Repair and Restoration If the Mortgaged Property can be repaired or restored to substantially the same condition as existed prior to the event causing such damage or destruction, or the effect of the combination can be relieved so that the status of the Mortgaged Property will be restored to substantially the same status as existed prior to the event causing such condemnation, without, in either case, jeopardizing repayment of the principal of and interest on the Indebtedness, and Grantor elects to repair and restore the Mortgaged Property, the Proceeds will be deposited with the Beneficiary and held in a special escrow account of the Beneficiary to be applied to repair, replace, or improve the Mortgaged Property. Proceeds held in such escrow account held by the Beneficiary shall be disbursed by the Beneficiary for the repair, replacement, or improvement of the Mortgaged Property upon receipt by the Beneficiary from the Grantor of (A) an architect's certificate with each draw submitted by Grantor stating that the repairs, replacements, or improvements completed through the date of such draw are practical and necessary, have been completed in accordance with plans and specifications previously provided to the Beneficiary, and that such repairs, replacements, or improvements comply with all applicable statutes, codes, and regulations; (B) a certificate stating that sufficient moneys are available to cause such repair, restoration, replacements, or improvements; (C) requisitions and certificates from the Grantor in the form reasonably acceptable to the Beneficiary; (D) applicable lien waivers; and (E) an endorsement to the title insurance policy insuring the continued priority of the lien of this Mortgage. The Beneficiary shall retain ten percent (10%) of the requested disbursements to be disbursed upon final completion of the repairs, replacements, or improvements as certified by an independent architect and receipt of waivers of liens and an endorsement to the title policy for the Mortgaged Property insuring the continued priority of the lien of this Mortgage. If at any time during the restoration, the Proceeds are less than the estimated cost to repair the Mortgaged Property, the Grantor shall pay an amount equal to the shortfall. The Grantor may rely upon the advice of architects, engineers, accountants, financial consultants, attorneys, or other experts selected by it in the foregoing matters. Any Proceeds in excess of the amount required to repair and restore the Mortgaged Property under this Alternative A, at the direction of the Grantor, shall either be used to prepay the Indebtedness or disbursed to the Grantor.
Ownership Removal Surrender and Restoration 8.4.1 Subject to Lessor’s right to require removal or elect ownership as hereinafter provided, all Alterations and Utility Installations made by Lessee shall be the property of Lessee but considered a part of the Premises. Lessor may, at any time, elect in writing to be the owner of all or any specified part of the Lessee Owned Alterations and Utility Installations; provided, however, that the modular clean room and the permanent electrical generator installed adjacent to the Premises (as shown on Exhibit A) shall remain the property of the Lessee and which the Lessee agrees to remove from the premises upon Lease termination. Unless otherwise instructed per Section 8.4.2 hereof, all Lessee Owned Alterations and Utility Installations shall, at the expiration or termination of this Lease, become the property of Lessor and be surrendered by Lessee with the Premises.
Environmental Site Assessment Perform in accordance with the City Design Manual and other City requirements as designated in writing by the Director.
Phase I a. In Phase I, the project will be connected as a tap to the Transmission Owner’s 230kV transmission line MWP-2 via one 230kV circuit breaker in series with one of two ring bus breakers for stuck breaker protection (one in each direction) and a tie-line breaker, as shown on the one-line diagram labeled CL-E-IA-01 attached to this Appendix A as Figure 1. The changes to the existing MWP-2 line protection for this arrangement are described in Phase I System Upgrades in Section II of this Appendix A.
Environmental Site Assessments Upon request by Landlord during the Term of this Lease, prior to the exercise of any renewal Term and/or prior to vacating the Premises, Tenant will obtain and submit to Landlord an environmental site assessment from an environmental consulting company reasonably acceptable to Landlord.
Underground Storage Tanks In accordance with the requirements of Section 3(g) of the D.C. Underground Storage Tank Management Act of 1990, as amended by the District of Columbia Underground Storage Tank Management Act of 1990 Amendment Act of 1992 (D.C. Code § 8-113.01, et seq.) (collectively, the “UST Act”) and the applicable D.C. Underground Storage Tank Regulations, 20 DCMR Chapter 56 (the “UST Regulations”), District hereby informs the Developer that it has no knowledge of the existence or removal during its ownership of the Property of any “underground storage tanks” (as defined in the UST Act). Information pertaining to underground storage tanks and underground storage tank removals of which the D.C. Government has received notification is on file with the District Department of the Environment, Underground Storage Tank Branch, 00 X Xxxxxx, X.X., Xxxxx Xxxxx, Xxxxxxxxxx, X.X., 00000, telephone (000) 000-0000. District’s knowledge for purposes of this Section shall mean and be limited to the actual knowledge of Xxxxxx Xxxxx, Property Acquisition and Disposition Division of the Department of Housing and Community Development, telephone no. (000) 000-0000. The foregoing is set forth pursuant to requirements contained in the UST Act and UST Regulations and does not constitute a representation or warranty by District.
Phase II A small portion of the work for the Phase II modifications to the Plattsburgh Substation will be performed by Transmission Owner, and the remainder will be performed by Clinton and Xxxxxxxxx. A detailed definition of the specific scope for Transmission Owner and Clinton and Xxxxxxxxx including interface points shall be defined during the design phase and, as such documents become available, copies will be delivered to the NYISO, Transmission Owner, Noble Altona Windpark, LLC and Marble River, LLC. The full scope includes the installation of wave traps, CCVT’s and modifications and/or additions to relaying on the MWP-1 and MWP- 2 lines. These lines will be reconfigured at the completion of Phase II to connect to Xxxxx and Xxxxxxx Substations on MWP-1 and the Xxxx Substation on MWP-2. Clinton and Xxxxxxxxx will design the upgrades and purchase the materials based on the outline specification that was prepared and issued by Transmission Owner. The work to be performed by Clinton and Xxxxxxxxx will include both the materials for the exterior and interior installations and items for Transmission Owner installation inside the control building in existing relay panels and communication racks. In addition, Clinton and Xxxxxxxxx will be responsible for the exterior and interior construction work and will provide construction management services in coordination with Transmission Owner. The civil design for the foundations and the electrical design for the cable runs to the control room will be designed by, as approved by Transmission Owner, and installed under the supervision and control of Clinton and Xxxxxxxxx. The equipment will be selected and procured in accordance with the specifications developed during the detailed engineering phase, copies of which shall be furnished to the NYISO, Transmission Owner, Noble Altona Windpark, LLC and Marble River, LLC. The construction of the foundations, structures, wave traps, CCTV and cable runs into the control building to the termination cabinets will be completed by Clinton and Xxxxxxxxx. The work at the Plattsburgh Substation will be installed under Transmission Owner’s CPP-1. Transmission Owner will provide Protection and Controls Engineering, install and terminate wiring from the termination cabinets to the control panels and relays, install relays and equipment in the existing panels, and will commission such work inside the 230kV control building. Transmission Owner will develop the communications protocols and data flow over the circuits.
Completion Date The Work under this Contract shall be completed by midnight of the date required in the Contract as the Material Completion and Occupancy Date unless extended by approved requests for extension of time.
Notice; Restoration If the Property is damaged or destroyed, in whole or in part, by fire or other casualty (a “Casualty”), Borrower shall give prompt notice thereof to Lender. Following the occurrence of a Casualty, Borrower, regardless of whether insurance proceeds are available, shall promptly proceed to restore, repair, replace or rebuild the Property in accordance with Legal Requirements to be of at least equal value and of substantially the same character as prior to such damage or destruction.