Capacity scheduling Sample Clauses

Capacity scheduling. 5.1 ZEEKR shall submit the rolling scheduled capacity plan for "1+3" years starting from the next year to Chengdu Factory in accordance with the scheduled capacity plan submission rules formulated by Chengdu Factory every year. Chengdu Factory shall make best efforts to meet the capacity requirements proposed by ZXXXX. It is a locked capacity for the first year and scheduled capacity for the next three years.
AutoNDA by SimpleDocs
Capacity scheduling. 5.1 Party A shall update the annual demand of "1+3" to Party B on a rolling basis before September 30 of each year, and output the final version before November 15 of each year, where the capacity for the first year ("1") shall be the locked capacity, and the capacity for the following three years ("3") shall be the scheduled capacity. "
Capacity scheduling. Each Party shall designate an authorized representative to effect the scheduling of the supply of Electricity and Steam pursuant to this Agreement. On or before 7:00 a.m. PPT on any Business Day, CREH shall give the Company written notice, in a format mutually agreed by the Company and CREH, of Electricity to be supplied under this Agreement for each hour of the following day (and, at CREH’s discretion, for any additional days thereafter), subject to limitations in availability due to Force Majeure, forced outage or other malfunction, or planned outage as reflected in the Planned Power Outage Schedule.

Related to Capacity scheduling

  • Scheduling (a) Lessee will provide Lessor with requests for flight time and proposed flight schedules as far in advance of any given flight as possible. Lessee or the designated authorized representative(s) of Lessee shall submit scheduling requests under this Agreement to the designated authorized representative(s) of Lessor. Requests for flight time shall be in such form (whether oral or written) mutually convenient to, and agreed upon by, the parties. In addition to proposed schedules and flight times, Lessee shall upon request provide Lessor with the following information for each proposed flight prior to scheduled departure: (i) proposed departure point; (ii) destination; (iii) date and time of flight; (iv) the number of anticipated passengers; (v) the nature and extent of luggage to be carried; (vi) the date and time of a return flight, if any; and (vii) any other pertinent information concerning the proposed flight that Lessor or the flight crew may request.

  • Commissioning preparation of a system or systems to allow hydrocarbons or other process fluids to be safely introduced into the system or systems for processing. In this phase testing will focus on systems, including utilities.

  • Delivery Schedule The scheduled months of delivery of the Aircraft are listed in the attached Table 1. Exhibit B describes certain responsibilities for both Customer and Boeing in order to accomplish the delivery of the Aircraft.

  • Emergency Generator Tenant shall have the right to tie into and use the emergency generator to be installed by Landlord as part of the Base Building Work for use by tenants of the Unit (the “Unit Generator”). Tenant shall be responsible, at its sole cost and expense, for installing, maintaining, repairing and replacing its connection between the Premises and the Unit Generator, and all associated cabling. Tenant shall be permitted to use up to an average of three (3) xxxxx per square foot of usable area in the Premises from the Unit Generator, and at no time shall Tenant exceed that use limitation with respect to the Unit Generator. Except to the extent that Tenant ties into the Unit Generator as part of the Initial Tenant Work in accordance with the provisions of the Work Letter, installation of such tie-in and any related cabling, conduit and appurtenances will be governed by the applicable provisions of this Lease relating to Tenant Work. Tenant will submit to Landlord at least thirty (30) days prior to the proposed installation date Tenant’s proposed plans and specifications relating to the tie-in to the Unit Generator and all associated lines. Tenant may not commence any work to tie into the Unit Generator until it has received Landlord’s prior written approval (not to be unreasonably withheld, delayed or conditioned) of such plans and specifications. Tenant, at its sole cost and expense, shall comply with all applicable Legal Requirements and Title Matters and Landlord’s reasonable directives relating to the installation, operation, maintenance and repair of such tie-in, including (i) obtaining and maintaining (or causing to be obtained and maintained) and complying with the provisions of all applicable permits relating to the tie into and use of the Unit Generator. Tenant may not use the Unit Generator for any purpose other than solely in connection with Tenant’s occupancy of the Premises for the Permitted Use and in accordance with any applicable permit(s) pertaining to the Unit Generator. Except for permitted subtenants and assignees. Tenant may not use the Unit Generator to serve other occupant(s) of the Development.

  • Designated Configuration; Trained Personnel State Street and the Fund shall be responsible for supplying, installing and maintaining the Designated Configuration at the Designated Locations. State Street and the Fund agree that each will engage or retain the services of trained personnel to enable both parties to perform their respective obligations under this Addendum. State Street agrees to use commercially reasonable efforts to maintain the System so that it remains serviceable, provided, however, that State Street does not guarantee or assure uninterrupted remote access use of the System.

  • Project Schedule Contractor shall perform the Work in accordance with the Project Schedule.

  • Change Orders Tenant shall have the right, in accordance herewith, to submit for Landlord's approval change proposals subsequent to the completion of the Approved Tenant Improvement Construction Documents (each, a "Tenant Improvement Work Change Proposal"). Landlord agrees to respond to any such Tenant Improvement Work Change Proposal within such time as is reasonably necessary, but no more than five (5) business days, after the submission thereof by Tenant (unless Landlord has previously advised Tenant that a longer time period is reasonably necessary due to the nature and scope of the Tenant Improvement Work Change Proposal, together with Landlord's good faith estimate as to the amount of additional time that will be necessary, or the fact that the information provided by Tenant in the Tenant Improvement Work Change Proposal is insufficient for the purposes of enabling Landlord to make the determination set forth herein), advising Tenant of any items which Landlord in good faith reasonably believes are inconsistent with the design, cost and construction schedule for the Base Building Work, as well as specifying (subject to the terms of Section 5.2 below) whether any alterations, additions or improvements shown in the Tenant Improvement Work Change Proposal must be removed by Tenant upon the expiration or earlier termination of the Term ("Landlord's Tenant Improvement Work Change Order Response") (it being understood and agreed that Landlord's failure to respond within said five (5) business day period shall be deemed to constitute Landlord's approval of the Tenant Improvement Work Change Proposal and determination that none of the items shown thereon are to be removed by Tenant at the expiration or earlier termination of the Term). Tenant shall have the right to then proceed with or withdraw such Tenant Improvement Work Change Proposal within five (5) business days after receipt of Landlord's Tenant Improvement Work Change Order Response. If Tenant fails to respond to Landlord's Tenant Improvement Work Change Order Response within such five (5) business day period, such Tenant Improvement Work Change Proposal shall be deemed withdrawn. If Tenant proceeds with such Tenant Improvement Work Change Proposal, then such Tenant Improvement Work Change Proposal shall be deemed to be a part of the Approved Tenant Improvement Construction Documents for the purposes of this Article III.

  • Work Schedule Within ten (10) days after the execution of this Lease, Landlord will deliver to Tenant, for Tenant's review and approval, a schedule ("Work Schedule") which will set forth the timetable for the planning and completion of the installation of the Tenant Improvements and the Commencement Date of the Lease. The Work Schedule will set forth each of the various items of work to be done or approval to be given by Landlord and Tenant in connection with the completion of the Tenant Improvements. The Work Schedule will be submitted to Tenant for its approval, which approval Tenant agrees not to unreasonably withhold, and, once approved by both Landlord and Tenant, the Work Schedule will become the basis for completing the Tenant Improvements. All plans and drawings required by this Work Letter Agreement and all work performed pursuant thereto are to be prepared and performed in accordance with the Work Schedule. Landlord may, from time to time during construction of the Tenant Improvements, modify the Work Schedule as Landlord reasonably deems appropriate. If Tenant fails to approve the Work Schedule, as it may be modified after discussions between Landlord and Tenant within five (5) business days after the date the Work Schedule is first received by Tenant, the Work Schedule shall be deemed to be approved by Tenant as submitted or Landlord may, at its option, terminate the Lease upon written notice to Tenant.

  • Review Systems; Personnel It will maintain business process management and/or other systems necessary to ensure that it can perform each Test and, on execution of this Agreement, will load each Test into these systems. The Asset Representations Reviewer will ensure that these systems allow for each Review Receivable and the related Review Materials to be individually tracked and stored as contemplated by this Agreement. The Asset Representations Reviewer will maintain adequate staff that is properly trained to conduct Reviews as required by this Agreement.

  • Technical Specifications Each Bloom System is an integrated system comprised of a fuel cell stack assembly and associated balance of plant components that converts a fuel into electricity using electrochemical means that (i) has a Nameplate Capacity of at least 0.5 kilowatts of electricity using an electrochemical process and (ii) has an electricity-only generation efficiency greater than thirty percent (30%).

Time is Money Join Law Insider Premium to draft better contracts faster.