Circuit Disconnects Switches and Enclosures Sample Clauses

Circuit Disconnects Switches and Enclosures. Enclosures shall be surface mounted type, unless otherwise noted, and of NEMA type 3R, waterproof. Disconnect Switches shall be DC or AC rated, as appropriate, with appropriate ampere ratings as required. They shall be UL listed and of NEMA type 3R, waterproof, meet proper AIC requirements, be correctly rated for DC or AC operation, as appropriate, and be “load-break” capable. Disconnects and enclosures must be properly supported and braced to Seismic zone requirements, where required. When used for disconnecting, disconnects for branch circuit protection shall be located per code. Switchgear must be accessible. The location of the disconnect switch may be acceptable as long as it is accessible 24/7 and approved by the local electric utility.
AutoNDA by SimpleDocs
Circuit Disconnects Switches and Enclosures. Enclosures shall be surface mounted type, unless otherwise noted, and of NEMA type 3R, waterproof. Disconnect Switches shall be heavy duty, DC or AC rated, as appropriate, with appropriate ampere ratings as required. They shall be UL listed and of NEMA type 3R, waterproof, meet proper AIC requirements, be correctly rated for DC or AC operation, as appropriate, and be “load-break” capable. Disconnects and enclosures must be properly supported and braced to Seismic zone requirements, where required. When used for disconnecting, disconnects for branch circuit protection shall be located as near as is practical to the supply end of the conductors being protected. Switchgear must be accessible. The location of the disconnect switch may be acceptable as long as it is accessible 24/7 and approved by PG&E. Fuses: All low voltage fuses for disconnects must be current limiting UL class J, RK1, or RK5 and of the appropriate voltage, delay or non delay characteristic, and current rating to provide both complete short circuit and overload protection per NEC sections regarding component protection. Fuses in the combiner boxes protecting PV string branch circuits must be UL class CC midget type, be in “shock-safe” type fuse holders “touch safe”, providing load break disconnect capabilities when changing fuses. Midget fuses and fuse holders used in these circuits must be fully DC rated and adequate DC short circuits withstand capability must be provided for all power situations including “back-fed” conditions. All fuses and other protective devices and holders must be engineered to safely protect system components under “worst case” expected field conditions including temperature extremes. PV panel strings must be individually protected from short circuit conditions that may originate within the panels themselves.

Related to Circuit Disconnects Switches and Enclosures

  • Manual Disconnect Switch 5.1 U.L.1741 Listed, inverter-based Tier 1 customer-owned renewable generation systems do not require a customer-installed manual disconnect switch.

  • Disconnection Upon termination of this Agreement, Developer and Connecting Transmission Owner will take all appropriate steps to disconnect the Developer’s Large Generating Facility from the New York State Transmission System. All costs required to effectuate such disconnection shall be borne by the terminating Party, unless such termination resulted from the non-terminating Party’s Default of this Agreement or such non-terminating Party otherwise is responsible for these costs under this Agreement.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Switching All of the negotiated rates, terms and conditions set forth in this Section pertain to the provision of local and tandem switching.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Connectivity User is solely responsible for providing and maintaining all necessary electronic communications with Exchange, including, wiring, computer hardware, software, communication line access, and networking devices.

  • Workstation/Laptop encryption All workstations and laptops that process and/or store DHCS PHI or PI must be encrypted using a FIPS 140-2 certified algorithm which is 128bit or higher, such as Advanced Encryption Standard (AES). The encryption solution must be full disk unless approved by the DHCS Information Security Office.

  • SS7 Network Interconnection 9.7.1 SS7 Network Interconnection is the interconnection of Global Connection local signaling transfer point switches or Global Connection local or tandem switching systems with BellSouth signaling transfer point switches. This interconnection provides connectivity that enables the exchange of SS7 messages among BellSouth switching systems and databases, Global Connection local or tandem switching systems, and other third-party switching systems directly connected to the XxxxXxxxx XX0 network.

  • Network Interconnection 26.1 Interconnection between the networks of different SERVICE PROVIDERs shall be as per National Standards of CCS No.7 issued from time to time by Telecom Engineering Centre (TEC) and also subject to technical feasibility and technical integrity of the Networks and shall be within the overall framework of interconnection regulations issued by the TRAI from time to time. However, if situation so arises, INTERCONNECTION with R2MF signaling may be permitted by LICENSOR.

  • Points of Interconnection and Trunk Types 2.1 Point(s) of Interconnection.

Time is Money Join Law Insider Premium to draft better contracts faster.