Comfort Stations Sample Clauses
The 'Comfort Stations' clause defines the requirements and responsibilities related to the provision and maintenance of restroom and sanitation facilities on a project site. Typically, this clause specifies the number, type, and cleanliness standards for toilets and wash areas that must be available to workers and sometimes visitors during the course of construction or an event. For example, it may require that portable toilets be installed at accessible locations and serviced regularly. The core function of this clause is to ensure health, safety, and compliance with regulations by providing adequate sanitary facilities for all personnel on site.
Comfort Stations. 1. The Contractor is required to provide a minimum of one(1) “comfort station” located within the Contractor’s authorized response zones that are accessible to on-duty field-based personnel 24/7. Staff quarters may be utilized as a comfort station if it meets the requirements herein. At a minimum, these facilities shall:
a. Be climate controlled (air conditioning and heat);
b. Have adequate and comfortable seating to accommodate a complete on-duty crew;
c. Have at least one operable toilet, sink, shower, microwave and refrigerator;
d. Have at least one desk and task chair;
e. Have data capability to enable patient care charting; and
f. Have adequate accommodations to meet the needs of nursing mothers.
2. Any changes to the locations of Contractor’s comfort stations or local headquarters will be subject to approval of MVEMSA Executive Director. Such approval shall not be unreasonably withheld.
Comfort Stations. The Contractor shall provide “comfort stations” located at strategic posts that are accessible to on-duty field-based personnel 24/7. At a minimum, these facilities shall: be climate controlled (air conditioning and heat); have adequate and comfortable seating to accommodate a complete on- duty crew; have at least one operable toilet, sink, and microwave as well as a desk, task chair; have data capability to enable patient care charting; and have adequate accommodations to meet the needs of nursing mothers.
Comfort Stations. Section 1: The Employer shall as far as practicable provide suitable comfort stations for the accommodations of operators while on duty. The company will post and maintain, on an annual basis, a current and updated list of comfort facilities which may be utilized by operators.
Comfort Stations. 1. The Contractor is required to provide a minimum of one(1) “comfort station” located within the Contractor’s authorized response zone that is accessible to on-duty field- based personnel 24/7. Staff quarters may be utilized as a comfort station if it meets the requirements herein. At a minimum, these facilities shall:
a. Be climate controlled (air conditioning and heat);
b. Have adequate and comfortable seating to accommodate a complete on-duty crew;
c. Have adequate beds to accommodate an on-duty 24-hour crew;
d. Have at least one operable toilet, sink, shower, microwave and refrigerator;
e. Have at least one desk and task chair;
f. Have data capability to enable patient care charting; and
g. Have adequate accommodations to meet the needs of nursing mothers.
2. Any changes to the locations of Contractor’s comfort stations or local headquarters will be subject to approval of the MCEMSA Executive Director. Such approval shall not be unreasonably withheld.
Comfort Stations. 2701 The City will provide a washroom facility in the immediate vicinity of the downtown bus mall.
Comfort Stations. Basic cleaning of the day use comfort stations twice daily at a frequency that is acceptable to County that will consist of disinfecting surfaces and toilet bowls and restocking of all needed paper products. County will provide the necessary supplies to County the bathrooms. Contractor will clean comfort stations to a standard acceptable to County.
Comfort Stations. 1. The Contractor is required to provide a minimum of two (2) “comfort stations” located at strategic posts that are accessible to on-duty field-based personnel 24/7. At a minimum, these facilities shall:
a. Be climate controlled (air conditioning and heat);
b. Have adequate and comfortable seating to accommodate a complete on-duty crew;
c. Have at least one operable toilet, sink, shower, microwave and refrigerator;
d. Have at least one desk and task chair;
e. Have data capability to enable patient care charting; and
f. Have adequate accommodations to meet the needs of nursing mothers.
2. Any changes to the locations of Contractor’s comfort stations or local headquarters will be subject to approval of MVEMSA Executive Director. Such approval shall not be unreasonably withheld.
