevant and applicable regulations/Grid Code notified by PSERC, Central Electricity Authority (Installation and Operation of Meters) Regulations, 2006 as amended and revised from time to time, or orders passed there under by the appropriate commission or CEA. All charges and losses relating to transmission of power from the project up to Delivery Point (including but not limited to open access, transmission, wheeling, Unscheduled Interchange, Scheduling, Reactive power, SLDC charges, grid connectivity charges etc.) as notified by the competent authority /PSERC shall be borne by the SPG.
Delivery Point / Interconnection Point means the point(s) of connection(s) at which energy is delivered into the Grid System i.e. AEGCL/APDCL substation, as applicable.
Delivery Point / Interconnection Point means the point of injection of the power from each of the rooftop solar system into JBVNL network. which shall be mutually agreed based on the interconnection system as provided under JSERC (Rooftop Solar PV Grid Interactive Systems and Net/Gross Metering) Regulations, 2015; and amendment thereof
Delivery Point / Interconnection Point. ; shall mean the point(s) of connection(s) at which energy is delivered into the Grid System i.e. AEGCL/APDCL substation, as applicable.
Delivery Point / Interconnection Point means the point of connection at nearest 33/11 kV substation of DISCOM/OPTCL;