WORK CONTRACTED OUT 2 Sample Clauses

WORK CONTRACTED OUT 2. 08.1 Current Work‌‌‌ 1) The Employer shall not contract out or outsource any work performed by bargaining unit Employees where such work relates to fixed route, fixed schedule bus service, nor where there is work related to the maintenance of the vehicles that deliver such service, except: a) where there is mutual agreement with the local Union; or b) in the case of emergency; or c) where the Employer does not have the appropriate facilities, equipment or staff to complete the work in the time required. 2) In any case, in awarding contracts pursuant to 1 a), b), and c), the Employer will give preference to contractors providing wages and working conditions comparable to the prevailing local Unionized rates for the relevant industry or trade. 3) Performance of warranty work, preparation of new vehicles or new equipment is subject to the terms of the tender specifications and supply contract with the original equipment manufacturer except as modified below. The Employer shall perform maintenance, warranty and installation of new equipment in- house where this can be done with bargaining unit Employees subject to a) below; except as modified below. Under no circumstances shall any mechanical warranty work, as set out above exceed five years in duration where that work is prohibited from being done by bargaining unit members unless there are mechanical design defects that have been identified by the manufacturer. a) Other warranty requirements and opportunities will be reviewed with the local Union and training needs addressed by the Maintenance Consultative Committee to determine if warranty work can be done in-house to the same standards at equivalent or lower cost. b) In any case, where warranty work could be completed effectively in-house, in accordance with a) above, but lack of appropriate certifications by BC Transit Employees could negate the effect of a warranty, BC Transit can have such warranty work performed by the appropriate agents until such time as the Employer can expeditiously arrange to provide training and courses that will furnish bargaining unit Employees with the certification necessary to complete such warranty work. In these cases, where the manufacturer’s agents perform the work at the Employer’s facility, a bargaining unit member will be assigned to accompany and assist the agent as necessary. 4) Services such as dial-a-ride, dispatch, paratransit, custom transit and vanpooling services are beyond the scope of this Article.
AutoNDA by SimpleDocs

Related to WORK CONTRACTED OUT 2

  • Project Completion Date It is agreed between the Parties that the Project Completion Date is <END DATE, YEAR>. If the Project is not completed by such date then, subject to an amendment agreed to between the Parties, Alberta Innovates may elect to terminate this Investment Agreement. In such event, Alberta Innovates will notify the Applicant of its decision to terminate as soon as reasonably practical and shall advise the Applicant of the effective date of termination. Alberta Innovates will have no liability or obligation to reimburse the Applicant for any Project Costs incurred after the effective date of termination and may require the Applicant to return any portions of the Investment which were spent on Ineligible Expenses. Additionally, any portion of the Investment not used and accounted for in accordance with this Agreement as of the Project Completion Date or earlier termination is repayable by the Applicant to AI at AI’s request.

  • Scope of Work For the 2022/2023 Grant Period, the Provider will maintain a victim services program that will be available to provide direct services to victims of crime who are identified by the Provider or are presented to the Provider, as specified in the Provider’s 2022/2023 Grant Application as approved by the OAG and incorporated herein by reference.

  • Project Schedule Construction must begin within 30 days of the date set forth in Appendix A, Page 2, for the start of construction, or this Agreement may become null and void, at the sole discretion of the Director. However, the Recipient may apply to the Director in writing for an extension of the date to initiate construction. The Recipient shall specify the reasons for the delay in the start of construction and provide the Director with a new start of construction date. The Director will review such requests for extensions and may extend the start date, providing that the Project can be completed within a reasonable time frame.

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.

  • Contract Work Contract work means capital project work within existing plant facilities, major maintenance and/or revamp work, plant modifications and/or shutdown work, minor maintenance and/or repair work, breakdown maintenance.

  • Acceptance Tests 11.1 If the Contract provides acceptance tests for Goods and/or the result of Services after their completion and/or delivery to the Purchaser, the acceptance shall only be considered as definitive when such tests have demonstrated the compliance of the Goods and/or the result of the Services to the requirements in the Contract. 11.2 Where the Contract provides for an acceptance procedure in the presence of both parties, at the successful completion of such procedure, the Purchaser shall issue the Supplier with an acceptance certificate which shall authorise the Supplier to invoice the Purchaser for any payment due on such acceptance. 11.3 The Purchaser shall at its discretion be entitled to issue and acceptancecertificate with reserves. The Supplier shall be obliged to remedy any non-conformities within the period set out in the acceptance certificate. Any payment which would otherwise have been due on acceptance may be withheld by the Purchaser in whole or part until the non- conformities underlying the reserves have been remedied.

  • Work Day The standard work day shall be eight (8) consecutive hours of work exclusive of a lunch period in a consecutive twenty-four (24) hour day.

  • Planned Outages Seller shall schedule Planned Outages for the Project in accordance with Good Industry Practices and with the prior written consent of Buyer, which consent may not be unreasonably withheld or conditioned. The Parties acknowledge that in all circumstances, Good Industry Practices shall dictate when Planned Outages should occur. Seller shall notify Buyer of its proposed Planned Outage schedule for the Project for the following calendar year by submitting a written Planned Outage schedule no later than October 1st of each year during the Delivery Term. The Planned Outage schedule is subject to Buyer’s approval, which approval may not be unreasonably withheld or conditioned. Buyer shall promptly respond with its approval or with reasonable modifications to the Planned Outage schedule and Seller shall use its best efforts in accordance with Good Industry Practices to accommodate Xxxxx’s requested modifications. Notwithstanding the submission of the Planned Outage schedule described above, Seller shall also submit a completed Outage Notification Form to Buyer no later than fourteen (14) days prior to each Planned Outage and all appropriate outage information or requests to the CAISO in accordance with the CAISO Tariff. Seller shall contact Buyer with any requested changes to the Planned Outage schedule if Seller believes the Project must be shut down to conduct maintenance that cannot be delayed until the next scheduled Planned Outage consistent with Good Industry Practices. Seller shall not change its Planned Outage schedule without Buyer’s approval, not to be unreasonably withheld or conditioned. Seller shall use its best efforts in accordance with Good Industry Practices not to schedule Planned Outages during the months of July, August, September and October. At Buyer’s request, Seller shall use commercially reasonable efforts to reschedule Planned Outage so that it may deliver Product during CAISO declared or threatened emergency periods. Seller shall not substitute Energy from any other source for the output of the Project during a Planned Outage.

  • Project Work Plan The Statement of Work is the formal document incorporated into the Grant. The Project Work Plan documents how the Grantee will achieve the performance measures outlined in the Grant. Changes to the Statement of Work require an amendment. Project Work Plans may be changed with written approval from PEI and the Grantee.

  • Project Work PURCHASER shall complete the following projects in accordance with the specifications provided in Exhibits B, C, D, E, and F and written instructions from STATE. Project locations are shown on Exhibit A unless otherwise described. PURCHASER shall furnish all material unless otherwise specified.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!