Preoperational Tests Sample Clauses

Preoperational Tests. (a) Following the successful completion of Construction and Installation Tests of all relevant Equipment and Systems, and after the Unit has achieved Mechanical Completion, Preoperational Tests shall be performed to demonstrate that the Equipment and Systems of the Unit perform in accordance with applicable design criteria so that initial Nuclear Fuel loading, initial criticality, and subsequent power operation can be safely undertaken. Notwithstanding the foregoing sentence, Preoperational Tests may be performed prior to Mechanical Completion of the applicable Unit and prior to completion of all Construction and Installation Tests for such Unit, if the overall Unit configuration supports such Preoperational Test(s) and any applicable ITAAC and the results of such test(s) would be valid. Preoperational Tests at elevated pressure and temperature are referred to as hot functional tests. The general objectives of the Preoperational Test program are the following: • Demonstrate that essential Unit Equipment and Systems, including alarms and indications, meet appropriate criteria based on the design, • Provide Documentation of the performance and condition of the Equipment and Systems, • Provide baseline test and operating data on Equipment and Systems for future use and reference, • Operate Equipment and Systems for a sufficient period to demonstrate performance, • Demonstrate that the Equipment and Systems operate on an integrated basis, and • Perform calibration, balancing and tuning of Equipment and Systems as necessary to insure reliable operation for the specified range of operational conditions. Abstracts for the Preoperational Tests for portions of Systems/Equipment that perform safety-related functions; perform defense-in-depth functions; contain, transport, or isolate radioactive material; and for other applicable Systems/Equipment are specified in Chapter 14 of the Design Control Document.
AutoNDA by SimpleDocs

Related to Preoperational Tests

  • Commissioning preparation of a system or systems to allow hydrocarbons or other process fluids to be safely introduced into the system or systems for processing. In this phase testing will focus on systems, including utilities.

  • Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.

  • Acceptance Testing The MCP must have the capability to report all elements in the Minimum Data Set as set forth in the ODJFS Encounter Data Specifications and must submit a test file in the ODJFS-specified medium in the required formats prior to contracting or prior to an information systems replacement or update. Acceptance testing of encounter data is required as specified in Section 29(a)(v) of this Appendix.

  • Testing Landlord shall have the right to conduct annual tests of the Premises to determine whether any contamination of the Premises or the Project has occurred as a result of Tenant’s use. Tenant shall be required to pay the cost of such annual test of the Premises; provided, however, that if Tenant conducts its own tests of the Premises using third party contractors and test procedures acceptable to Landlord which tests are certified to Landlord, Landlord shall accept such tests in lieu of the annual tests to be paid for by Tenant. In addition, at any time, and from time to time, prior to the expiration or earlier termination of the Term, Landlord shall have the right to conduct appropriate tests of the Premises and the Project to determine if contamination has occurred as a result of Tenant’s use of the Premises. In connection with such testing, upon the request of Landlord, Tenant shall deliver to Landlord or its consultant such non-proprietary information concerning the use of Hazardous Materials in or about the Premises by Tenant or any Tenant Party. If contamination has occurred for which Tenant is liable under this Section 30, Tenant shall pay all costs to conduct such tests. If no such contamination is found, Landlord shall pay the costs of such tests (which shall not constitute an Operating Expense). Landlord shall provide Tenant with a copy of all third party, non-confidential reports and tests of the Premises made by or on behalf of Landlord during the Term without representation or warranty and subject to a confidentiality agreement. Tenant shall, at its sole cost and expense, promptly and satisfactorily remediate any environmental conditions identified by such testing in accordance with all Environmental Requirements. Landlord’s receipt of or satisfaction with any environmental assessment in no way waives any rights which Landlord may have against Tenant.

  • Quality Service Standards Price Services and the Fund may from time to time agree to certain quality service standards, as well as incentives and penalties with respect to Price Services’ Services hereunder.

  • Project Scope This section should contain SOW summary information including: o Project definition and expected duration o Project goals, objectives, o Priorities & expectations o Project approach & responsibilities o Overall coordination and assumptions

  • Quality Service Standards/NAV Errors Price Associates and the Fund may, from time to time, agree to certain quality service standards, with respect to the Services hereunder. In the event Price Associates is the party responsible for causing an error in the computation of the net asset value for a Fund or share class of a Fund (“NAV Error”), the actions that are required to be taken as to such NAV Error shall be made in accordance with the Fund’s Net Asset Value Error Correction Policy and Procedures (“NAV Error Policy”) attached hereto as Schedule II.

  • Stability Testing Patheon may be requested to conduct stability testing on the Products in accordance with the protocols set out in the Specifications for the separate fees and during the time periods set out in Schedule C to a Product Agreement. Patheon will not make any changes to these testing protocols without prior written approval from Client. If a confirmed stability test failure occurs, Patheon will notify Client within one Business Day, after which Patheon and Client will jointly determine the proceedings and methods to be undertaken to investigate the cause of the failure, including which party will bear the cost of the investigation. Patheon will not be liable for these costs unless it has failed to perform the Manufacturing Services in accordance with the Specifications, cGMPs, and Applicable Laws. Patheon will give Client ail stability test data and results at Client’s request.

  • Tests Based on the AUPs, the Asset Representations Reviewer shall review the Required Documents to determine whether, for each Reviewable Receivable, (a) there was evidence that the applicable Test for such Reviewable Receivable was satisfied, (b) there was evidence that the applicable Test for such Reviewable Receivable was not satisfied or (c) the Test could not be completed as a result of missing or insufficient Required Documents for a Reviewable Receivable. Each Test shall be performed individually. The Asset Representations Reviewer may, at its sole discretion, review additional information that is not required for the Asset Representations Review as defined by the AUPs, but it is not required to do so.

  • Repairs; Maintenance and Compliance Borrower shall at all times maintain, preserve and protect all franchises and trade names, and Borrower shall cause the Property to be maintained in a good and safe condition and repair and shall not remove, demolish or alter the Improvements or Equipment (except for alterations performed in accordance with Section 5.4.2 below and normal replacement of Equipment with Equipment of equivalent value and functionality). Borrower shall promptly comply with all Legal Requirements and immediately cure properly any violation of a Legal Requirement. Borrower shall notify Lender in writing within two (2) Business Days after Borrower first receives notice of any such non-compliance. Borrower shall promptly repair, replace or rebuild any part of the Property that becomes damaged, worn or dilapidated and shall complete and pay for any Improvements at any time in the process of construction or repair.