Electrical design requirements Sample Clauses

Electrical design requirements. The existing transformer specification is as follows: Power Rating Secondary Primary 70kVP 1370mAM 380V 252A Table 7: TR set rating The existing transformers are rated to supply 270.4µA/m2 to the field. It is the Contractor’s responsibility to design and provide a single adequately sized HFPS unit per field for the application at Duvha Power Station that has as a minimum the following secondary output rating: kV mA 80 1900 Table 8: Minimum HFPS rating The minimum method of cooling employed is Oil Natural Air Natural (ONAN) taking site altitude and temperature rise into consideration. Based on the applicable ambient and environmental conditions ONWF (Oil Natural Water Forced) cooling is not preferred. High Frequency is defined as operating at 20 kHz or above on the secondary side. The Contractor supplies a three-phase HFPS that shall result in the ESP efficiency improvement and yield an overall optimal output. The scope includes but is not limited to replacing the first 3 fields’ conventional Transformer Rectifier with the HFPSs on both casings per unit. It is not the intent of this project to change the existing electrical power reticulation including the power supply configuration as much as possible. • The expectation is that the 1250kVA Precipitator Transformer must be adequate for the installation of HFPS on the first 3 fields. • The Contractor notifies the Employer by means of a power reticulation study whether the 1250kVA Precipitator Transformer is adequate to accommodate HFPS on the remaining fields to allow the Employer to make the necessary arrangements to accommodate HFPS’s at a later stage on the remaining fields. • The Contractor verifies the phase balancing on the remaining fields that are fitted with Rectifier Transformers after installation of the HFPS on the first 3 fields. The new HFPSs are adequately designed to operate optimally under the following abnormal conditions. • The new HFPSs must be adequately designed to operate optimally under the following abnormal conditions: o Continuous primary voltage overloading at 110% and undervoltage of 90% of the transformer design o The HFTs should comply to the volt dip immunity criteria as per Eskom standard 240- 56361454 for primary under Voltage disturbances: ▪ A three phase voltage drop to zero for 0.2 s ▪ A voltage drop to 75% of nominal voltage for 1 s ▪ A voltage drop to 85% of nominal voltage for 60 s. ▪ The Contractor will be responsible for demonstrating under test conditions that this ...
AutoNDA by SimpleDocs
Electrical design requirements. The requirements for the design of the electrical distribution system and the morality lighting shall be submitted to the Town of Ajax for review and approval prior to the commencement of the design.

Related to Electrical design requirements

  • Design Requirements 9.2.1. Metal liner The compressive stress in the liner at zero pressure and 15 °C shall not cause the liner to buckle or crease.

  • Installation requirements 7.8 We (if we install the System) or our contractor (if we procure a contractor to install the System) must:

  • Electrical Safety Only UL approved items are permitted in Housing & Residence Life. Extension and multi-use cords must be heavy duty, single plug, and be UL approved. Altering or adapting electrical outlets and equipment and overloading circuits jeopardize safety and thus are not permitted.

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • Equipment and Software Requirements In order to view and retain electronic communications that we make available to you, you must have: • A PC or other device with an Internet browser that has “cookies” enabled and supports 128 bit encryption • An Internet connection • An email address • A PDF viewer (such as Adobe Reader) • A printer or computer with sufficient electronic storage space All communications shall be delivered to the last address we have on file for you. These notices will be sent through electronic delivery (email) and will be considered delivered the same day as sent. If you have opted out of electronic delivery, communications sent to you through the United States Postal Service are considered delivered 5 business days after the postmark date. It is your responsibility to notify the Custodian of any email address change or residential address change. We will not be held liable for any losses or damages if you have not provided Custodian with the most current address information. The electronically signed copy of this document should be considered equivalent to a printed hard copy form. It is considered a true and complete record of the document, admissible in arbitration and/or administrative hearings or proceedings. Your electronic signature on the Application and other electronic forms such as the Investment Direction are considered valid and the same as if the paper form or Application were signed.

  • Closet/Urinal Requirements 6.1 Employees Closets Urinals 1-5 1 Nil 6-10 1 1 11-20 2 2 21-35 3 4 36-50 4 6 51-75 5 7 76-100 6 8

  • Construction Requirements a) All Life and Safety and applicable Building Codes will be strictly enforced (i.e., tempered glass, fire dampers, exit signs, smoke detectors, alarms, etc.). Prior coordination with the Building Manager is required.

  • Technical and Interconnection Requirements 2.1 Consumer agrees that his Rooftop Solar PV System and Net Metering System will conform to the standards and requirements specified in the Policy, Regulations and Supply Code as amended from time to time.

  • Food Service Waste Reduction Requirements Contractor shall comply with the Food Service Waste Reduction Ordinance, as set forth in San Francisco Environment Code Chapter 16, including but not limited to the remedies for noncompliance provided therein.

  • Technical Requirements 2.7.4.1 The NID shall provide an accessible point of interconnection and shall maintain a connection to ground.