Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.
Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety
Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.
Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.
Unbundled Sub-Loop Feeder 2.8.4.1 Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and cross-box (or other access point) that serves an end user location. 2.8.4.2 USLF utilized for voice traffic can be configured as 2-wire voice (USLF-2W/V) or 4-wire voice (USLF-4W/V). 2.8.4.3 USLF utilized for digital traffic can be configured as 2-wire ISDN (USLF-2W/I); 2-wire Copper (USLF-2W/C); 4-wire Copper (USLF-4W/C); 4-wire DS0 level loop (USLF-4W/D0); or 4-wire DS1 and ISDN (USLF-4W/DI). 2.8.4.4 USLF will provide access to both the equipment and the features in the BellSouth central office and BellSouth cross box necessary to provide a 2W or 4W communications pathway from the BellSouth central office to the BellSouth cross- box. This element will allow for the connection of Lightyear’s loop distribution elements onto BellSouth's feeder system.
California Independent System Operator Corporation a California nonprofit public benefit corporation having a principal executive office located at such place in the State of California as the ISO Governing Board may from time to time designate, initially 000 Xxxx Xxxxxx Xxxx, Xxxxxx, Xxxxxxxxxx 00000 (the “ISO”). The ISO Metered Entity and the ISO are hereinafter referred to as the “Parties”.
Commercially Useful Function A prime consultant can credit expenditures to a DBE subconsultant toward DBE goals only if the DBE performs a Commercially Useful Function (CUF). A DBE performs a CUF when it is responsible for execution of the work of a contract and carries out its responsibilities by actually performing, managing, and supervising the work involved. To perform a commercially useful function, the DBE must also be responsible, with respect to materials and supplies on the contract, for negotiating price, determining quality and quantity, ordering the material, and installing (where applicable) and paying for the material itself that it uses on the project. To determine whether a DBE is performing a commercially useful function, the Department will evaluate the amount of work subcontracted, industry practices, whether the amount the firm is to be paid under the contract is commensurate with the work it is actually performing and the DBE credit claimed for its performance of the work, and other relevant factors. A DBE will not be considered to perform a commercially useful function if its role is limited to that of an extra participant in a transaction, contract, or project through which funds are passed in order to obtain the appearance of DBE participation. In determining whether a DBE is such an extra participant, the Department will examine similar transactions, particularly those in which DBEs do not participate. If a DBE does not perform or exercise responsibility for at least 30 percent of the total cost of its contract with its own work force, or if the DBE subcontracts a greater portion of the work of a contract than would be expected on the basis of normal industry practice for the type of work involved, the Department will presume that the DBE is not performing a commercially useful function. When a DBE is presumed not to be performing a commercially useful function as provided above, the DBE may present evidence to rebut this presumption. The Department will determine if the firm is performing a CUF given the type of work involved and normal industry practices. The Department will notify the consultant, in writing, if it determines that the consultant’s DBE subconsultant is not performing a CUF. The consultant will be notified within seven calendar days of the Department’s decision. Decisions on CUF may be appealed to the ADOT State Engineer. The appeal must be in writing and personally delivered or sent by certified mail, return receipt requested, to the State Engineer. The appeal must be received by the State Engineer no later than seven calendar days after the decision of XXXX. XXXX’s decision remains in place unless and until the State Engineer reverses or modifies BECO’s decision. ADOT State Engineer will promptly consider any appeals under this subsection and notify the consultant of ADOT’s State Engineer findings and decisions. Decisions on CUF matters are not administratively appealable to USDOT. The BECO may conduct project site visits on the contract to confirm that DBEs are performing a CUF. The consultant shall cooperate during the site visits and the BECO’s staff will make every effort not to disrupt work on the project.
Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.
Registry Functions Activity Report This report shall be compiled in a comma separated-value formatted file as specified in RFC 4180. The file shall be named “gTLD-activity-yyyymm.csv”, where “gTLD” is the gTLD name; in case of an IDN-TLD, the A-label shall be used; “yyyymm” is the year and month being reported. The file shall contain the following fields: 01 operational-registrars number of operational registrars at the end of the reporting period 02 ramp-up-registrars number of registrars that have received a password for access to OT&E at the end of the reporting period 03 pre-ramp-up-registrars number of registrars that have requested access, but have not yet entered the ramp-up period at the end of the reporting period 06 web-whois-queries number of Web-based Whois queries responded during the reporting period, not including searchable Whois 09 dns-udp-queries-responded number of DNS queries received over UDP transport that were responded during the reporting period 10 dns-tcp-queries-received number of DNS queries received over TCP transport during the reporting period 11 dns-tcp-queries-responded number of DNS queries received over TCP transport that were responded during the reporting period 12 srs-dom-check number of SRS (EPP and any other interface) domain name “check” requests responded during the reporting period 13 srs-dom-create number of SRS (EPP and any other interface) domain name “create” requests responded during the reporting period 14 srs-dom-delete number of SRS (EPP and any other interface) domain name “delete” requests responded during the reporting period 15 srs-dom-info number of SRS (EPP and any other interface) domain name “info” requests responded during the reporting period 16 srs-dom-renew number of SRS (EPP and any other interface) domain name “renew” requests responded during the reporting period 17 srs-dom-rgp-restore-report number of SRS (EPP and any other interface) domain name RGP “restore” requests delivering a restore report responded during the reporting period 18 srs-dom-rgp-restore-request number of SRS (EPP and any other interface) domain name RGP “restore” requests responded during the reporting period 19 srs-dom-transfer-approve number of SRS (EPP and any other interface) domain name “transfer” requests to approve transfers responded during the reporting period 20 srs-dom-transfer-cancel number of SRS (EPP and any other interface) domain name “transfer” requests to cancel transfers responded during the reporting period 21 srs-dom-transfer-query number of SRS (EPP and any other interface) domain name “transfer” requests to query about a transfer responded during the reporting period 22 srs-dom-transfer-reject number of SRS (EPP and any other interface) domain name “transfer” requests to reject transfers responded during the reporting period 23 srs-dom-transfer-request number of SRS (EPP and any other interface) domain name “transfer” requests to request transfers responded during the reporting period 24 srs-dom-update number of SRS (EPP and any other interface) domain name “update” requests (not including RGP restore requests) responded during the reporting period 25 srs-host-check number of SRS (EPP and any other interface) host “check” requests responded during the reporting period 26 srs-host-create number of SRS (EPP and any other interface) host “create” requests responded during the reporting period 27 srs-host-delete number of SRS (EPP and any other interface) host “delete” requests responded during the reporting period 28 srs-host-info number of SRS (EPP and any other interface) host “info” requests responded during the reporting period 29 srs-host-update number of SRS (EPP and any other interface) host “update” requests responded during the reporting period 30 srs-cont-check number of SRS (EPP and any other interface) contact “check” requests responded during the reporting period 32 srs-cont-delete number of SRS (EPP and any other interface) contact “delete” requests responded during the reporting period 33 srs-cont-info number of SRS (EPP and any other interface) contact “info” requests responded during the reporting period 34 srs-cont-transfer-approve number of SRS (EPP and any other interface) contact “transfer” requests to approve transfers responded during the reporting period 35 srs-cont-transfer-cancel number of SRS (EPP and any other interface) contact “transfer” requests to cancel transfers responded during the reporting period 36 srs-cont-transfer-query number of SRS (EPP and any other interface) contact “transfer” requests to query about a transfer responded during the reporting period 37 srs-cont-transfer-reject number of SRS (EPP and any other interface) contact “transfer” requests to reject transfers responded during the reporting period 38 srs-cont-transfer-request number of SRS (EPP and any other interface) contact “transfer” requests to request transfers responded during the reporting period 39 srs-cont-update number of SRS (EPP and any other interface) contact “update” requests responded during the reporting period The first line shall include the field names exactly as described in the table above as a “header line” as described in section 2 of RFC 4180. No other lines besides the ones described above shall be included. Line breaks shall be <U+000D, U+000A> as described in RFC 4180. For gTLDs that are part of a single-instance Shared Registry System, the Registry Functions Activity Report may include the total contact or host transactions for all the gTLDs in the system. REGISTRATION DATA PUBLICATION SERVICES
Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)