Steam Turbine Sample Clauses

Steam Turbine a. Erect, install, assemble and perform initial and final alignment of the back pressure steam turbine including the generator and the excitation system. This Work includes motors, pumps, filter, supports, valves, instrumentation, ducts and piping, pipe supports, pipe fittings and pipe accessories, insulation, guards, covers. b. The steam turbine will be provided in three major components: o Steam turbine skid, including lube oil system. o Generator and excitation system o Related valves, controls and other accessories (not assembled together, supplies as loose items). Contractor shall perform initial and final alignment of the turbine &generator in accordance with Vendor's written instructions. c. Perform tests of turbine system according to relevant specifications, including pressure tests for leak checks. Contractor will also flush the lubrication and oil system including all related piping and clean field-installed lines. d. Erect, install and test cooling auxiliary system including piping, coolers, fans, pumps and all other required equipment and materials. e. Apply top layer of paint on equipment and piping of un-insulated or exposed steel surfaces.
AutoNDA by SimpleDocs
Steam Turbine. (a) The steam turbine[s] shall be of a proven design, directly coupled to a 50 Hz generator. Design criteria shall be applied for a long creep life, cyclic duty and fast start-up. Last stage blade materials and exhaust steam wetness shall be selected with an objective to minimise blade erosion. (b) The steam turbine[s] shall be installed with an acoustic, ventilated enclosure. If provided, the turbine house shall incorporate fire detection and protection facilities. (c) The steam turbine exhaust and condenser shall be in accordance with the manufacturer’s standard design.
Steam Turbine. The turbine shall be operated in condensation mode. The back pressure at the turbine outlet shall be no more than 0.7 bar(a). The energy content of the steam shall be converted to electricity with a conversion efficiency of no less than 20% when operating within the Capacity Diagram and shall be computed as follows: P / (Q * (hexit - hfeed) * Oh)  0.2 Q is the steam flow (kg/sec.) passed from the boiler to the inlet of the steam turbine, which shall be continuously monitored by ProjectCo. Oh is the weekly turbine operation time measured in hours. (hexit - hfeed) is the difference between steam enthalpy (kJ/kg) at the boiler outlet (exit) and the enthalpy (kJ/kg) of the feed water in the feed water tank. The values of hexit and hfeed shall be based on ProjectCo’s monitoring of steam pressure and temperature at boiler outlet and the feed water temperature and pressure in the feed water tank. P is the weekly electricity production delivered to Manx Electricity Authority measured in kWh. This Requirement for conversion efficiency shall apply at all times during the Operating Period and shall at the Department's Representative's request be calculated on a weekly basis.

Related to Steam Turbine

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Interconnection Agreement Seller shall comply with the terms and conditions of the Interconnection Agreement.

  • Construction Phase Services 3.1.1 – Basic Construction Services

  • Interconnection 2.1 This section applies to linking with suppliers providing public telecommunications transport networks or services in order to allow the users of one supplier to communicate with users of another supplier and to access services provided by another supplier, where specific commitments are undertaken.

  • Production Phase contract period in which the Development and the Production are to be performed.

  • Fabrication Making up data or results and recording or reporting them.

  • Equipment Cleaning (a) Areas, known by Forest Service prior to timber sale advertisement, that are infested with invasive species of concern are shown on Sale Area Map. A current list of invasive species of concern and a map showing the extent of known infestations is available at the Forest Supervisor’s Office. For purposes of this provision, “Off-Road Equipment” includes all logging and construction machinery, except for log trucks, chip vans, service vehicles, water trucks, pickup trucks, cars, and similar vehicles.

  • Commissioning Commissioning tests of the Interconnection Customer’s installed equipment shall be performed pursuant to applicable codes and standards. The ISO and Connecting Transmission Owner must be given at least five Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.

  • Construction Completion The related Construction shall have been completed substantially in accordance with the related Plans and Specifications, the related Deed and all Applicable Laws, and such Leased Property shall be ready for occupancy and operation. All fixtures, equipment and other property contemplated under the Plans and Specifications to be incorporated into or installed in such Leased Property shall have been substantially incorporated or installed, free and clear of all Liens except for Permitted Liens.