Instrumentation and Electrical Sample Clauses

Instrumentation and Electrical. 10.1. Gas-drive packages shall have Xxxxxx control panel for CAT 3500 series engines and changed to Xxxxx-Xxxxxxx Compact Logix PLC for CAT 3600 series engines as required by ACMP. 10.2. Pressure Transmitters shall be stainless steel, 4-20mA, 0.25% of full scale accuracy, rated for pressure and temperature of service with a 200% overpressure rating, greater than 2 kHz response time. 10.3. Gauges shall be industrial heavy duty, liquid filled with 2 1⁄2” faces. Wika, Xxxxxxxx or approved equivalent. Each pressure gauge shall include a pulsation dampener. 10.4. All instrumentation, controls, and valves shall be provided with stainless steel unique name tags and attached to devices by stainless steel cable. 10.5. Thermocouples shall be J or K Type with 18 gauge wire. EXECUTION VERSION 10.6. Scrubber level switches shall be Xxxxxx LS200, 2000 PSI, 2” NPT. 10.7. Scrubber level controllers shall be Norriseal Model EVS or Xxxxxx Equivalent. 10.8. Liquid level gauges installed on vessels such as the suction scrubber shall be Penbethy reflex type and properly braced to prevent vibration. 10.9. Tubing shall be 316 Stainless Steel. 10.10. All pneumatic controls shall have a manifold to a common instrument air line. Instrument air filters and regulators shall be provided as required for control operation. EXECUTION VERSION 10.11. Control panel shall have the following: NEMA 4 carbon steel weatherproof enclosure, CSA certified Class 1 Division 2 Groups C&D, 24 VDC powered, Ethernet communications with gauges, transmitters and snubbers, window kit for HMI, and gauges where applicable to include suction and discharge pressure for each stage, and engine vacuum/boost pressure. 10.12. Control panel enunciator to include local start, stop and reset push buttons, local ESD pushbutton, power, unit running, unit alarm, and unit shutdown indication, and a power on/off switch. 10.13. Customer connection terminal block shall include a normally open contact for run status, and a 24VDC remote shutdown relay. 10.14. Control panel analog outputs shall include, where applicable, main driver speed control, suction valve control, recycle valve control, and cooler fan(s) speed control. 10.15. Control panel analog inputs to include at where applicable compressor oil pressure, suction and discharge pressure for each stage, compressor vibration (2), driver vibration (2), and catalyst differential pressure. Also include engine RPM high speed counter where applicable. 10.16. Control panel therm...
AutoNDA by SimpleDocs
Instrumentation and Electrical. Any interface with Bayer to share information needs to be defined. Bayer needs to know the waste water flow, pH, environmental flows, utilities flows and product flows. EDNC shall install emergency communications systems in accordance with Bayer specifications.

Related to Instrumentation and Electrical

  • Documentation and Record Keeping 1. Records to be Maintained Subrecipient shall maintain all records required by the Federal regulations specified in 24 CFR 570.506 that are pertinent to the activities to be funded under this Contract. Such records shall include, but not be limited to: a. Records providing a full description of each activity undertaken; b. Records demonstrating that each activity undertaken meets the one of the National Objectives of the CDBG program; c. Records required to determine the eligibility of activities; d. Records required to document the acquisition, improvement, use, or disposition of real property acquired or improved with CDBG assistance; e. Records documenting compliance with the fair housing and equal opportunity components of the CDBG program; f. Financial records as required by federal regulations 24 CFR 570.502, and 24 CFR 84.21-28; and g. Other records necessary to document compliance with Subpart K of 23 CFR.

  • Documentation and compliance (a) The data importer shall promptly and adequately deal with enquiries from the data exporter that relate to the processing under these Clauses. (b) The Parties shall be able to demonstrate compliance with these Clauses. In particular, the data importer shall keep appropriate documentation on the processing activities carried out on behalf of the data exporter. (c) The data importer shall make available to the data exporter all information necessary to demonstrate compliance with the obligations set out in these Clauses and at the data exporter’s request, allow for and contribute to audits of the processing activities covered by these Clauses, at reasonable intervals or if there are indications of non-compliance. In deciding on a review or audit, the data exporter may take into account relevant certifications held by the data importer.

  • Implementation and Review The Parties shall consult annually, or as otherwise agreed, to review the implementation of this Chapter and consider other matters of mutual interest affecting trade in services. (10) 10 Such consultations will be addressed under Article 170 (Free Trade Commission) of Chapter 14 (Administration of the Agreement).

  • Installation and Use You may install and use the Software only for the number of licenses acquired by you. In order to exercise your rights to the Software under this Agreement, you must activate your copy of the Software in the manner described during the launch sequence.

  • Heating, Ventilation and Air Conditioning Landlord shall furnish to the Premises heating, ventilation and air-conditioning (“HVAC”) in accordance with the Design Standards set forth in Exhibit D during Ordinary Business Hours. Landlord shall have access to all air-cooling, fan, ventilating and machine rooms and electrical closets and all other mechanical installations of Landlord (collectively, “Mechanical Installations”), and Tenant shall not construct partitions or other obstructions which may interfere with Landlord’s access thereto or the moving of Landlord’s equipment to and from the Mechanical Installations. No Tenant Party shall at any time enter the Mechanical Installations or tamper with, adjust, or otherwise affect such Mechanical Installations. Landlord shall not be responsible if the HVAC System fails to provide cooled or heated air, as the case may be, to the Premises in accordance with the Design Standards by reason of (i) any equipment installed by, for or on behalf of Tenant, which has an electrical load in excess of the average electrical load and human occupancy factors for the HVAC System as designed, or (ii) any rearrangement of partitioning or other Alterations made or performed by, for or on behalf of Tenant. Tenant shall install, if missing, blinds or shades on all windows, which blinds and shades shall be subject to Landlord’s approval, and shall keep operable windows in the Premises closed, and lower the blinds when necessary because of the sun’s position, whenever the HVAC System is in operation or as and when required by any Requirement. Tenant shall cooperate with Landlord and shall abide by the rules and regulations which Landlord may reasonably prescribe for the proper functioning and protection of the HVAC System. Tenant acknowledges that the server room in the Premises currently has three heat pumps installed, being two 4-ton units, and one 2.5-ton unit (the “Existing Heat Pumps”). The 2.5-ton unit is currently connected and operational. Tenant shall determine whether it is satisfied with the condition of the Existing Heat Pumps and Landlord shall not have any responsibility or liability for the condition, operation, maintenance, repair or replacement of the Existing Heat Pumps. Tenant may operate the Existing Heat Pumps. Tenant shall be responsible for, and pay directly for, all necessary maintenance and repairs to the Existing Heat Pumps. Tenant shall reimburse Landlord monthly for the cost of all utility services used to operate the Existing Heat Pumps within 10 Business Days after receipt of Landlord’s invoice for such amount. Landlord may measure Tenant’s usage of such utility services by either a sub-meter or by other reasonable methods such as by temporary check meters or by survey. Tenant, at its cost, may replace the Existing Heat Pumps with one or more new heat pumps, provided, however, that the capacity of such replacement heat pump(s) shall not exceed the 10.5-ton capacity cooling capacity of the Existing Heat Pumps.

  • EVALUATION AND MONITORING The ORGANIZATION agrees to maintain books, records and other documents and evidence, and to use accounting procedures and practices that sufficiently and properly support the complete performance of and the full compliance with this Agreement. The ORGANIZATION will retain these supporting books, records, documents and other materials for at least three (3) calendar years following the year in which the Agreement expires. The COUNTY and/or the State Auditor and any of their representatives shall have full and complete access to these books, records and other documents and evidence retained by the ORGANIZATION respecting all matters covered in and under this Agreement, and shall have the right to examine such during normal business hours as often as the COUNTY and/or the State Auditor may deem necessary. Such representatives shall be permitted to audit, examine and make excerpts or transcripts from such records, and to make audits of all contracts, invoices, materials, and records of matters covered by this Agreement. These access and examination rights shall last for three calendar years following the year in which the Agreement expires. The COUNTY intends without guarantee for its agents to use reasonable security procedures and protections to assure that related records and documents provided by the ORGANIZATION are not erroneously disclosed to third parties. The COUNTY will, however, disclose or make this material available to those authorized by/in the above paragraph or permitted under the provisions of Chapter 42.56 RCW without notice to the ORGANIZATION. The ORGANIZATION shall cooperate with and freely participate in any other monitoring or evaluation activities pertinent to this Agreement that the COUNTY finds needing to be conducted.

  • Systems The details of any systems work will be determined after a thorough business analysis. System's work will be billed on a time and material basis. Investors Bank provides an allowance of 10 systems hours for data extract set up and reporting extract set up. Additional hours will be billed on a time and material basis.

  • Agreement Administration and Communications A. Under this Agreement, either of the representatives of the Judicial Council identified below will monitor the Work and act as the Judicial Council’s liaisons with the Contractor: i. The Meeting Planner will be MPname. B. The Judicial Council may reallocate funds between the estimated amounts set forth in Exhibit G, without an Amendment to this Agreement, as long as the total amount to be paid under this Agreement does not exceed the Contract Amount. C. All requests and communications about the Work to be performed under this Agreement, including signing of any BEO’s, shall be made through the Meeting Planner or his or her designee or successor. D. Any Notice from the Contractor to the Judicial Council shall be delivered to the following address: MP name, Meeting Planner Judicial Council of California 000 Xxxxxx Xxxx Xxxxxx Xxx Xxxxxxxxx, XX 00000-0000 E. Notice to the Contractor shall be directed to the Contractor’s liaison, Attn, or his or her designee or successor, at the following address: Attn: Ktr DifferentAddress1 DifferentAddress2

  • Program Monitoring and Evaluation The Recipient shall prepare, or cause to be prepared, and furnish to the Association not later than six months after the Closing Date, a report of such scope and in such detail as the Association shall reasonably request, on the execution of the Program, the performance by the Recipient and the Association of their respective obligations under the Legal Agreements and the accomplishment of the purposes of the Financing.”

  • Integration and Amendment This Agreement represents the entire and integrated agreement between the Town and the Contractor and supersedes all prior negotiations, representations, or agreements, either written or oral. Any amendments to this Agreement must be in writing and be signed by both the Town and the Contractor.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!