We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.

For more information visit our privacy policy.

Inspection; Corrections; Additional Work Sample Clauses

Inspection; Corrections; Additional Work. For the period commencing at least 30 Business Days prior to the Termination Date and continuing until the date on which the Aircraft is returned to Lessor in the condition required by this Lease, Lessee will provide for the review by Lessor and/or its representative all of the Aircraft Documents described in Schedule 1A. Immediately prior to and during the check referred to in Clause 1(a) of Schedule 4, Lessee, at its own expense, shall make the Aircraft and the Aircraft Documents available to Lessor’s representatives at the Return Location for inspection (“Final Inspection”) in order to verify that the condition of the Aircraft complies with the provisions of this Agreement. The period allowed for the Final Inspection shall have such duration as to permit the conduct by Lessor, at Lessee’s expense, of the following: (a) inspection of the Aircraft structure and Parts during which inspection Lessee shall open all inspection doors and panels specified by Lessor which are normally opened in the course of a C-Check or its equivalent under the Maintenance Program and Lessee shall open any other doors or panels or other zonal areas specified by Lessor if Lessor, acting in good faith, can show reasonable grounds (based on the physical appearance or condition of the Aircraft and/or information contained in the Aircraft Documents) for believing that such opening will result in corrosion being revealed; (b) acceptance flight or flights (following the Manufacturer’s acceptance procedures for used aircraft) with Lessor’s representatives as technical observers, of such duration as is necessary (but not less than two hours or more than three hours) to demonstrate the satisfactory operation of the Aircraft, its equipment and systems; (c) inspection of the Engines including, without limitation, (i) a full cold and hot section video tape borescope inspection of the Engines and (ii) full on-wing Engine maximum power assurance runs (including condition, acceleration, vibration monitoring and bleed valve scheduling checks) on each Engine to successfully demonstrate (x) take-off power in accordance with the limits shown in Manufacturer’s manual and (y) that each Engine will have a remaining hot day takeoff EGT margin sufficient to permit the operation of such Engine for the Flight Hours and Cycles set forth in Schedule 4, Redelivery Conditions (based on a review of the Engine historical and technical records, borescope inspection results, power assurance run results, and tren...

Related to Inspection; Corrections; Additional Work

  • Inspection/Testing In order to assess Supplier’s work quality and/or compliance with this Order, upon reasonable notice by Buyer: (a) all goods, materials and services related to the items purchased hereunder, including, raw materials, components, assemblies, work in process, tools and end products shall be subject to inspection and testing by Buyer, its customer, representative or regulatory authorities at all places, including sites where the goods are made or located or the services are performed, whether at Supplier’s premises or elsewhere; and (b) all of Supplier’s facilities, books and records relating to this Order shall be subject to inspection by Buyer or its designee. If specific Buyer and/or Buyer’s customer tests, inspection and/or witness points are included in this Order, the goods shall not be shipped without an inspector’s release or a written waiver of test/inspection/witness with respect to each such point; however, Buyer shall not be permitted to unreasonably delay shipment; and Supplier shall notify Buyer in writing at least twenty (20) days prior to each of Supplier’s scheduled final and, if applicable, intermediate test/inspection/witness points. Supplier agrees to cooperate with such/audit inspection including, completing and returning questionnaires and making available its knowledgeable representatives. Buyer’s failure to inspect or test goods, materials or services or Buyer’s failure to reject or detect defects by inspection or testing shall not relieve Supplier from its warranty obligations or any of its other obligations or responsibilities under this Order. Supplier agrees to provide small business as well as minority and/or women owned business utilization and demographic data upon request.

  • Project Completion Report At the completion of construction and once a Project is placed in service, the Subrecipient must submit a Project Completion Report that includes the total number of units built and leased, affordable units built and leased, DR-MHP units built and leased, an accomplishment narrative, and the tenants names, demographics and income for each DR-MHP unit.

  • Equipment Testing and Inspection 2.1.1 The Interconnection Customer shall test and inspect its Small Generating Facility and Interconnection Facilities prior to interconnection. The Interconnection Customer shall notify the NYISO and the Connecting Transmission Owner of such activities no fewer than five Business Days (or as may be agreed to by the Parties) prior to such testing and inspection. Testing and inspection shall occur on a Business Day. The Connecting Transmission Owner may, at its own expense, send qualified personnel to the Small Generating Facility site to inspect the interconnection and observe the testing. The Interconnection Customer shall provide the NYISO and Connecting Transmission Owner a written test report when such testing and inspection is completed. The Small Generating Facility may not commence parallel operations if the NYISO, in consultation with the Connecting Transmission Owner, finds that the Small Generating Facility has not been installed as agreed upon or may not be operated in a safe and reliable manner. 2.1.2 The NYISO and Connecting Transmission Owner shall each provide the Interconnection Customer written acknowledgment that it has received the Interconnection Customer’s written test report. Such written acknowledgment shall not be deemed to be or construed as any representation, assurance, guarantee, or warranty by the NYISO or Connecting Transmission Owner of the safety, durability, suitability, or reliability of the Small Generating Facility or any associated control, protective, and safety devices owned or controlled by the Interconnection Customer or the quality of power produced by the Small Generating Facility.

  • Inspection; Compliance Lessor and Lessor's Lender(s) (as defined in Paragraph 8.3(a)) shall have the right to enter the Premises at any time, in the case of an emergency, and otherwise at reasonable times, for the purpose of inspecting the condition of the Premises and for verifying compliance by Lessee with this Lease and all Applicable Laws (as defined in Paragraph 6.3), and to employ experts and/or consultants in connection therewith and/or to advise Lessor with respect to Lessee's activities, including but not limited to the installation, operation, use, monitoring, maintenance, or removal of any Hazardous Substance or storage tank on or from the Premises. The costs and expenses of any such inspections shall be paid by the party requesting same, unless a Default or Breach of this Lease, violation of Applicable Law, or a contamination, caused or materially contributed to by Lessee is found to exist or be imminent, or unless the inspection is requested or ordered by a governmental authority as the result of any such existing or imminent violation or contamination. In any such case, Lessee shall upon request reimburse Lessor or Lessor's Lender, as the case may be, for the costs and expenses of such inspections.

  • Construction Completion The related Construction shall have been completed substantially in accordance with the related Plans and Specifications, the related Deed and all Applicable Laws, and such Leased Property shall be ready for occupancy and operation. All fixtures, equipment and other property contemplated under the Plans and Specifications to be incorporated into or installed in such Leased Property shall have been substantially incorporated or installed, free and clear of all Liens except for Permitted Liens.

  • Inspection Checklist (Check one)

  • ADDITIONAL SPECIAL CONTRACT CONDITIONS Special Contract Conditions revisions: the corresponding subsections of the Special Contract Conditions referenced below are replaced in their entirety with the following:

  • Notice to Proceed - Site Improvements The Recipient shall not commence, or cause to be commenced, any site improvements or other work on the Land until the Director has issued a Notice to Proceed to the Recipient. Such Notice to Proceed will not be issued until the Director is assured that the Recipient has complied with all requirements for the approval of a grant under Revised Code Sections 164.20 through 164.27 and has completed any land acquisition required by the Project. A Notice to Proceed shall be required for all Project prime contractors or direct procurement initiated by the Recipient following execution of this Agreement.

  • Selection of Subcontractors, Procurement of Materials and Leasing of Equipment The contractor shall not discriminate on the grounds of race, color, religion, sex, national origin, age or disability in the selection and retention of subcontractors, including procurement of materials and leases of equipment. The contractor shall take all necessary and reasonable steps to ensure nondiscrimination in the administration of this contract. a. The contractor shall notify all potential subcontractors and suppliers and lessors of their EEO obligations under this contract. b. The contractor will use good faith efforts to ensure subcontractor compliance with their EEO obligations.

  • Commercial Operation Date Testing and Modifications Prior to the Commercial Operation Date, the Connecting Transmission Owner shall test the Connecting Transmission Owner’s Attachment Facilities and System Upgrade Facilities and System Deliverability Upgrades and Developer shall test the Large Generating Facility and the Developer Attachment Facilities to ensure their safe and reliable operation. Similar testing may be required after initial operation. Developer and Connecting Transmission Owner shall each make any modifications to its facilities that are found to be necessary as a result of such testing. Developer shall bear the cost of all such testing and modifications. Developer shall generate test energy at the Large Generating Facility only if it has arranged for the injection of such test energy in accordance with NYISO procedures.