Facility Unit Power Curve ("FPC Sample Clauses

Facility Unit Power Curve ("FPC. 2.1 From the Commercial Operation Date and for the entire period of the first Contract Year thereafter, the Seller shall measure and record the following information for the purpose of determining the FPC: 2.1.1 Gas flow rate measured prior to the engine or engines and the flares or vents (Nm3/hour); 2.1.2 Methane composition measured prior to the engine or engines and the flares or vents (%vol/vol); and 2.1.3 Energy Output of the Facility Unit, 2.2 The following requirements shall apply to the measurement and recording of the FPC Data: 2.2.1 the gas flow data must: 2.2.1.1 be measured using a gas flow meter mounted in such a location so as to enable the flow rate to all gas engines and flares or vents, to be measured in Nm3/hour. The location of the gas flow meter must be confirmed by the Independent Engineer, and may not be changed without the prior written agreement of both Parties; and 2.2.1.2 be grouped in bins to the nearest 5% of the nominal gas flow rate (being the gas flow rate required to achieve 100% of the Achieved Capacity of the Facility Unit); 2.2.2 the methane composition data must: 2.2.2.1 be measured by a gas composition analyser mounted in such location so as to enable the measurement of the methane composition to all gas engines and flares or vents, in % vol/vol. The location of the gas composition analyser must be confirmed by the Independent Engineer, and may not be changed without the prior written agreement of both Parties; and 2.2.2.2 be grouped in bins to the nearest 5%, and should cover the operational range of the Facility Unit; 2.2.3 the FPC Data shall be recorded as average values taken over 10 minute intervals; 2.2.4 the FPC Data shall be logged by a data logger on the Project Site and date stamped; and 2.2.5 the FPC Data shall be collected by the Facility Unit 's SCADA system. 2.3 The FPC Data shall be stored and analysed by the Seller in order to produce, for each recorded bin of methane composition, a FPC, which shall indicate the relationship between the Energy Output of the Facility Unit and the gas flowrate. 2.4 The FPC Data must be reported to the Buyer by the end of the first Contract Year following the Commercial Operation Date, and shall be verified by the Independent Engineer. The FPC Data shall be delivered in the following formats: 2.4.1 a hard copy of curves showing binned values only; 2.4.2 a hard copy scatter plot showing the individual average ten (10) minute values; and 2.4.3 all raw data obtained from the S...
AutoNDA by SimpleDocs

Related to Facility Unit Power Curve ("FPC

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • Facility Use The Employer shall allow individuals the use of gender- segregated facilities, such as restrooms, locker rooms, and dressing rooms that are consistent with that individual's gender expression or gender identity. In such facilities where undressing in the presence of others occurs, the Employer shall allow access to and use of a facility consistent with that individual's gender expression or gender identity.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • Generating Facility The Interconnection Customer’s device for the production of electricity identified in the Interconnection Request, but shall not include the Interconnection Customer’s Interconnection Facilities.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Facility Prudential is willing to consider, in its sole discretion and within limits which may be authorized for purchase by Prudential Affiliates from time to time, the purchase of Shelf Notes pursuant to this Agreement. The willingness of Prudential to consider such purchase of Shelf Notes is herein called the “Facility”. At any time, the aggregate principal amount of Shelf Notes stated in Section 1.2, minus the aggregate principal amount of Shelf Notes purchased and sold pursuant to this Agreement prior to such time, minus the aggregate principal amount of Accepted Notes (as hereinafter defined) which have not yet been purchased and sold hereunder prior to such time, is herein called the “Available Facility Amount” at such time. NOTWITHSTANDING THE WILLINGNESS OF PRUDENTIAL TO CONSIDER PURCHASES OF SHELF NOTES BY PRUDENTIAL AFFILIATES, THIS AGREEMENT IS ENTERED INTO ON THE EXPRESS UNDERSTANDING THAT NEITHER PRUDENTIAL NOR ANY PRUDENTIAL AFFILIATE SHALL BE OBLIGATED TO MAKE OR ACCEPT OFFERS TO PURCHASE SHELF NOTES, OR TO QUOTE RATES, SPREADS OR OTHER TERMS WITH RESPECT TO SPECIFIC PURCHASES OF SHELF NOTES, AND THE FACILITY SHALL IN NO WAY BE CONSTRUED AS A COMMITMENT BY PRUDENTIAL OR ANY PRUDENTIAL AFFILIATE.

  • Utilization Management Contractor shall maintain a utilization management program that complies with applicable laws, rules and regulations, including Health and Safety Code § 1367.01 and other requirements established by the applicable State Regulators responsible for oversight of Contractor.

  • Night Shift Differential Unit 12 employees who regularly work shifts shall receive a night shift differential as set forth below: A. Employees shall qualify for the first night shift pay differential of forty (40) cents per hour where four (4) or more hours of the regularly scheduled work shift falls between 6 p.m. and 12 midnight. B. Employees shall qualify for the second night shift pay differential of fifty (50) cents per hour where four (4) or more hours of the regularly scheduled work shift fall between 12 midnight and 6 a.m. C. A "regularly scheduled work shift" are those regularly assigned work hours established by the department director or designee.

  • Interconnection Customer Drawings Within one hundred twenty (120) days after the date of Initial Operation, unless the Interconnection Parties agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Transmission Provider and the Interconnected Transmission Owner final, “as-built” drawings, information and documents regarding the Customer Interconnection Facilities, including, as and to the extent applicable: a one-line diagram, a site plan showing the Customer Facility and the Customer Interconnection Facilities, plan and elevation drawings showing the layout of the Customer Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Customer Facility to the step-up transformers and the Customer Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Customer Facility. As applicable, the Interconnection Customer shall provide Transmission Provider and the Interconnected Transmission Owner specifications for the excitation system, automatic voltage regulator, Customer Facility control and protection settings, transformer tap settings, and communications.