Design Life Sample Clauses

Design Life. The design life of the Permanent Works for civil engineering structures shall be 70 years.
Design Life. All sanitary sewer pipe systems shall be designed and installed with a design life of not less than 50 years.
Design Life. All sanitary sewer pipe systems shall be designed and installed with a design life of not less than 50 years. 5-2.2 Easements‌ Any proposed sewer main located in a dedicated easement on property where a multi- family, (triplex or larger), commercial or industrial buildings can be built, shall be centered within the easement. Easements shall be a minimum of 20 feet in width. Easements are to be accurately located with off sets and dimensions shown on the plan sheets. All easements shall be agreed to between the applicant and the City before the issuance of the approval of final construction plans. If the easement is not formally described as part of a subdivision or land partition plat, the developer is to convey a sewer facility easement to the City of Madras that will be formally recorded in the Jefferson County Clerk’s office. No permanent structures can be constructed within the easement area, unless specific written permission, with conditions, is granted by the Public Works Director. Landscaping within sanitary sewer easements shall be approved by the City.
Design Life. Building Services design life will generally be in accordance with CIBSE Table B18 .2 The design life of the structure is 60 years. The design life of the envelope will generally be in accordance with BCO recommendations.
Design Life. The Design Report shall document the anticipated design life for the pumping facility and components. The facility shall be designed to meet the design life identified in the Infrastructure Design Criteria Manual and Draft Supplement Design Criteria. Deviations shall be documented in the report.
Design Life. The solution and all components used shall be supported by the OEM for a minimum of 10 years.
Design Life. The Permanent Works shall have a minimum design life of 25 years.
Design Life. The design life of the conveyor system is 45 years
Design Life. (a) Design Life is defined as the period over which an Asset must perform its intended function without replacement, refurbishment or significant maintenance. Assets include Asset Items and Asset Sub-Items which for the purpose of project Asset management are also identified by Asset Element and Asset Type. (b) Where Asset Items and Asset sub-items are defined in Appendix 24 as having a design life less than specified in Table 4.1 below or where they are determined as being accessible for the purposes of Table 4.1below, the design will detail the methodology of replacement including access provisions for both inspection and replacement. Asset items which can not be replaced without closure or severe disruption to traffic (ie large culvert wingwalls) are deemed to be inaccessible. (c) Except as specified in Appendix 24 the various Assets will have the following minimum Design Life: (i) Inaccessible drainage elements 100 years (ii) drainage elements that are accessible for refurbishment including sedimentation and detention ponds and basins 20 years
Design Life. 9.2.2.1. All structural elements of the pontoon, brow and pontoon restraints shall have a design life of 50 years 9.2.2.2. Corrosion protection systems shall be applied to ensure a dry docking maintenance interval for all structural elements of at least 15 years. 9.2.2.3. Steel plate on structures in contact with the river at any time shall have a minimum thickness of 8mm. 9.2.2.4. The pontoon extension is to be fitted anodes to match existing and bolted to the pontoon in marked locations in order to allow regular inspection and replacement by divers working in zero visibility conditions.