Ventilation / Air Conditioning. Areas accessible to the public / drivers shall be equipped with sufficient air conditioning and ventilation. For manual/semi automate systems, where human presence in the storage areas is envisaged, adequate ventilation of vehicle emissions shall be provided. Basement shall have mechanical ventilation. The system shall be designed to provide positive and uniform supply of fresh air in the parking and its exhaust through ducts / fans. The ventilation system shall be designed to achieve minimum 15 air changes / hour in the parking / hours of exhaust in case of fire. The GI sheets for the sheet metal ductwork shall conform to IS- 227 and the ductwork shall be fabricated and executed strictly as per the requirements of IS-655. The Storage area of the System in which no drivers enter but only maintenance crews, may be unconditioned space, although ventilation of outside air shall be provided. No Ventilation of vehicle emissions is required inside the storage area. Depending on the design of the Entry and Exit Areas, ventilation of emissions shall be required in that area.
AutoNDA by SimpleDocs
Ventilation / Air Conditioning. Services to be performed as part of scheduled preventative maintenance for ventilation/air conditioners is to include:  Clean and inspect the filter area of the evaporator unit.  Change filters.  Wipe-out drip pan. Make sure condenser drains freely by running water down it. If it does not drain right away, clean out drain line. There shall be no standing water in the drip pan.  Verify that air intakes are not blocked. Clean any visible debris.  Ensure winter / summer functions are set and operating correctly using remote control.  Inspect system for refrigerant leaks. Report to FAC if leak exists.  Inspect fan belts (if equipped). Replace worn belts as needed.  Return unit to service.  Check indoor unit for: excess noise, proper cooling (discharge temperature must be able to run at lowest, normally 17 Celsius), all cycles should operate (e.g., fan only, dehumidification, and cooling).  Record all the NEPA numbers in the log book.  List all materials used in the log book.  Clean-up work space.
Ventilation / Air Conditioning. Areas accessible to the public / drivers shall be equipped with sufficient air conditioning and ventilation. The system shall be designed to provide positive and uniform supply of fresh air in the parking and its exhaust through ducts/ fans. The ventilation system shall be designed to achieve minimum 15 air changes /hour in the parking areas during the normal operation and should achieve minimum 30 air changes/hour of exhaust in case of fire. Depending on the design of the Entry and Exit Areas, ventilation of emissions shall be required in that area.

Related to Ventilation / Air Conditioning

  • Ventilation Where noxious or poisonous gases may accumulate, the City shall provide proper protection and ventilation. Proper lighting and ventilation shall be provided for all enclosed working spaces. All work in enclosed and confined spaces shall be performed in accordance with applicable Federal, State and local regulations. Spray painting shall be done only by qualified painters.

  • Heating The Hirer shall ensure that no unauthorised heating appliances shall be used on the premises when open to the public without the consent of the management committee. Portable Liquefied Propane Gas (LPG) heating appliances shall not be used.

  • HVAC A. Heating, ventilating and air conditioning equipment will be provided with sufficient capacity to accommodate a maximum population density of one (1) person per one hundred fifty (150) square feet of useable floor area served, and a combined lighting and standard electrical load of 3.0 xxxxx per square foot of useable floor area. In the event Tenant introduces into the Premises personnel or equipment which overloads the system’s ability to adequately perform its proper functions, Landlord shall so notify Tenant in writing and supplementary system(s) may be required and installed by Landlord at Tenant’s expense, if within fifteen (15) days Tenant has not modified its use so as not to cause such overload. Operating criteria of the basic system shall not be less than the following:

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Elevators Landlord shall provide passenger elevator service during normal business hours to Tenant in common with Landlord and all other tenants. Landlord shall provide limited passenger service at other times, except in case of an emergency.

  • Plumbing fixtures and appliances shall be used only for the purposes for which designed, and no sweepings, rubbish, rags or other unsuitable material shall be thrown or deposited therein. Damage resulting to any such fixtures or appliances from misuse by a tenant or its agents, employees or invitees, shall be paid by such tenant.

Time is Money Join Law Insider Premium to draft better contracts faster.