Location of Meters Sample Clauses

Location of Meters. The metering points to record the kW and kWh exchange between the Plant and the Purchaser's system shall be located as depicted in Schedule 2 - and shall utilise current and voltage transformers. Both the Main Meter and the Back-up Meter shall be installed in a separate room or cabinet and shall only be accessed by the Purchaser and Seller as prescribed in Clause Error! Reference source not found. of this Agreement <Provide specifications of the Tariff and Back up meters and of the Remote Terminal Units>  Energy ChargePayments for Ancillary Services and other Supplimentary Charges if payable by the Seller
AutoNDA by SimpleDocs
Location of Meters. Sale of power from various solar plots in the 250MW Solar Park shall be at 220 kV level of 33/220kV AIS Substation. Energy metering system (main, check and standby meter) will be provided at 220 kV line feeding Solar Power from the Solar Park.
Location of Meters. All meters shall be installed in a location which is readily accessible at all times to BL&P’s personnel.
Location of Meters. The locations for installation of utility meters shall comply with the City’s adopted construction codes.
Location of Meters. All meters shall be so located that they are easily accessible to meter readers and repairmen and protected from freezing.
Location of Meters. The customer shall provide an approved ring type minimum 200 amp meter base with the exception of an overhead feed RV only meter base. The meter base should be installed on the exterior surface of the building on the road or driveway side nearest to the supply line. The meter base must be securely mounted to the structure at a height of 5 to 7 feet above finished grade. All meter base locations must be pre‐approved by the District.
Location of Meters. The metering points to record the kW and kWh exchange between the Plant and the Purchaser's system shall be located as depicted in Schedule 2 - and shall utilise current and voltage transformers. Both the Main Meter and the Back-up Meter shall be installed in a separate room or cabinet and shall only be accessed by the Purchaser and Seller as prescribed in Clause 8 of this Agreement Type Precision Accuracy Type Poly-phase Energy Meters Standard IEC 62052-11 and IEC 62053-22 Current rating 1 A Accuracy class 0.2 Measurement range 20 – 100% of rated current Burden 3.2 VA Rated voltage 16.5/3 V Measure range 90 to 110 % of the rated voltage The Meters shall be capable of constantly recording and storing the power delivered by the Facility over any period of time in kW. Specifications of Current Transformers Standard IEC 61869-1 and IEC 61869-2 Number of phases Single Location Outdoor Highest system voltage 36 kV/145 kV (as applicable) Rated system voltage 33 kV/132 kV (as applicable) Rated frequency 50 Hz Burden 15VA Transformer cores (i) Class 5P20, Ratio: (…) / 1A for over current and earth fault protection.
AutoNDA by SimpleDocs
Location of Meters. The Net Electrical Output for each Unit shall be measured by Seller's electricity metering devices located at the Electricity Metering Points ("UNIT METERS - ELECTRICITY"). The general location of the Electricity Metering Points is shown on Figure AC-1. The Unit Meters - Electricity will be owned and operated in accordance with the Agreement. Metering devices will also be located on Entergy's and TVA's side of the Interconnection Points in the approximate location shown on Figure AC-1 to measure energy delivered by Seller at the Interconnection Points ("UTILITY METERS"). The Utility Meters will be owned and operated by Entergy and TVA.
Location of Meters. All meters shall be installed in a location which is readily accessible at all times to GBPC’s personnel.

Related to Location of Meters

  • Ownership and Location of Metering Equipment The Metering Equipment to be constructed, the capability of the Metering Equipment to be constructed, and the ownership thereof, are identified on the attached Schedule C to this ISA.

  • Location of Equipment The Customer shall not remove the Equipment from the location shown herein as the place of use of the equipment, without prior written approval of the Company. The Customer shall inform the Company by email upon demand of the exact location of the Equipment while it is in the Customer’s possession.

  • Location of Office The Company shall make available to Executive an office and support services at the Company’s headquarters in Dallas/Plano, Texas area. Executive’s main office shall be at such location.

  • Place of Business; Location of Collateral The address set forth in the heading to this Agreement is Borrower's chief executive office. In addition, Borrower has places of business and Collateral is located only at the locations set forth on the Schedule. Borrower will give Silicon at least 30 days prior written notice before opening any additional place of business, changing its chief executive office, or moving any of the Collateral to a location other than Borrower's Address or one of the locations set forth on the Schedule.

  • Location of Real Property The Perfection Certificate lists correctly, in all material respects, as of the Closing Date all Material Real Property owned by the Borrower and the Subsidiary Loan Parties and the addresses thereof. As of the Closing Date, the Borrower and the Subsidiary Loan Parties own in fee all the Real Property set forth as being owned by them in the Perfection Certificate except to the extent set forth therein.

  • Location of Offices The Borrower’s jurisdiction of organization, principal place of business and chief executive office and the office where the Borrower keeps all the Records is located at the address of the Borrower referred to in Section 12.2 hereof (or at such other locations as to which the notice and other requirements specified in Section 5.1(m) shall have been satisfied).

  • Maintenance of Office and Transfer Books by the Depositary Until termination of this Deposit Agreement in accordance with its terms, the Depositary shall maintain in the Borough of Manhattan, The City of New York, facilities for the execution and delivery, registration, registration of transfers, combinations and split-ups and surrender of Receipts in accordance with the provisions of this Deposit Agreement. The Depositary shall keep books for the registration of Receipts and transfers of Receipts which at all reasonable times shall be open for inspection by the Owners, provided that such inspection shall not be for the purpose of communicating with Owners for an object other than the business of the Company, including without limitation a matter related to this Deposit Agreement or the Receipts. The Depositary may close the transfer books after consultation with the Company to the extent practicable, at any time or from time to time, when deemed expedient by it in connection with the performance of its duties hereunder or at the request of the Company, provided that any such closing of the transfer books shall be subject to the provisions of Section 2.06 which limit the suspension of withdrawals of Shares. If any Receipts or the American Depositary Shares evidenced thereby are listed on one or more stock exchanges in the United States, the Depositary shall act as Registrar or, with the written approval of the Company, appoint a Registrar or one or more co-registrars for registry of such Receipts in accordance with any requirements of such exchange or exchanges. The Company shall have the right, upon reasonable request, to inspect the transfer and registration records of the Depositary relating to the Receipts, to take copies thereof and to require the Depositary and any co-registrars to supply copies of such portions of such records as the Company may request.

  • Location of Inventory and Equipment The Inventory and Equipment are not stored with a bailee, warehouseman, or similar party (without Foothill's prior written consent) and are located only at the locations identified on Schedule 6.12 or otherwise permitted by Section 6.12.

  • Location of Equipment and Inventory All Equipment and Inventory are (i) located at the locations indicated on Schedule 4 (ii) in transit to such locations or (iii) in transit to a third party purchaser which will become obligated on a Receivable to the Debtor upon receipt. Except for Equipment and Inventory referred to in clauses (ii) and (iii) of the preceding sentence, the Debtor has exclusive possession and control of the Inventory and Equipment.

  • Licenses for Permanent Installation The contractor must comply with all State mandatory licensing requirements prior to installation. Questions on licensing requirements should be directed to the State Licensing Board. Contractor must furnish and install all furniture and materials in compliance with all applicable codes, whether local, state, or federal; and that all permits or licenses required for installation will be obtained without cost to the State.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!