Ceiling Systems Sample Clauses

Ceiling Systems. Ceiling systems must conform to fire, acoustics, maintenance and light reflection requirements. Gypsum Board ceiling suspension systems shall have 16 gauge, 1-1/2" main channels with 25 gauge 7/8" furring channels. Acoustical panel ceilings shall comply with ASTM E1264 Classifications and metal suspension systems with applicable ASTM C635 requirements. Suspend lighting fixtures independent of ceiling. Provide edge moldings, trim and acoustical sealant as required. Exposed face shall be white enamel. Grid spacing shall be 24" x 24". Lay in panels shall have an NRC range of .55 to .65, STC range of 35-39, light reflectance of LR-1, flame spread of 0-25 (ASTM E84) and nominal size of 24" X 24" X 5/8". Minimum ceiling height to be 9' nominal except in small rooms or limited areas which may be 8’. Provide unfaced mineral-fiber Sound Attenuation Blankets over ceiling systems where required to meet room to room sound transmission requirements. Provide painted, 5/8” gypsum board or veneer plaster ceilings in vestibules and restrooms. Provide means of access to ceiling system for maintenance of equipment or repair of system.
AutoNDA by SimpleDocs
Ceiling Systems. Dropped ceilings and or 2' x 2' lay in Donn Fineline Truss system above Mezzanine (Xxxxl 2) and open tile ceiling grid system or drywall ceiling where atrium area is to remain open without dropped ceiling appropriate provided in common rooms and building system. Tenant may elect to install a drop ceiling per lobby only. building standard as desired at underside of Mezzanine (Level 2) or in closed rooms. At north south exterior walls any Tenant installed ceilings are to terminate at drywall facia.
Ceiling Systems. (toilet rooms and related core areas) ---------------- (a) Acoustical ceilings: 24" x 24" x 5/8" fissured acoustical ceiling tile (similar to Acoustone Tegular Minatone) set in 15/16" exposed metal suspension system, white grid.

Related to Ceiling Systems

  • Building Systems The term “Building Systems” shall mean collectively the mechanical, electrical, plumbing, sanitary, sprinkler, heating, ventilation and air conditioning, security, life safety, elevator and other service systems or facilities of the Building and the finished ceiling and Building standard lighting fixtures in the Leased Premises, that are excluding any Premises Fixtures.

  • Ceilings 13.1 Lambdaboard ceilings, minimum 25mm thick with a width of 1220mm x 1800mm, skimmed with Plascon EZ Joint and EZ Skim system.

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Ceiling Company and its subcontractors will not affix, attach, or suspend any lighting fixtures, signs, or other fixtures or devices of any kind or nature from the ceiling above any of the Premises without the prior written approval of Authority.

  • Roof Any leaks or evidence of moisture? Yes No Unknown Type of Roof: Age Comments: Is there any existing fire retardant treated plywood? Yes No Unknown Comments:

  • Elevators Landlord shall provide passenger elevator service during normal business hours to Tenant in common with Landlord and all other tenants. Landlord shall provide limited passenger service at other times, except in case of an emergency.

  • Restrooms The restrooms, toilets, urinals, vanities and the other apparatus shall not be used for any purpose other than that for which they were constructed, and no foreign substance of any kind whatsoever shall be thrown therein. The expense of any breakage, stoppage or damage resulting from the violation of this rule shall be borne by the Tenant whom, or whose employees or invitees, shall have caused it.

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Plumbing fixtures and appliances shall be used only for the purposes for which designed, and no sweepings, rubbish, rags or other unsuitable material shall be thrown or deposited therein. Damage resulting to any such fixtures or appliances from misuse by a tenant or its agents, employees or invitees, shall be paid by such tenant.

Time is Money Join Law Insider Premium to draft better contracts faster.