Electrical System Design and Equipment Requirements Sample Clauses

Electrical System Design and Equipment Requirements. In general, the electrical systems and equipment described in this section shall, as a minimum, comply with the applicable requirements of NFPA 70 (National Electric Code) in areas where applicable, such as office buildings, and ANSI C2 (NESC), as well as the applicable equipment standards published by ANSI, IEEE, NEMA, etc. Circuit breakers, switchgear, and MCCs shall be UL approved. All Facility electrical equipment, including bus, breakers, transformers, motor control centers, etc., shall be designed to withstand the maximum available fault current. The Seller shall perform an EasyPower study on the electrical system, and shall provide the study to the Purchaser. A preliminary study shall be done before any equipment purchase. A final shall be done when complete data on furnished equipment is available.
AutoNDA by SimpleDocs
Electrical System Design and Equipment Requirements. In general, the electrical systems and equipment described in this section shall, as a minimum, comply with the applicable requirements of NFPA 70 (National Electric Code) in areas where applicable, such as office buildings, and ANSI C2 (NESC), as well as the applicable equipment standards published by ANSI, IEEE, and NEMA. Circuit breakers, switchgear, and MCCs shall be UL approved. All Facility electrical equipment, including bus, breakers, transformers, motor control centers, etc., shall be designed to withstand the maximum available fault current. The Seller shall perform an EasyPower study on the electrical system and shall provide the study to the Purchaser. A preliminary study shall be done before any equipment purchase. A final shall be done when complete data on furnished equipment is available. During all operating conditions with all electrical power distribution equipment in service (e.g., no tie breakers closed) other than during the starting of large motors, the voltage at motor terminals shall be maintained between 90% and 110% of motor rated voltage. Temporary voltage drops during motor starting shall not extend below 80% of the motor rated voltage at the terminals of the largest motor on the buses being started, and non-starting motors on the same bus shall not have a bus voltage of less than 90% of rated voltage. All electrical ac auxiliary systems (medium & low voltage) must adequately mitigate arc-flash hazards as addressed in NFPA-70E and meet the following minimal requirements: All breakers, bus, starters, and cables in medium and low voltage switchgear, MCCs, switchboards, load centers, and panel boards must be able to have maintenance performed solely in a de-energized state, without unacceptable impacts to the rest of the plant (i.e. critical equipment must still be able to run) Systems shall be designed to limit max arc-flash hazard to 25 cals/cm2 @18inches from live part Breakers requiring racking, shall have remote racking devices Other devices/schemes such as maintenance switches and zone protection shall be explored in addressing these hazards Arc flash hazard calculations shall be made for all medium and low voltage ac electrical systems down to the 120v level per PG&E calculation guidelines and labeled per PG&E labeling standards.

Related to Electrical System Design and Equipment Requirements

  • Equipment and Software Requirements In order to view and retain electronic communications that we make available to you, you must have: • A PC or other device with an Internet browser that has “cookies” enabled and supports 128 bit encryption • An Internet connection • An email address • A PDF viewer (such as Adobe Reader) • A printer or computer with sufficient electronic storage space All communications shall be delivered to the last address we have on file for you. These notices will be sent through electronic delivery (email) and will be considered delivered the same day as sent. If you have opted out of electronic delivery, communications sent to you through the United States Postal Service are considered delivered 5 business days after the postmark date. It is your responsibility to notify the Custodian of any email address change or residential address change. We will not be held liable for any losses or damages if you have not provided Custodian with the most current address information. The electronically signed copy of this document should be considered equivalent to a printed hard copy form. It is considered a true and complete record of the document, admissible in arbitration and/or administrative hearings or proceedings. Your electronic signature on the Application and other electronic forms such as the Investment Direction are considered valid and the same as if the paper form or Application were signed.

  • Installation, Maintenance, Testing and Repair Unless otherwise agreed in writing by the Parties, to the extent required by Applicable Law, Interconnection provided by a Party shall be equal in quality to that provided by such Party to itself, any subsidiary, affiliates or third party. If either Party is unable to fulfill its obligations under this Section 14.2, it shall notify the other Party of its inability to do so and will negotiate alternative intervals in good faith. The Parties agree that to the extent required by Applicable Law, the standards to be used by a Party for isolating and clearing any disconnections and/or other outages or troubles shall be at parity with standards used by such Party with respect to itself, any subsidiary, affiliate or third party.

  • Equipment Requirements No Equipment is provided to Customer as part of this Service.

  • Contractor’s Equipment Payment for required equipment owned by the Construction Manager or an affiliate of the Construction Manager will be based solely on an hourly rate derived by dividing the current appropriate monthly rate by 176 hours. No payment will be made under any circumstances for repair costs, freight and transportation charges, fuel, lubricants, insurance, any other costs and expenses, or overhead and profit. Payment for such equipment made idle by delays attributable to the Government will be based on one-half the derived hourly rate under this subsection.

  • System Upgrade Facilities and System Deliverability Upgrades Connecting Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities and System Deliverability Upgrades shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.

  • Solicitations for Subcontractors, Including Procurements of Materials and Equipment In all solicitations either by competitive bidding or negotiation made by the contractor for work to be performed under a subcontract, including procurements of materials or leases of equipment, each potential subcontractor or supplier shall be notified by the contractor of the contractor's obligations under this contract and the Regulations relative to nondiscrimination on the grounds of race, color, or national origin, sex, age, and disability/handicap.

  • Equipment and Software To use the Mobile Remote Deposit Services, you must obtain and maintain at your expense, compatible equipment and software that we may specify from time to time.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • MAINTENANCE AND REPAIR; RULES Tenant will, at its sole expense, keep and maintain the Premises and appurtenances in good and sanitary condition and repair during the term of this Agreement and any renewal thereof. Without limiting the generality of the foregoing, Tenant shall:

  • Design Elements The School shall implement and maintain the following essential design elements of its educational program:

Time is Money Join Law Insider Premium to draft better contracts faster.