Receptacles. 2.1.1 Wiring devices shall be UL listed and suitable for the application.
Receptacles. Convenience receptacles shall be limited to eight per circuit, with a circuit loading of 180 xxxxx for each receptacle, unless specific conditions necessitate other requirements. Maximum spacing of receptacles along walls in office areas and maintenance shop shall not exceed 12 feet. Each office shall have a minimum of two receptacles. 120 V convenience receptacles shall be installed in operating areas at 70 foot intervals, on the basis of 00-xxxx xxxxxxxxx xxxxx. Convenience receptacles shall be provided at each manway platform. Office and administration areas shall have a duplex receptacle, two wire, three pole, grounded type, rated 15 amperes, 125 volts ac. Welding outlet circuits shall consist of No. 4 AWG or larger conductors with circuit protective devices located in the low voltage motor control centers. Each circuit shall supply a maximum of three welding receptacles. Outlets shall be provided in the operating areas and shall be located at points that may require the greatest service. Outlets shall be located so that no point in that area requires a welding cable in excess of 125 feet. Welding receptacles shall be three wire, four pole, rated 60 amperes, 600 volts ac, three phase.
Receptacles. Lessee shall provide and use suitable covered metal receptacles for all such garbage, trash and other refuse throughout the Premises. Piling of boxes, cartons, trash or similar items on the Premises, including the building, facilities, improvements and parking lot 00-0000-0000 /839870| Lease - 000 X. Xxx Xxxxxxx Xxxxxx, Xxxxx X, Xx Xxxx, Xxxxx | xxx adjacent to the building, shall not be permitted at any time. Additionally, the placement of trash receptacles shall be at locations approved by the City’s Real Estate Manager.
Receptacles. (a) This specification applies to single and duplex receptacles and receptacles of other voltage and ampacity as indicated on the drawings.
Receptacles. Receptacles may be made of wood or metal (not pre-cast concrete) and should be sturdy and durable. They should be complimentary to all other furnishings and materials. • Receptacles should be complementary in scale, colour and materials to building and design. • Receptacles should be located conveniently for patrons use without creating visual clutter. • Receptacles must have a top enclosure with an opening in the side, just under the top for disposal of trash. • All trash receptacles must be bear proof, if they are located outside.
Receptacles. The Franchisee shall provide 96-gallon Mobile Carts to each curbside residential dwelling unit located within the City. The Franchisee shall be required to pick up all garbage and rubbish generated from residential dwellings that has been placed in a Mobile Cart and placed at Curbside (or such other single collection point as may be agreed upon by the Franchisee and the customer). Franchisee shall not be required to collect residential waste not generated in the residence served. Non-containerized rubbish, trash or yard waste shall not be collected by the Franchisee. However, during high volume periods such as Christmas, arrangement to collect non-containerized materials will be made as agreed upon by the Franchisee and the City Manager.
Receptacles. The Franchisee shall provide Dumpsters or Mobile Carts to each commercial business establishment. The quantity and/or size of the receptacles shall be mutually agreed upon by the Franchisee and each commercial business establishment.
Receptacles. A. Product Description: NEMA WD 1, Heavy-duty general use receptacle.
Receptacles. Every habitable space in a dwelling or dwelling unit, except lodging rooms that do not allow cooking, microwaves, space heaters or extension cords, shall contain at least two (2) separate and remote receptacle outlets and one (1) wall or ceiling-type electric light fixture controlled by a remote switch. If a ceiling or wall-type light fixture is not installed, one of the two (2) required floor or wall-type convenience outlets shall be controlled by a remote switch. Every laundry area shall contain at least one (1) grounded-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one (1) receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. Convenience outlets are to be located to prevent use of extension cords in accordance with National Electrical Code (NEC) 400-8/Chapter Comm. 16 of the Wisconsin Administrative Code. All extension cords, temporary wiring and exposed or abandoned wiring shall be removed.
Receptacles. Licensor shall, at its sole cost, provide sufficient waste receptacles at each location.