Real-Time Data. (a) No later than sixty (60) Days prior to the Commercial Operation Date, Seller shall install one or more stand-alone meteorological towers at the Facility Site and the measurement, telemetry and communications equipment necessary or advisable (according to Accepted Industry Practices) to measure, record, store and provide to Buyer the data required by this Section 8.4 on the basis required by this Section 8.4. Seller shall maintain the same (according to the standards set forth in Section 9.1(b)) until the end of the Delivery Term.
Real-Time Data. (a) No later than sixty (60) Days prior to the Commercial Operation Date, Seller shall install one or more stand-alone meteorological stations at the Facility Site and the measurement, telemetry and communications equipment necessary or advisable (according to Accepted Industry Practices) to measure, record, store and provide to Buyer the data required by this Section 8.4 on the basis required by this Section 8.4. Seller shall maintain the same (according to the standards set forth in Section 9.1(b)) until the end of the Delivery Term.
Real-Time Data. 15.1.1 During the Operation Period, the Authority shall give the Operator the access to the raw feed of the monitoring system pertaining to the performance of the Operator under this Contract and as generated by ITS. If the Authority fails to provide the daily raw feed then it shall be deemed to be an Authority Event of Default.
Real-Time Data. Commencing on the first date on which Facility Energy is generated, and continuing throughout the Delivery Term, Seller shall provide to Buyer the following data on a real-time basis:
Real-Time Data. The Municipality agrees to provide to the County the real time On-demand service route information in a format approved by DTPW, or its successor department, such as provided by a Global Positioning System (GPS), and which is compatible with, and may be integrated into, the County’s smartphone transit tracker application and common third-party applications.
Real-Time Data. (a) No later than sixty (60) Days prior to the [Commercial Operation Date]169 [Delivery Term Commencement Date (to the extent not already installed)]170, Seller shall install one or more stand-alone meteorological towers at the Facility Site and the measurement, telemetry and communications equipment necessary or advisable (according to Accepted Industry Practices) to measure, record, store and provide to Buyer the data required by this Section 8.4 on the basis required by this Section 8.4. Seller shall maintain the same (according to the standards set forth in Section 9.1(b)) until the end of the Delivery Term.
Real-Time Data. Seller shall communicate all data necessary for Company to integrate the Facility into Company’s EMCC in real time through the Facility’s SCADA System in accordance with Exhibit I - AGC Protocols; Data Collection; Technical Specifications. Seller shall maintain the Facility’s SCADA System so that it is capable of interfacing with and reacting to Company’s AGC Set-Point and responding to signals from the Company’s EMCC in accordance with the AGC Protocols. Seller shall use Commercially Reasonable Efforts to adjust the real time Park Potential of the Facility when Company communicates to Seller a measured difference of plus or minus two percent between the metered Renewable Energy and Park Potential, during periods when generation is not curtailed. From and after the Commercial Operation Date, Seller shall provide Company, at Seller’s expense, real time performance and meteorological data for all Solar Units and meteorological towers at the Facility in accordance with Exhibit I - AGC Protocols; Data Collection; Technical Specifications for the Term of this PPA. Seller shall maintain Seller-owned data collection systems that are compatible with Company’s PI System. Seller shall ensure that real time communications capabilities are available and maintained for transmission to Company’s PI System. Seller shall ensure that all meteorological equipment at a minimum meets the specifications set forth in Exhibit I - AGC Protocols; Data Collection; Technical Specifications. Company shall have the right to disclose data gathered through the Company’s PI System publicly; provided, however, that such data is (i) masked to obscure the origin of the data and (ii) aggregated so that the data cannot be correlated and used by competitors of Seller and/or the supplier of the Solar Units.
Real-Time Data. (A) Seller shall communicate all data necessary for Company to integrate the Facility into Company’s EMCC in real time through the Facility’s SCADA System in accordance with Exhibit I - AGC Protocols; Dispatch and Availability Notices; Data Collection; Technical Specifications, and subject to Exhibit O – Battery Storage System Operating Procedures. Seller shall maintain the Facility’s SCADA System so that it is capable of interfacing with and reacting to Company’s AGC Set-Point and responding to signals from Company’s EMCC in accordance with the AGC Protocols, subject to Exhibit O – Battery Storage System Operating Procedures.
Real-Time Data. (A) Seller shall communicate all data necessary for Company to integrate the Facility into Company’s EMCC in real time through the Facility’s SCADA System in accordance with the AGC Protocols. Seller shall maintain the Facility’s SCADA System so that it is capable of interfacing with and reacting to Company’s AGC Set-Point and responding to signals from the Company’s EMCC in accordance with the AGC Protocols.
Real-Time Data. Reserve Holder shall deliver, at its own expense, the following unit-specific data to a point of delivery indicated by Fingrid: · volume of the frequency controlled normal operation reserve (MW) to be maintained