Equipment colocation requirements. 3.1.1. Customer’s equipment to be located in the Data Center must correspond with the requirements set forth in the given Agreement and must pass a professional inspection by the Executor’s technical specialists. In the event the equipment does not satisfy these requirements, the Executor may refuse to accept the equipment for colocation and require the equipment be modified or replaced. 3.1.2. Equipment must meet electrical safety requirements for equipment maintained in a telecommunications center. A power supply of 220 V and 50 Hz is provided in the Data Center. In the event the equipment to be installed has different power requirements, the Customer must provide the appropriate converters. The maximum power for each unit of equipment included in the Service cost is 300 W. The maximum power consumption for each unit of equipment must not exceed 3,000 W. This can be increased by ordering additional services. 3.1.3. When the Service is ordered, the Executor shall provide the Customer with a block of 5 (five) IPv4 addresses to one account; any number of these IPv4 addresses may be assigned to any of the servers (colocation or dedicated) on the account. A second block of five IP addresses shall be assigned to the Customer in the event the Customer orders a sixth server, etc. 3.1.4. Subnets are territorially distinct and thus calculated per region: for example, if a server is ordered in a data center in Moscow, the IPv4 address blocks already allocated to the Customer’s account in St. Petersburg and the Leningrad Area will not be factored in when the number of IPv4 address blocks to be allocated to the Customer’s account for Moscow are calculated. 3.1.5. One /64 IPv6 subnet shall automatically be allocated to each server. 3.1.6. Equipment must be capable of being connected to an Ethernet switch via T-wire (RJ-45 connector). In the event the equipment uses a different interface, the Customer shall provide all necessary media converters. Equipment must be able to connect at speeds from 10 Mbps to 1 Gbps in either half-duplex or full-duplex mode. The customer is obliged to configure the equipment’s network interfaces as instructed by technical personnel. 3.1.7. In addition to the equipment to be maintained, the Customer must provide all connection and mounting materials (power cables, fasteners, rails and brackets, etc.). In the event said materials are not provided, the Executor may refuse to accept the client’s equipment. 3.1.8. If necessary, the Executor sha...
AutoNDA by SimpleDocs

Related to Equipment colocation requirements

  • Installation requirements We (if we install the System) or our contractor (if we procure a contractor to install the System) must:

  • Construction Requirements (a) All Life and Safety and applicable Building Codes will be strictly enforced (i.e., tempered glass, fire dampers, exit signs, smoke detectors, alarms, etc.). Prior coordination with the Building Manager is required. (b) Electric panel schedules must be brought up to date identifying all new circuits added. (c) All electrical outlets and lighting circuits are to be properly identified. Outlets will be labeled on back side of each cover plate. (d) All electrical and phone closets being used must have panels replaced and doors shut at the end of each day’s work. Any electrical closet that is opened with the panel exposed must have a work person present. (e) All electricians, telephone personnel, etc. will, upon completion of their respective projects, pick up and discard their trash leaving the telephone and electrical rooms clean. If this is not complied with, a clean-up will be conducted by the building janitors and the general contractor will be back-charged for this service. (f) Welding or burning with an open flame will not be done without prior approval of the Building Manager. Fire extinguishers must be on hand at all times. (g) All “anchoring” of walls or supports to the concrete are not to be done during normal working hours (7:30 AM—6:00 PM, Monday through Friday). This work must be scheduled before or after these hours during the week or on the weekend. (h) All core drilling is not to be done during normal working hours (7:30 AM—6:00 PM, Monday through Friday). This work must be scheduled before or after these hours during the week or on the weekend. (i) All HVAC work must be inspected by the Building Engineer. The following procedures will be followed by the general contractor: i) A preliminary inspection of the HVAC work in progress will be scheduled through the Building Office prior to the reinstallation of the ceiling grid. ii) A second inspection of the HVAC operation will also be scheduled through the Building Office and will take place with the attendance of the HVAC contractor’s Air Balance Engineer. This inspection will take place when the suite in question is ready to be air-balanced. [***] = CONFIDENTIAL INFORMATION HAS BEEN OMITTED AND FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION. CONFIDENTIAL TREATMENT HAS BEEN REQUESTED WITH RESPECT TO THIS OMITTED INFORMATION. iii) The Building Engineer will inspect the construction on a periodic basis as well. (j) All existing thermostats, ceiling tiles, lighting fixtures and air conditioning grilles shall be saved and turned over to the Building Engineer.

  • GRADUATION REQUIREMENTS I understand that in order to graduate from the program and to receive a certificate of completion, diploma or degree I must successfully complete the required number of scheduled clock hours as specified in the catalog and on the Enrollment Agreement, pass all written and practical examinations with a minimum score of 80%, and complete all required clinical hours and satisfy all financial obligations to the College.

  • Encryption Requirements DST will not locally store Fund Data on any laptops or mobile devices (e.g., Blackberries, PDAs) managed by DST.

  • Design Requirements The DG Facility shall be installed in compliance with Wisconsin Administrative Code Chapter PSC 119.

  • Notification Requirements 1. If the Family Leave is foreseeable, the employee must provide the agency/department with thirty (30) calendar days notice of his or her intent to take Family Leave. 2. If the event necessitating the Family Leave becomes known to the employee less than thirty (30) calendar days prior to the employee's need for Family Leave, the employee must provide as much notice as possible. In no case shall the employee provide notice later than five (5) calendar days after he or she learns of the need for Family Leave. 3. For foreseeable leave due to a qualifying exigency, an employee must provide notice of the need for leave as soon as practicable, regardless of how far in advance such leave is foreseeable. 4. When the Family Leave is for the purpose of the scheduled medical treatment or planned medical care of a child, parent, spouse or registered domestic partner, the employee shall, to the extent practicable, schedule treatment and/or care in a way that minimizes disruption to agency/department operations.

  • Information Requirements The Company covenants that, if at any time before the end of the Effectiveness Period the Company is not subject to the reporting requirements of the Exchange Act, it will cooperate with any Holder and take such further reasonable action as any Holder may reasonably request in writing (including, without limitation, making such reasonable representations as any such Holder may reasonably request), all to the extent required from time to time to enable such Holder to sell Registrable Securities without registration under the Securities Act within the limitation of the exemptions provided by Rule 144 and Rule 144A under the Securities Act and customarily taken in connection with sales pursuant to such exemptions. Upon the written request of any Holder, the Company shall deliver to such Holder a written statement as to whether it has complied with such filing requirements, unless such a statement has been included in the Company’s most recent report filed pursuant to Section 13 or Section 15(d) of Exchange Act. Notwithstanding the foregoing, nothing in this Section 7 shall be deemed to require the Company to register any of its securities (other than the Common Stock) under any section of the Exchange Act.

  • Documentation Requirements ODM shall pay the MCP after it receives sufficient documentation, as determined by ODM, detailing the MCP’s Ohio Medicaid-specific liability for the Annual Fee. The MCP shall provide documentation that includes the following: 1. Total premiums reported on IRS Form 8963;

  • Application Requirements This application shall contain, as a minimum, a sketch showing the location of proposed facilities; a description, sketch, manufacturer’s brochure, etc. of the proposed facilities; and a description of the operation proposed. (11-28-90) 101. -- 199. (RESERVED)‌ 200. OPERATIONAL AGREEMENT.‌‌

  • General Education Requirements Students who intend to transfer to SUNY Buffalo State College with an A.A. or A.S. degree, will be considered as having fulfilled general education/Intellectual Foundations as long as they complete the 30 credits and 7 of 10 areas of SUNY-GER requirements prior to the start of their studies at SUNY Buffalo State College. Students should have successfully completed the SUNY-GER Basic Communication requirement with a grade of “C” or better, the mathematics requirement, and 5 of the remaining 8 categories. The student is responsible for fulfilling the SUNY Buffalo State College Diversity requirement.