Smart Plant Instrumentation Sample Clauses

Smart Plant Instrumentation. One database based on Intergraph Smart Plant Instrumentation (SPI) shall be developed and maintained for the RRE project by each EPC CONTRACTOR. This shall include database for packages. SPI shall be utilized to generate the following deliverables: Instrument Index Instrument Datasheets ICS and subsystem I/O counts Instrument Interconnection Wiring Diagrams Instrument Loop Diagrams Instrument Segment Diagrams Instrument Index population shall be based on CONTRACTOR detailed design P&IDs and on Bubble Loop representations as defined in Project Guide for Short Form Instrument P&ID Loop Representations 5578-TEC-IU-003. These shall be further developed and expanded as necessary during EPC execution phase. The Instrument Index shall include all instruments as defined on Process, Utility, Auxiliary and Licensor P&IDs, as well as requirements from Vendor Packages. Upon completion of RRE project the electronic SPI database shall be supplied to COMPANY as a Watcom file. SPI Version to be used will be confirmed by COMPANY during the detail engineering phase. The O&Us EPC shall be responsible for the co-ordination of SPI throughout the project. Population of SPI shall be inline with INTools Implementation guide 5578-TEC-IU-002. In addition to the fields populated during FEED phase of the RRE project, the following additional fields shall be populated as a minimum by CONTRACTORS during detailed design phase: Signal Type (Voltage free, pulse, 120 VAC, 24 VDC) Valve Control action (direct/reverse) Parallel area (to avoid parallel equipment being allocated to same I/O card) FF Segment no. Valve Criticality for allocation to FF segments Long/Short format Service Description Alarm and Trip Setpoints Alarm Priorities Instrument Engineering Units and Range Signals that shall be Redundant (e.g. DCS AO) Instrument Manufacturer Instrument Model no. Transducer range (for calibration of transmitters by vendor, generally required for D/P level transmitters) MR no. ILD/ISD drawing no. Instrument Location drawing no. Instrument mounting detail drawing no. Instrument Hook up drawing no. The data transfer between CONTRACTOR and ICV shall be carried out in two major stages, the hardware freeze stage and the software freeze stage. During detailed design the O&Us CONTRACTOR shall finalize the required fields to be populated for hardware and software freeze. The O&Us CONTRACTOR shall also be responsible for definition of SPI data exchange process with ICV. The data exchange process shall ...
AutoNDA by SimpleDocs

Related to Smart Plant Instrumentation

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Developer Attachment Facilities Developer shall design, procure, construct, install, own and/or control the Developer Attachment Facilities described in Appendix A hereto, at its sole expense.

  • Developer’s Attachment Facilities (“DAF”). Developer shall, at its expense, design, procure, construct, own and install the DAF, as set forth in Appendix A hereto.

  • Interconnection Agreement On or before December 31, 2015, Wholesale Market Participant must enter into an Interconnection Agreement with the Transmission Owner in order to effectuate the WMPA. Wholesale Market Participant shall demonstrate the occurrence of each of the foregoing milestones to Transmission Provider’s reasonable satisfaction. Transmission Provider may reasonably extend any such milestone dates, in the event of delays that Wholesale Market Participant (i) did not cause and (ii) could not have remedied through the exercise of due diligence. If (i) the Wholesale Market Participant suspends work pursuant to a suspension provision contained in an interconnection and/or construction agreement with the Transmission Owner or (ii) the Transmission Owner extends the date by which Wholesale Market Participant must enter into an interconnection agreement relative to this WMPA, and (iii) the Wholesale Market Participant has not made a wholesale sale under this WMPA, the Wholesale Market Participant may suspend this WMPA by notifying the Transmission Provider and the Transmission Owner in writing that it wishes to suspend this WMPA, with the condition that, notwithstanding such suspension, the Transmission System shall be left in a safe and reliable condition in accordance with Good Utility Practice and Transmission Provider’s safety and reliability criteria. Wholesale Market Participant’s notice of suspension shall include an estimated duration of the suspension period and other information related to the suspension. Pursuant to this section 3.1, Wholesale Market Participant may request one or more suspensions of work under this WMPA for a cumulative period of up to a maximum of three years. If, however, the suspension will result in a Material Modification as defined in Part I, Section 1.18A.02 of the Tariff, then such suspension period shall be no greater than one (1) year. If the Wholesale Market Participant suspends this WMPA pursuant to this Section 3.1 and has not provided written notice that it will exit such suspension on or before the expiration of the suspension period described herein, this WMPA shall be deemed terminated as of the end of such suspension period. The suspension time shall begin on the date the suspension is requested or on the date of the Wholesale Market Participant’s written notice of suspension to Transmission Provider, if no effective date was specified. All milestone dates stated in this Section 3.1 shall be deemed to be extended coextensively with any suspension period permitted pursuant to this provision.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Attachment Facilities Not applicable, because there are no CTOAFs for the Merchant Transmission Facility that are covered by this Agreement.

  • Construction Phase Services 3.1.1 – Basic Construction Services

  • Project Documentation All documentation provided to the City other than Project drawings shall be furnished on a Microsoft compatible compact disc.

  • Joint Network Implementation and Grooming Process Upon request of either Party, the Parties shall jointly develop an implementation and grooming process (the “Joint Grooming Process” or “Joint Process”) which may define and detail, inter alia:

  • Construction Management Plan Contractor shall prepare and furnish to the Owner a thorough and complete plan for the management of the Project from issuance of the Proceed Order through the issuance of the Design Professional's Certificate of Material Completion. Such plan shall include, without limitation, an estimate of the manpower requirements for each trade and the anticipated availability of such manpower, a schedule prepared using the critical path method that will amplify and support the schedule required in Article 2.1.5 below, and the Submittal Schedule as required in Article 2.2.3. The Contractor shall include in his plan the names and resumés of the Project Superintendent, Project Manager and the person in charge of Safety.

Time is Money Join Law Insider Premium to draft better contracts faster.