Galvanized. Steel Sheet: Hot-dip, zinc-coated steel sheet complying with ASTM A 653/A 653M, G60 coating designation.
AutoNDA by SimpleDocs
Galvanized. Attic ventilation Ridge vents and vented soffit 12" overhang. Floor covering Commercial tile OWNER'S color choice-Office Vinyl base trims. All front office areas and rest rooms and shower areas. Floor covering Storage area, AI lab and utility room unpainted concrete. CONCRETE SPECIFICATIONS: Footings 6" x 36" Footing. Two horizontal rebar one below and one above grade. Vertical rebar to be 3' OC #3. Floors 3 1/2" to 4" thick All concrete to be 3500PSI concrete. One exterior 6' x 4' stoop areas with boot scraper. ELECTRICAL SPECIFICATIONS: 150 amp main interior 30 space panel to handle office area. 14-4' 4 tube fluorescent lights in office/AI area. 2-8' 2 tube fluorescent lights in boot room. 14-4' 2 tube fluorescent lights in bathroom, shower rooms, utility room and rest rooms. Incandescent lights in storage/utility areas. 1-exterior 175w security fixture at building entrance. All electrical outlets in shower areas and bathrooms to be ground fault interruption style. Standard residential wiring codes. PLUMBING SPECIFICATIONS: All plumbing to be PVC installed and vented as required to meet codes. Larger Shop drain with grate 12" x 12". Septic system and drain field by OWNER.
Galvanized. Attic ventilation Ridge vents and solid soffit 16" overhang. Air chamber inlet room As per standard specifications Curtain openings Screened but bird wire and interior base of hog panel galvanized. CONCRETE SPECIFICATIONS: Shallow footings 6" x 36" trenched. 24" x 6" perimeter stem wall with 3' OC vertical #3 rebar and 2 horizontal #3 rebar. Two horizontal rebar one below and one above grade. Vertical rebar to be 3' OC #3. Floors 3 1/2" to 4" thick Footings and pit walls and floors to be 3000PSI concrete and walk floors to be 3500PSI concrete. Wire mesh in all floor areas. All flush pits 16" -24" in depth sloped as per customer request. ELECTRICAL SPECIFICATIONS: 1-200 amp main interior 42 space panel. 100 22W McGill lights with florescent fixtures 4 rows of 12, 3 120V receptacles at Owner's option and 1-220V receptacles at Owner's option. Other electrical to ventilation, heaters and feed systems as required. All electrical in carlon or equal. PLUMBING SPECIFICATIONS: All plumbinx xx xe PVC. 2" PVC mainline. Soaker system in breeding squares. 6 runs of 1" high volume line with 4 drops per line. 2 boiler drains. 6" recycle line with one drop per pit.
Galvanized. Attic ventilation None and solid soffit with 6" overhang. Interior divide walls 2 x 8 T&G PVC Planking Hallway walls 2 x 4 Frame with PPD with 3/8" backing and SS nails and trims. CONCRETE SPECIFICATIONS: Shallow footings 8" x 12" Footer. 6" perimeter stem wall with 3' OC vertical #3 rebar and 2 horizontal #3 rebar. Two horizontal rebar one below and one above grade. Vertical rebar to be 3' OC #3. Floors 3 1/2" to 4" thick Footings and pit walls and floors to be 3000PSI concrete and walk floors to be 3500PSI concrete. All flush pits 16" in depth sloped as per customer request. ELECTRICAL SPECIFICATIONS: 1-200 amp main interior 42 space panel. 206 22W McGill lights 206-120V duplex receptacles at Owner's option and 2-220V receptacles at Owner's option. Other electrical to ventilation, heaters and feed systems as required. All electrical in carlon or equal. PLUMBING SPECIFICATIONS: All plumbinx xx xe PVC. One run of 2" mainline with pressure reducers for nipple drops and 1" hi-volume line with 4 drops per room.
Galvanized. ASTM A36, hot-dip zinc coated per ASTM A153, Class C or mechanically
Galvanized steel PV module support and racking system support posts shall be removed and disposed off-site by an approved facility.
Galvanized. Steel Items: Plated steel fasteners complying with ASTM B 633, Class Fe/Zn 25 for electrodeposited zinc coating.
AutoNDA by SimpleDocs
Galvanized after finishing the machining and marking, all parts of iron and steel will be galvanized through hot dip according to ASTM A 153 standard.
Galvanized steel 8D nails shall be used when placing structural-use panels, and galvanized steel 16D when placing furring strips. Galvanized self-tapping No.10 screws, 2 ½ inches long, with gimlet point should only be used when it becomes necessary to anchor a furring strip directly to corrugated roofing where there is not an existing rafter underneath to anchor into. All fasteners shall be installed every twenty-four (24) inches on center along the panel or furring strip. Corrugated roofs may require 3 1/2 –inch fasteners. The Contractor shall furnish and install fasteners of sufficient length to ensure a good connection.

Related to Galvanized

  • Western will as requested by the Manager oversee the maintenance of all books and records with respect to the investment transactions of the Fund in accordance with all applicable federal and state laws and regulations, and will furnish the Directors with such periodic and special reports as the Directors or the Manager reasonably may request.

  • Engines POSITION SERIAL NO. TOTAL HOURS TOTAL CYCLES HRS/CYCLES SINCE LAST SHOP VISIT Time Remaining to Next LIFE LIMITED PART REMOVAL PART NAME HOURS CYCLES MSN MSN

  • Underground Storage Tanks In accordance with the requirements of Section 3(g) of the D.C. Underground Storage Tank Management Act of 1990, as amended by the District of Columbia Underground Storage Tank Management Act of 1990 Amendment Act of 1992 (D.C. Code § 8-113.01, et seq.) (collectively, the “UST Act”) and the applicable D.C. Underground Storage Tank Regulations, 20 DCMR Chapter 56 (the “UST Regulations”), District hereby informs the Developer that it has no knowledge of the existence or removal during its ownership of the Property of any “underground storage tanks” (as defined in the UST Act). Information pertaining to underground storage tanks and underground storage tank removals of which the D.C. Government has received notification is on file with the District Department of the Environment, Underground Storage Tank Branch, 00 X Xxxxxx, X.X., Xxxxx Xxxxx, Xxxxxxxxxx, X.X., 00000, telephone (000) 000-0000. District’s knowledge for purposes of this Section shall mean and be limited to the actual knowledge of Xxxxxx Xxxxx, Property Acquisition and Disposition Division of the Department of Housing and Community Development, telephone no. (000) 000-0000. The foregoing is set forth pursuant to requirements contained in the UST Act and UST Regulations and does not constitute a representation or warranty by District.

  • Underground Tanks If underground or other storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any underground storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks.

  • Wash all machine-washable bedding, drapes, and clothing, on the hottest water temperature and dry on the highest heat setting. Items that cannot be washed must be taken to a dry cleaner who MUST be informed of the issue. You must safely discard ALL items that cannot be decontaminated.

  • Monument Signage Tenant shall have the right to have its logo listed on the monument sign for the Building (the “Monument Sign”), subject to the terms of this Section 23. The design, size and color of Tenant’s signage with Tenant’s logo to be included on the Monument Sign, and the manner in which it is attached to the Monument Sign, shall comply with all Applicable Laws and shall be subject to the reasonable approval of Landlord and any applicable governmental authorities. Landlord reserves the right to withhold consent to any signage that, in the reasonable judgment of Landlord, is not harmonious with the design standards of the Building and Monument Sign. Landlord shall have the right to require that all names or logos on the Monument Sign be of the same size and style. Tenant must obtain Landlord’s written consent to any proposed signage and lettering or logo design prior to its fabrication and installation. The location of Tenant’s logo on the Monument Sign shall be subject to Landlord’s reasonable approval. To obtain Landlord’s consent, Tenant shall submit design drawings to Landlord showing the type and sizes of all lettering; the colors, finishes and types of materials used; and (if applicable and Landlord consents in its reasonable discretion) any provisions for illumination. Although the Monument Sign will be maintained by Landlord, Tenant shall pay its proportionate share of the cost of any maintenance and repair associated with the Monument Sign. Tenant’s signage on the Monument Sign shall be designed, constructed, installed, insured, maintained, repaired and removed from the Monument Sign all at Tenant’s sole risk, cost and expense. Landlord shall be responsible for the maintenance, repair or replacement of Tenant’s signage on the Monument Sign, the cost of which shall be included in Operating Expenses. Landlord may, at any time during the Term (or any extension thereof), upon five (5) business days prior written notice to Tenant, relocate the position of Tenant’s signage on the Monument Sign (provided that if Tenant is the sole tenant on the monument sign, Landlord shall make no such relocation without Tenant’s prior written consent, which consent shall not be unreasonably withheld) without materially impairing its visibility. The cost of such relocation shall be at the cost and expense of Landlord. The rights provided in this Section 23 shall be non-transferable unless otherwise agreed by Landlord in writing in its sole discretion.

  • Sub-Contracting 31.1. The Authority approves the appointment of the sub-contractors specified in Schedule 10 (Approved Sub-contractors) in respect of the obligations specified in that Schedule.

  • Electric If Customer has selected an Electricity Fixed Rate on the Application, Customer’s Price will be based on the Fixed Rate(s) which includes Local and State taxes, Gross Receipts Tax (GRT), PJM Adjustment (defined below) charges and adjustments and Utility applied charges and/or fees related to generation, plus the Administration Charge, which includes, Electricity Balancing Amount and third party utility and billing charges. Customer understands and agrees that included in the Administration Charge is the cost of the Energy Balancing Amount (defined below). Customer understands that in order for RITERATE ENERGY to be able to supply Energy to its existing and prospective customers, RITERATE ENERGY enters into supply arrangements to meet the forecasted consumption of its various groups of customers. These forecasts are based on historical data, load shapes and/or estimates. To the extent that actual pooled consumption of RITERATE ENERGY’s Energy customers varies from supply arrangements and/or Customer’s Utility delivery requirements, RITERATE ENERGY incurs a cost in balancing and settling its supply arrangements with such pooled consumption. To ensure a fixed all-inclusive Rate, RITERATE ENERGY has included in the Administration charge, the Energy Balancing Amount, to balance and settle the variance between pooled consumption and supply arrangements (the “Energy Balancing Amount”). In respect of Electricity, Customer understands that there are certain estimated pass through costs, made up of charges to RITERATE ENERGY by the PJM Interconnection (“PJM”) and/or Customer’s Utility, including but not limited to ancillary service charges, the cost of unaccounted for electricity, capacity charges and any replacement or recharacterization of these charges. In this regard, the “PJM Adjustment”, is included in the Fixed Price Rate. Customer acknowledges and agrees that by entering into this Agreement, Customer will not be eligible to receive any net metering credits and other incentives to which Customer would otherwise be entitled. Further, included in the Rate are the amounts charged or billed to RITERATE ENERGY or Customer by Customer’s Utility, the PUC or any other regulatory or government entity, including any taxes, delivery, regulated transmission, regulated distribution, pipeline, compressor fuel, uplift, congestion, locational marginal pricing, invoice market participant, service, billing, or similar or related changes and any, deposits, interest or late payment fees or other amounts in connection with the supply and delivery of Energy to the Premises (collectively, “Regulatory Charges”). Customer agrees to pay the monthly Administration charge for Energy supply (the “Administration” charge).

Time is Money Join Law Insider Premium to draft better contracts faster.