CORROSION SURVEY AND STRAY CURRENT REPORT Sample Clauses

CORROSION SURVEY AND STRAY CURRENT REPORT. It is not anticipated that corrosion investigations beyond the soil corrosivity testing to be performed as part of geotechnical investigation will be required. However, the Consultant shall coordinate with the Water Operations Corrosion Control Group at the direction of the City’s Project Manager and incorporate corrosion recommendations into the project design.
AutoNDA by SimpleDocs
CORROSION SURVEY AND STRAY CURRENT REPORT. ‌ 1. Design an impressed current cathodic protection (ICCP) system for the main pipeline consisting of multiple deep anode groundbeds and air cooled, manually controlled, rectifiers installed in the standard City of San Diego free standing enclosure. All rectifier/enclosure assemblies shall have GPS synchronizable interruption capability compatible with the existing City of San Diego/American Innovations MicroMax GPS 80 controllers. a. Deep anode groundbeds are the most desirable type of CP groundbed by the City Public Utilities Department Water System Operations Division. The CONSULTANT shall perform either seismic refraction or ReMi geophysical surveys to a minimum depth of 150 feet to identify areas along the pipeline alignment that may contain shallow bedrock and identify suitable locations for drilling the 150 foot deep anode groundbeds. Areas of shallow bedrock should be avoided for the installation of rectifiers and anode groundbeds whenever possible. b. The CP system shall be designed for a steel pipeline with a dielectric tape coating and cement-mortar overcoat. The tape coating shall be in accordance with AWWA C214 and the cement mortar overcoat shall be in accordance with AWWA C205. The pipeline shall have fully circumferentially welded joints. Non welded joints shall have joint bond wires installed. The pipeline shall have a cement-mortar lining per AWWA C205. c. The CP system shall be designed to satisfy the -0.850 Volt polarized potential criterion in accordance with XXXX SP0169 at all points along its length. d. Prepare and submit CP system design calculations reviewed and certified by a XXXX XX-4 Cathodic Protection Specialist and a CP system Basis of Design Report which outlines the design approach and presents the results of any geophysical testing performed. 2. The main pipeline shall be electrically segmented along its length using in line electrical isolation devices (e.g. insulated pipe flanges) in order to allow for the use of smaller, more manageable, and operationally flexible CP systems. The use of one continuous CP system design for the entire pipeline will not be allowed. 3. The main pipeline shall be electrically isolated from intermediate pumping stations, connections to existing pipelines and facilities, electrically grounded equipment, and reinforced concrete structures. Design independent galvanic anode or impressed current CP systems for all suction and discharge yard piping associated with the intermediate pumping station...

Related to CORROSION SURVEY AND STRAY CURRENT REPORT

  • Adverse Report The Employer shall notify an employee in writing of any expression of dissatisfaction concerning his work within ten (10) working days of the event of the complaint, with a copy to the Union. This notice shall include particulars of the work performance which led to such dissatisfaction. If this procedure is not followed, such expression of dissatisfaction shall not become a part of his work record for use against him at any time. This Article shall be applicable to any complaint or accusation which may be detrimental to an employee's advancement or standing with the Employer, whether or not it relates to his work. The employee's reply to such complaint, accusation or expression of dissatisfaction shall become part of his record. The record of an employee shall not be used against him at any time after twelve (12) months following the serving of a suspension or disciplinary action, including letters of reprimand or any adverse reports.

  • How Do I Get More Information? This Notice summarizes the Action, the terms of the Settlements, and your rights and options in connection with the Settlements. More details are in the Settlement Agreements, which are available for your review at xxx.XxxxxxxxxXxxXxxxxxxxxXxxxxxxxxx.xxx. The Settlement Website also has the Second Amended Complaint and other documents relating to the Settlements. You may also call toll-free 0-000-000-0000 or write the Claims Administrator at: Financial Aid Antitrust Settlements, c/o Claims Administrator, 0000 Xxxx Xxxxxx, Xxxxx 0000, Xxxxxxxxxxxx, XX 00000. To: Settlement Class Member Email Address From: Claims Administrator Subject: Notice of Proposed Class Action Settlement – Xxxxx, et al. x. Xxxxx University, et al. Please visit xxx.XxxxxxxxxXxxXxxxxxxxxXxxxxxxxxx.xxx for more information. • The Court has preliminarily approved proposed settlements (“Settlements”) with the following ten schools: Brown University, the University of Chicago, the Trustees of Columbia University in the City of New York, Trustees of Dartmouth College, Duke University, Emory University, Northwestern University, Xxxxxxx Xxxxx Xxxx University, Vanderbilt University, and Yale University (collectively the “Settling Universities”). • The Court has also preliminarily approved a class of students who attended one or more of the Settling Universities during certain time periods. This is referred to as the “Settlement Class,” which is defined in more detail below.

  • New Hampshire Specific Data Security Requirements The Provider agrees to the following privacy and security standards from “the Minimum Standards for Privacy and Security of Student and Employee Data” from the New Hampshire Department of Education. Specifically, the Provider agrees to: (1) Limit system access to the types of transactions and functions that authorized users, such as students, parents, and LEA are permitted to execute; (2) Limit unsuccessful logon attempts; (3) Employ cryptographic mechanisms to protect the confidentiality of remote access sessions; (4) Authorize wireless access prior to allowing such connections; (5) Create and retain system audit logs and records to the extent needed to enable the monitoring, analysis, investigation, and reporting of unlawful or unauthorized system activity; (6) Ensure that the actions of individual system users can be uniquely traced to those users so they can be held accountable for their actions; (7) Establish and maintain baseline configurations and inventories of organizational systems (including hardware, software, firmware, and documentation) throughout the respective system development life cycles; (8) Restrict, disable, or prevent the use of nonessential programs, functions, ports, protocols, and services; (9) Enforce a minimum password complexity and change of characters when new passwords are created; (10) Perform maintenance on organizational systems; (11) Provide controls on the tools, techniques, mechanisms, and personnel used to conduct system maintenance; (12) Ensure equipment removed for off-site maintenance is sanitized of any Student Data in accordance with NIST SP 800-88 Revision 1; (13) Protect (i.e., physically control and securely store) system media containing Student Data, both paper and digital; (14) Sanitize or destroy system media containing Student Data in accordance with NIST SP 800-88 Revision 1 before disposal or release for reuse; (15) Control access to media containing Student Data and maintain accountability for media during transport outside of controlled areas; (16) Periodically assess the security controls in organizational systems to determine if the controls are effective in their application and develop and implement plans of action designed to correct deficiencies and reduce or eliminate vulnerabilities in organizational systems; (17) Monitor, control, and protect communications (i.e., information transmitted or received by organizational systems) at the external boundaries and key internal boundaries of organizational systems; (18) Deny network communications traffic by default and allow network communications traffic by exception (i.e., deny all, permit by exception); (19) Protect the confidentiality of Student Data at rest; (20) Identify, report, and correct system flaws in a timely manner; (21) Provide protection from malicious code (i.e. Antivirus and Antimalware) at designated locations within organizational systems; (22) Monitor system security alerts and advisories and take action in response; and (23) Update malicious code protection mechanisms when new releases are available.

  • Title Report If no Additional Mortgage Policy is required with respect to such Additional Mortgaged Property, a title report issued by the Title Company with respect thereto, dated not more than 30 days prior to the date such Additional Mortgage is to be recorded and satisfactory in form and substance to Administrative Agent;

  • Title Policy and Survey A. TITLE POLICY: Seller shall furnish to Buyer at Seller’s Buyer’s expense an owner policy of title insurance (Title Policy) issued by (Title Company) in the amount of the Sales Price, dated at or after closing, insuring Buyer against loss under the provisions of the Title Policy, subject to the promulgated exclusions (including existing building and zoning ordinances) and the following exceptions: (1) Restrictive covenants common to the platted subdivision in which the Property is located. (2) The standard printed exception for standby fees, taxes and assessments. (3) Liens created as part of the financing described in Paragraph 3. (4) Utility easements created by the dedication deed or plat of the subdivision in which the Property is located. (5) Reservations or exceptions otherwise permitted by this contract or as may be approved by Xxxxx in writing. (6) The standard printed exception as to marital rights. (7) The standard printed exception as to waters, tidelands, beaches, streams, and related matters. (8) The standard printed exception as to discrepancies, conflicts, shortages in area or boundary lines, encroachments or protrusions, or overlapping improvements: (i) will not be amended or deleted from the title policy; or (ii) will be amended to read, "shortages in area" at the expense of Buyer Seller. (9) The exception or exclusion regarding minerals approved by the Texas Department of Insurance.

  • Adverse Weather Shall be only weather that satisfies all of the following conditions: (1) unusually severe precipitation, sleet, snow, hail, or extreme temperature or air conditions in excess of the norm for the location and time of year it occurred based on the closest weather station data averaged over the past five years, (2) that is unanticipated and would cause unsafe work conditions and/or is unsuitable for scheduled work that should not be performed during inclement weather (i.e., exterior finishes), and (3) at the Project.

  • Escrow Format Specification Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Material Safety Data Sheet Seller shall provide to Buyer with each delivery any Material Safety Data Sheet applicable to the work in conformance with and containing such information as required by the Occupational Safety and Health Act of 1970 and regulations promulgated thereunder or its State approved counterpart.

  • Title and Survey Review The condition of the title to the Properties. Prior to the Effective Date, Seller has provided to Buyer an ALTA title report or commitment for title insurance (individually, a “Title Commitment” and collectively, the “Title Commitments”) prepared by First American Title Insurance Company (the “Title Company”) with respect to each Real Property. Buyer may request from the Title Company an updated Title Commitment, together with copies of all documents referred to therein, for any or all of the Properties. Prior to the Effective Date, Seller has provided to Buyer a copy of an existing survey of each Property, and Buyer may, at Buyer’s sole cost and expense, obtain an update of each survey (the “Surveys”). It shall be a condition to Closing that the Title Company shall be committed to issue to Buyer an ALTA extended coverage Owner’s Policy of Title Insurance for each Property, in an amount equal to the Allocated Purchase Price and insuring title to each Property is vested in Buyer, subject only to the “Permitted Exceptions” (as hereinafter defined) and including only the “Endorsements” (as hereinafter defined) (individually and collectively, the “Title Policy”). The following matters shall be deemed “Permitted Exceptions”: all matters disclosed by the Title Commitments other than (A) those matters which the Title Company has removed from the Title Commitment by written supplement and (B) those “Mandatory Cure Items” (as hereinafter defined). “Mandatory Cure Items” shall mean (1) those matters which Seller has agreed in writing to cause to be removed at or before Closing in accordance with, and subject to, Paragraph 3(c), (2) any mortgages, deeds of trust or other similar encumbrance evidencing outstanding indebtedness voluntarily created by Seller which can be satisfied by the payment of an ascertainable amount of money, and (3) any mechanic’s, materialman’s or broker’s liens filed against a Property as a result of Seller’s acts or omissions (e.g., failure to pay) which can be satisfied by the payment of an ascertainable amount of money. The “Endorsements” shall include only those endorsements which, prior to the expiration of the Due Diligence Period, the Title Company has agreed in writing to include in the applicable Title Policy or Seller has agreed in writing to cause to be included in such Title Policy;

  • Title Information (a) On or before the delivery to the Administrative Agent and the Lenders of each Reserve Report required by Section 8.12, the Borrower will deliver title information in form and substance acceptable to the Administrative Agent covering enough of the Oil and Gas Properties evaluated by such Reserve Report that were not included in the immediately preceding Reserve Report, so that the Administrative Agent shall have received together with title information previously delivered to the Administrative Agent, satisfactory title information on at least 80% of the total value of the Oil and Gas Properties evaluated by such Reserve Report. (b) If the Borrower has provided title information for additional Properties under Section 8.13(a), the Borrower shall, within 60 days of notice from the Administrative Agent that title defects or exceptions exist with respect to such additional Properties, either (i) cure any such title defects or exceptions (including defects or exceptions as to priority) which are not permitted by Section 9.03 raised by such information, (ii) substitute acceptable Mortgaged Properties with no title defects or exceptions except for Excepted Liens (other than Excepted Liens described in clauses (e), (g) and (h) of such definition) having an equivalent value or (iii) deliver title information in form and substance acceptable to the Administrative Agent so that the Administrative Agent shall have received, together with title information previously delivered to the Administrative Agent, satisfactory title information on at least 80% of the value of the Oil and Gas Properties evaluated by such Reserve Report. (c) If the Borrower is unable to cure any title defect requested by the Administrative Agent or the Lenders to be cured within the 60-day period or the Borrower does not comply with the requirements to provide acceptable title information covering 80% of the value of the Oil and Gas Properties evaluated in the most recent Reserve Report, such default shall not be a Default, but instead the Administrative Agent and/or the Majority Lenders shall have the right to exercise the following remedy in their sole discretion from time to time, and any failure to so exercise this remedy at any time shall not be a waiver as to future exercise of the remedy by the Administrative Agent or the Lenders. To the extent that the Administrative Agent or the Majority Lenders are not satisfied with title to any Mortgaged Property after the 60-day period has elapsed, such unacceptable Mortgaged Property shall not count towards the 80% requirement, and the Administrative Agent may send a notice to the Borrower and the Lenders that the then outstanding Borrowing Base shall be reduced by an amount as determined by the Majority Lenders to cause the Borrower to be in compliance with the requirement to provide acceptable title information on 80% of the value of the Oil and Gas Properties. This new Borrowing Base shall become effective immediately after receipt of such notice.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!