SUPER BUILT-UP Sample Clauses

SUPER BUILT-UP. AREAaccording to the context shall mean and include the Built-Up Area of any Unit And shall include the proportionate share of the areas of the Common Areas in the Housing Complex, attributable to such Unit as shall be determined by the Promoter in its absolute discretion. It is clarified that Super Built-up Area has been given only for reference sake and has nothing to do with the pricing or other aspects of the said Unit agreed to be purchased by the Allottee.
AutoNDA by SimpleDocs
SUPER BUILT-UP. AREA : shall include the built up area of the Unit and proportionate share of stair head room, lift machine room, service unit of ground floor, fire water pump, U.G. ring for hydrant, overhead and/or Underground fire reservoir, fire refuge platforms, pump rooms, septic tank, domestic water pump, Overhead domestic water tank, fire duct, electrical duct, lift service duct, shafts, lofts and other infrastructure area including area for common purpose and mandatory open space in the said building.
SUPER BUILT-UP. AREA shall mean the Built-up Area of any Unit together with thickness of the outer walls provided that in case of the wall being shared with any adjacent unit 50% thereof further together with proportionate undivided share of the area comprised in all the common areas parts and portions and it is expressly agreed by and between the parties hereto that the determination of the Super Built-up Area of any unit by the Architect shall be conclusive and binding on the parties.

Related to SUPER BUILT-UP

  • As-Builts Seller shall provide final as-built drawings of the Seller-Owned Interconnection Facilities within 30 Days of the successful completion of the Acceptance Test.

  • Pendahuluan Industri perbankan syari’ah di Indonesia tengah memasuki fase growth (pertumbuhan) xxx sangat membutuhkan kepercayaan xxx loyalitas masyarakat untuk terus meningkatkan produktivitasnya. Kepercayaan xxx loyalitas mutlak dibutuhkan untuk memasuki fase maturity perbankan syariah dalam menghadapi kompetisi global. Kepercayaan xxx loyalitas tidak dapat diperoleh tanpa adanya produk- produk yang mampu menjawab kebutuhan masyarakat. Produk bank syariah sudah semestinya mampu memenuhi seluruh komponen masyarakat, baik dalam produk funding, financing, xxx services. Oleh karenanya, inovasi produk bank syariah menjadi syarat mutlak sebagai indikator bahwa bank syariah mampu beradaptasi dengan kebutuhan manusia modern. Inovasi produk merupakan salah satu unsur penting untuk dapat menjaga sustainabilitas perusahaan. Inovasi produk merepresentasikan kemampuan perusahaan untuk dapat memenuhi kebutuhan pasar sekaligus sebagai upaya untuk memperoleh keuntungan perusahaan. Bank syariah pada dasarnya telah melakukan serangkaian upaya inovasi, salah satunya adalah dengan melakukan “rekayasa” (engineering) terhadap akad- akad dalam fiqh muamalah. Beberapa akad dalam fiqh muamalah tidak begitu saja diadopsi oleh perbankan syariah, namun juga “diadaptasikan” dengan kebutuhan masyarakat terhadap xxxx-xxxx perbankan. Rekayasa xxx adaptasi ini memang sebuah keniscayaan, karena jika adopsi dilakukan secara apa adanya maka produk bank syariah diragukan dapat memberikan manfaat yang tepat bagi masyarakat. Prinsip keleluasan bermuamalah dalam Islam merupakan modal utama untuk menghadapi kompleksitas permasalahan ekonomi serta besarnya tuntutan masyarakat akan peran perbankan syariah.1 Dalam rangka memenuhi kebutuhan masyarakat xxx mengembangkan industri perbankan xxx keuangan xxxx xxxx kompetitif, inovasi dalam berbisnis yang dilakukan oleh perbankan syariah melalui serangkaian adaptasi tersebut memang sudah menjadi tuntutan bisnis. Sebagai contoh dapat dikemukakan xxxxxx xxxx kartu kredit syariah, asuransi syariah, obligasi syariah, FX iB, xxx Islamic Swap. Produk-produk dalam kegiatan keuangan syariah tersebut mengandung beberapa akad. Sebagai contoh, dalam transaksi kartu kredit syariah terdapat akad ijarah, qardh, xxx kafalah. Obligasi syariah mengandung sekurang-kurangnya akad mudharabah (atau ijarah) xxx wakalah, serta terkadang disertai kafalah atau wa’d. Islamic swap mengandung beberapa kali akad tawarruq, bay‘, wakalah, xxxxx, xxx terkadang disertai wa’d.2 Dalam setiap transaksi, akad-akad tersebut dilakukan secara bersamaan atau setidak-tidaknya setiap akad yang terdapat dalam suatu produk tidak bisa ditinggalkan, karena kesemuanya merupakan satu kesatuan. Transaksi seperti 1 Xxxxxx Xxxxx Xxxxxx, “Konstruksi Akad dalam Pengembangan Produk Perbankan Syariah di Indonesia”, Al-‘Adalah, Vol. 12, No. 3 (Juni, 2015), 493. 2 Xxxxxxxxx Xxxxxxx, “Multiakad dalam Transaksi Syariah Kontemporer pada Lembaga Keuangan Syariah di Indonesia”, Al-Iqtishad, Vol. 3, No. 1 (Januari, 2011), 156. inilah yang dikenal dengan istilah multiakad (Indonesia) atau hybrid contract (Inggris) atau al-’uqud al-murakkabah (Arab). Hybrid contract merupakan perbincangan yang masih hangat dikalangan para cendikiawan muslim untuk menentukan keabsahan hukumnya. Pendapat pertama mengatakan hukumnya mubah berdasar kaidah fiqh al-ashlu fi al-mu’amalat al-ibahah (hukum asal muamalah adalah boleh). Pendapat kedua mengharamkan berdasarkan dengan hadits-hadits yang mengharamkan dua jual beli dalam satu jual beli (bai’ataini fi bai’atin), atau mengharamkan dua akad dalam satu akad (shafqatain fi shafqatin).3 Sebagai entitas bisnis yang menjadi bagian penting dalam sistem ekonomi syariah sebagai induknya, tentunya industri perbankan syariah tidak boleh keluar dari nilai-nilai syariah. Melakukan inovasi memang tuntutan bisnis, namun menjaga shariah compliance juga menjadi kewajiban bagi setiap pelaku bisnis syariah, tidak terkecuali perbankan syariah. Profit-oriented hanya boleh dijadikan sebagai media (tool) untuk mencapai tujuan (goal), yaitu benefit-oriented. Produk bank syari’ah seyogyanya memiliki multi benefit, yaitu: material benefit, emotional benefit, xxx spiritual benefit.4 Mengacu pada kondisi tersebut, maka inovasi produk perbankan syariah setidaknya memerhatikan inovasi dalam dua dimensi, yaitu dimensi ekonomi xxx dimensi sosial. Inovasi dalam dimensi ekonomi artinya bahwa produk perbankan syariah harus mampu menghadirkan produk yang sesuai dengan kebutuhan masyarakat, sehingga bank syariah menjadi pilihan utama masyarakat. Jika hal ini dapat dilakukan, maka fungsi-fungsi bank syariah akan mampu memainkan perannya sebagai intermediary institution. Pada dimensi sosial, sebagai produsen jasa keuangan syariah, bank syariah bertanggung jawab untuk melakukan edukasi terhadap perilaku masyarakat. Bank syariah xxx masyarakat xxxxxx melekat xxx memengaruhi satu dengan yang lain. Pada satu sisi, bank syariah melalui pola inovasinya harus mampu “men-syariah- kan” perilaku masyarakat, khususnya yang berhubungan dengan lembaga 3 Najamuddin, “Al-‘Uqud Al-Murakkabah dalam Perspektif Ekonomi Syariah”, Jurnal Syariah, Vol. 2, No. 2 (Oktober, 2013), 6.

  • Power System Stabilizers The Developer shall procure, install, maintain and operate Power System Stabilizers in accordance with the requirements identified in the Interconnection Studies conducted for Developer’s Large Generating Facility. NYISO and Connecting Transmission Owner reserve the right to reasonably establish minimum acceptable settings for any installed Power System Stabilizers, subject to the design and operating limitations of the Large Generating Facility. If the Large Generating Facility’s Power System Stabilizers are removed from service or not capable of automatic operation, the Developer shall immediately notify the Connecting Transmission Owner and NYISO. The requirements of this paragraph shall not apply to wind generators.

  • As-Built Plans Within thirty (30) days after completion of Tenant’s Changes requiring the submission of plans to Landlord, Tenant shall furnish to Landlord a complete set of “as-built” plans and specifications.

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and PCS, PCS shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks and the Entrance Facility, on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs. 2.4.2 Prior to ordering any Two-Way Interconnection Trunks from Verizon, PCS shall meet with Verizon to conduct a joint planning meeting (“Joint Planning Meeting”). At that Joint Planning Meeting, each Party shall provide to the other Party originating Centium Call Second (Hundred Call Second) information, and the Parties shall mutually agree on the appropriate initial number of Two-Way End Office and Tandem Interconnection Trunks and the interface specifications at the Point of Interconnection (POI). Where the Parties have agreed to convert existing One-Way Interconnection Trunks to Two-Way Interconnection Trunks, at the Joint Planning Meeting, the Parties shall also mutually agree on the conversion process and project intervals for conversion of such One-Way Interconnection Trunks to Two-Way Interconnection Trunks. 2.4.3 Two-Way Interconnection Trunks shall be from a Verizon End Office or Tandem to a mutually agreed upon POI. 2.4.4 On a semi-annual basis, PCS shall submit a good faith forecast to Verizon of the number of End Office and Tandem Two-Way Interconnection Trunks that PCS anticipates Verizon will need to provide during the ensuing two (2) year period to carry traffic from PCS to Verizon and from Verizon to PCS. PCS’s trunk forecasts shall conform to the Verizon CLEC trunk forecasting guidelines as in effect at that time. 2.4.5 The Parties shall meet (telephonically or in person) from time to time, as needed, to review data on End Office and Tandem Two-Way Interconnection Trunks to determine the need for new trunk groups and to plan any necessary changes in the number of Two-Way Interconnection Trunks. 2.4.6 Two-Way Interconnection Trunks shall have SS7 Common Channel Signaling. The Parties agree to utilize B8ZS and Extended Super Frame (ESF) DS1 facilities, where available. 2.4.7 With respect to End Office Two-Way Interconnection Trunks, both Parties shall use an economic Centium Call Second (Hundred Call Second) equal to five (5). 2.4.8 Two-Way Interconnection Trunk groups that connect to a Verizon access Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.005 during the average time consistent busy hour. Two-Way Interconnection Trunk groups that connect to a Verizon local Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.01 during the average time consistent busy hour. Verizon and PCS shall engineer Two-Way Interconnection Trunks using BOC Notes on the LEC Networks SR-TSV-002275. 2.4.9 The performance standard for final Two-Way Interconnection Trunk groups shall be that no such Interconnection Trunk group will exceed its design blocking objective (B.005 or B.01, as applicable) for three

  • One-Way Interconnection Trunks 2.3.1 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from Onvoy to Frontier, Onvoy, at Xxxxx’s own expense, shall: 2.3.1.1 provide its own facilities for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA; and/or 2.3.1.2 obtain transport for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA (a) from a third party, or, (b) if Frontier offers such transport pursuant to a Frontier access Tariff, from Frontier. 2.3.2 For each Tandem or End Office One-Way Interconnection Trunk group for delivery of traffic from Onvoy to Frontier with a utilization level of less than sixty percent (60%) for final trunk groups and eighty-five percent (85%) for high usage trunk groups, unless the Parties agree otherwise, Onvoy will promptly submit ASRs to disconnect a sufficient number of Interconnection Trunks to attain a utilization level of approximately sixty percent (60%) for all final trunk groups and eighty-five percent (85%) for all high usage trunk groups. In the event Onvoy fails to submit an ASR to disconnect One-Way Interconnection Trunks as required by this Section, Frontier may disconnect the excess Interconnection Trunks or bill (and Onvoy shall pay) for the excess Interconnection Trunks at the rates set forth in the Pricing Attachment. 2.3.3 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from Frontier to Onvoy, Frontier, at Frontier’s own expense, shall provide its own facilities for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA.

  • Porcupine Site Highway 11 and the City of Timmins Thunder Bay and District Toronto/York-Peel

  • Delivery; Acceptance of Premises; Commencement Date Landlord shall use reasonable efforts to deliver the Premises to Tenant on or before the Target Commencement Date in the Tenant Improvement Work Readiness Condition for construction by Tenant of the Tenant Improvements (“Delivery” or “Deliver”). If Landlord fails to timely Deliver the Premises, Landlord shall not be liable to Tenant for any loss or damage resulting therefrom, and this Lease shall not be void or voidable except as provided herein. If Landlord does not Deliver the Premises within 120 days of the Target Commencement Date for any reason other than Force Majeure delays, this Lease may be terminated by Landlord or Tenant by written notice to the other, and if so terminated by either: (a) the Security Deposit, or any balance thereof (i.e., after deducting therefrom all amounts to which Landlord is entitled under the provisions of this Lease), shall be returned to Tenant, and (b) neither Landlord nor Tenant shall have any further rights, duties or obligations under this Lease, except with respect to provisions which expressly survive termination of this Lease. As used herein, the terms “Tenant Improvements” and “Tenant Improvement Work Readiness Condition” shall have the meanings set forth for such terms in the work letter at here to as Exhibit C (the “Work Letter”). If neither Landlord nor Tenant elects to void this Lease within 10 business days of the lapse of such 120 day period (as may be extended by Force Majeure delays), such right to void this Lease shall be waived and this Lease shall remain in full force and effect. Notwithstanding the foregoing, Landlord and Tenant agree that if any Governmental Authority having jurisdiction of the Project, as a result of the COVID-19 outbreak in the United States declares or implements any order or mandate that restricts construction activities in San Diego county (any such order or mandate, a “Government Mandate”), then, to the extent such Government Mandate precludes construction of the Core & Shell (as defined in the Work Letter), the Target Commencement Date shall be delayed 1 day for each day that such a Government Mandate remains in effect and continues to preclude such construction of the Core & Shell. 3115 Xxxxxxxxxx/Erasca - Page 3 The “Commencement Date” shall be date that Landlord Delivers the Premises to Tenant in Tenant Improvement Work Readiness Condition. The “Rent Commencement Date” shall be the date that is 180 days after the Commencement Date (which is anticipated to be February 1, 2022, based on the Target Commencement Date of August 1, 2021); provided, however, that the Rent Commencement Date shall be delayed 1 day for each day after the Commencement Date that a Government Mandate that restricts construction activities in San Diego county is in effect to the extent that such Government Mandate precludes such construction of the Tenant Improvements. Upon request of Landlord, Tenant shall execute and deliver a written acknowledgment of the Commencement Date, the Rent Commencement Date and the expiration date of the Term when such are established in the form of the “Acknowledgement of Commencement Date” attached to this Lease as Exhibit D; provided, however, Tenant’s failure to execute and deliver such acknowledgment shall not affect Landlord’s rights hereunder. The “Term” of this Lease shall be the Base Term, as defined above on the first page of this Lease. Except as set forth in the Work Letter: (i) Tenant shall accept the Premises in their condition as of the Commencement Date; (ii) Landlord shall have no obligation for any defects in the Premises; and (iii) Tenant’s taking possession of the Premises shall be conclusive evidence that Tenant accepts the Premises and that the Premises were in good condition at the time possession was taken. Any occupancy of the Premises by Tenant before the Commencement Date shall be subject to all of the terms and conditions of this Lease, excluding the obligation to pay Base Rent and Operating Expenses. Notwithstanding the foregoing, for the period of 365 consecutive days after the Commencement Date, Landlord shall, at its sole cost and expense (which shall not constitute an Operating Expense), be responsible for any repairs that are required to be made to Building Systems (as defined in Section 13), serving the Premises unless Tenant or any Tenant Party was responsible for the cause of such repair or Tenant was responsible for the construction of such Building Systems as part of the Tenant Improvements, in which case Tenant shall pay the cost. In addition, Tenant shall be entitled to the benefit of any warranties issued to Landlord in connection with the Core & Shell for the terms of such warranties to the extent affecting the Premises. Tenant agrees and acknowledges that neither Landlord nor any agent of Landlord has made any representation or warranty with respect to the condition of all or any portion of the Premises or the Project, and/or the suitability of the Premises or the Project for the conduct of Tenant’s business, and Tenant waives any implied warranty that the Premises or the Project are suitable for the Permitted Use. This Lease constitutes the complete agreement of Landlord and Tenant with respect to the subject matter hereof and supersedes any and all prior representations, inducements, promises, agreements, understandings and negotiations which are not contained herein. Landlord in executing this Lease does so in reliance upon Tenant’s representations, warranties, acknowledgments and agreements contained herein.

  • Gross Beta Flags A = Result acceptable, Bias <= +/- 50% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 50% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!