Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.
Training Committee The parties to this Agreement may form a Training Committee. The Training Committee will be constituted by equal numbers of Employer nominees and ETU employee representatives and have a charter which clearly states its role and responsibilities. It shall monitor the clauses of this Agreement which relate to training and ensure all employees have equal access to training.
Operating Committee the Consortium’s managing body, composed of representatives of the Manager and the Contractors, pursuant to Annex XI.
MINISTRY/SCHOOL BOARD INITIATIVES ETFO will be an active participant in the consultation process to develop a Ministry of Education PPM regarding Ministry/School Board Initiatives.
Hospital-Association Committee (a) There shall be a Hospital-Union Committee comprised of representatives of the Hospital, one of whom shall be the Chief Nursing Officer or designate and of the Union, one of whom shall be the Bargaining Unit President or designate. The number of representatives is set out in the Appendix of Local Provisions and the membership of the Committee may be expanded by mutual agreement. (b) The Committee shall meet every two (2) months unless otherwise agreed and as required under Article 8.01 (a) (iv). The duties of chair and secretary shall alternate between the parties. Where possible, agenda items will be exchanged in writing at least five (5) calendar days prior to the meeting. A record shall be maintained of matters referred to the Committee and the recommended disposition, if any, unless agreed to the contrary. Copies of the record shall be provided to Committee members. (c) The purpose of the Committee includes: i) promoting and providing effective and meaningful communication of information and ideas, including but not limited to workload measurement tools and the promotion of best practices. Such communication may include discussion of nursing workload measurement and patient acuity systems. The Hospital will provide, upon request, information on workload measurement systems applicable to nursing currently used by the Hospital, and evaluations completed by the Hospital of such systems. ii) reviewing professional responsibility complaints with a view to identifying trends and sharing organizational successes and solutions, making joint recommendations on matters of concern including the quality and quantity of nursing care and discussing the development and implementation of quality initiatives; iii) making joint recommendations to the Chief Nursing Officer on matters of concern regarding recurring workload issues including the development of staffing guidelines, the use of agency nurses and use of overtime; iv) dealing with complaints referred to it in accordance with the provisions of Article 8, Professional Responsibility; v) discussing and reviewing matters relating to orientation and in- service programs; vi) promote the creation of full-time positions for nurses, and discuss the effect of such changes on the employment status of the nurses. This may include the impact, if any, on part-time and full-time, job sharing and retention and recruitment. (d) The Hospital agrees to pay for time spent during regular working hours for representatives of the Union attending at such meetings. (e) Where a Committee representative designated by the Union attends Committee meetings outside of her or his regularly scheduled hours, she or he will be paid for all time spent in attendance at such meetings at her or his regular straight time hourly rate of pay. Such payment shall be limited to two (2) Committee representatives per meeting.
Teams One team for the purposes of the Event shall consist of one Vehicle. Each Vehicle can contain a maximum of three Team Members, provided such Team Members have entered into a Team Entry Agreement with the Company or have otherwise agreed in writing to participate in the Event upon and subject to the Terms of Entry and the Event Rules. For the avoidance of doubt, it is the sole responsibility of each Team to inform themselves of the maximum numbers of persons legally permitted to travel in the Vehicle under Relevant Law. The Company shall provide each Team with the contact details of the Approved Hirer who will be able to provide each Team with a Vehicle for use in the Event, subject to the Team entering into an agreement (the "Borrowing Agreement") with the Hirer outlining the terms of use of the Vehicle. Should the Vehicle not be delivered to the Designated Finish Point by 14:00 local time on 19th September 2021, then the team will be liable for the "Hire Costs" outlined below. Each Vehicle will be of a similar specification to that outlined in Schedule 4 to the Team Entry Agreement. For the avoidance of doubt, the Company shall make no representations or warranties as to the suitability of the Approved Hirer or of the Vehicle for participation in the Event and any rights or warranties which a Team may have or be granted in relation to the Vehicle shall be limited to those contained in the Rental Agreement or implied by any Relevant Law.
Power System Stabilizers The Developer shall procure, install, maintain and operate Power System Stabilizers in accordance with the requirements identified in the Interconnection Studies conducted for Developer’s Large Generating Facility. NYISO and Connecting Transmission Owner reserve the right to reasonably establish minimum acceptable settings for any installed Power System Stabilizers, subject to the design and operating limitations of the Large Generating Facility. If the Large Generating Facility’s Power System Stabilizers are removed from service or not capable of automatic operation, the Developer shall immediately notify the Connecting Transmission Owner and NYISO. The requirements of this paragraph shall not apply to wind generators.
System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.
School Board Any reference to School Board or District in this Agreement shall mean the District and/or its designated officials.
System Operations Each party, at its own expense, shall provide and maintain the equipment, software, services and testing necessary to transmit Data Communications to, and receive Data Communications from the parties’ respective Receipt Computers.