Fence Corner, Line Brace, Cattle Guard and Gate Sample Clauses

Fence Corner, Line Brace, Cattle Guard and Gate. (i) The parties agree that Tenant will employ a professional fencing company, agreeable to both parties, to install all such braces, stretch all such fences, and install all cattle guards, but only to the extent Tenant installs any such braces, fences or cattle guards on the Property. If the parties cannot agree on a fencing or cattle guard contractor then Tenant shall solicit offers from three contractors and Tenant shall have the right to choose which of these companies to employ. Owner may request that Tenant utilize a different fencing company; provided, however, Owner shall be responsible for any additional costs above the cost of the company chosen by Txxxxx. At Owner’s option, any such additional costs may be deducted from payments due to Owner from Tenant under this Agreement. (ii) To the extent applicable to the Tenant’s Improvements, Tenant shall not cut nor create any opening in any present or future fence or fences without first adequately bracing by installing a permanent brace during construction and as appropriate a fence corner, line brace, cattle guard, and/or gate thereafter which meets the standards herein. All openings in fences shall be H braced with dead-man bracing as follows: All metal pipe shall be not less than 4” in diameter, 1/4” thick walls, 10’ in length, 5’ being in the ground, cemented and tamped top to bottom, 5’ above the ground, cross-braced with two 10’ long 2 7/8” pipes for the H brace and one 2 7/8” pipe from the H diagonally to kicker brace, all pipe welded solidly with complete welds to posts. All pipe to be wire brushed, coated with OSPHO rust inhibitor, and one coat of aluminum paint. All concrete will be allowed to set for a minimum of 36 hours before attaching wire to the posts. All pipe openings shall be capped with metal caps. Cattle guards shall be attached to the H brace with five feet high, 4 gauge, galvanized welded wire with 4” x 4” openings. At each point where Tenant installs a cattle guard, the same shall be constructed by Tenant as a raised cattle guard not less than 9’ x 16’ as follows: The top of the cattle guard shall be 3 feet above the ground level after caliche is placed under the cattle guard. Each cattle guard shall rest on concrete supports which are adequate for heavy truck traffic. All such cattle guards shall meet Owner specifications. Tenant shall maintain all cattle guards it installs in good condition with fences properly attached so as to prevent livestock from passing between the cattl...
AutoNDA by SimpleDocs

Related to Fence Corner, Line Brace, Cattle Guard and Gate

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Television Equipment Recycling Program If this Contract is for the purchase or lease of covered television equipment, then Contractor certifies that it is compliance with Subchapter Z, Chapter 361 of the Texas Health and Safety Code related to the Television Equipment Recycling Program.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • Trunk Group Architecture and Traffic Routing 5.2.1 The Parties shall jointly establish Access Toll Connecting Trunks between CLEC and CBT by which they will jointly provide Tandem-transported Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic from and to CLEC's Customers. 5.2.2 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access and non-translated Toll Free traffic (e.g., 800/888) to allow CLEC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier that is connected to the CBT access Tandem. 5.2.3 The Access Toll Connecting Trunks shall be one-way or two-way trunks, as mutually agreed, connecting an End Office Switch that CLEC utilizes to provide Telephone Exchange Service and Switched Exchange Access Service in the given LATA to an access Tandem Switch CBT utilizes to provide Exchange Access in the LATA.

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins. (2) Maintain waterbars, drainage dips, and other water diversion measures. (3) During active use, patrol and maintain functional drainage. (4) Repair damaged culvert ends.

  • Wire Unbundled DS1 Digital Loop This is a designed 4-wire Loop that is provisioned according to industry standards for DS1 or Primary Rate ISDN services and will come standard with a test point, OC, and a DLR. A DS1 Loop may be provisioned over a variety of loop transmission technologies including copper, HDSL-based technology or fiber optic transport systems. It will include a 4-Wire DS1 Network Interface at the End User’s location.

  • TOOL STORAGE 1. A company shall provide on all construction jobs in towns and cities, and elsewhere where reasonably necessary and practicable (or if requested buy the employee), a suitable and secure waterproof lock-up solely for the purpose of storing employees’ tools, and on multi-storey and major projects the company shall provide, where possible, a suitable lock-up for employees’ tools within a reasonable distance of the work area of large groups of employees. 2. Where an employee is absent from work because of illness or accident and has advised the company in accordance with Clause 33 – Personal Leave of the award, the company shall ensure that the employee’s tools are securely stored during his/her absence.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • PREVAILING WAGE RATES - PUBLIC WORKS AND BUILDING SERVICES CONTRACTS If any portion of work being Bid is subject to the prevailing wage rate provisions of the Labor Law, the following shall apply:

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!