TENANT IMPROVEMENT INFORMATION Sample Clauses

TENANT IMPROVEMENT INFORMATION. 1. Office subdividing partitions shall comply with applicable building codes and local requirements and ordinances shall be provided as part of the Tenant Improvement Allowance. Partitioning shall extend from the finished floor to the finished ceiling and shall be designed to provide a minimum sound transmission class (STC) of 37. Partitioning shall be installed by the Lessor at locations to be determined by the Government as identified in the design intent drawings. They shall have a flame spread rating of 25 or less and a smoke development rating of 50 or less (ASTM E-84).
AutoNDA by SimpleDocs
TENANT IMPROVEMENT INFORMATION. Door identification shall be installed in approved locations adjacent to office entrances as part of the Tenant Improvement Allowance. The form of door identification shall be approved by the Contracting Officer.
TENANT IMPROVEMENT INFORMATION. 1. In the event the Government chooses to install wall covering as part of the Tenant Improvement Allowance, the minimum standard is established as vinyl or polyolefin commercial wall covering weighing not less that 13 ounces per square yard as specified in FS CCC-W-408C or equivalent. The finish shall be pre-approved by the Contracting Officer.
TENANT IMPROVEMENT INFORMATION. Doors shall have door handles or door pulls with heavy-weight hinges. All doors shall have corresponding door stops (wall- or floor-mounted) and silencers. All door entrances leading into the Government-demised area from public corridors and exterior doors shall have automatic door closers. Doors designated by the Government shall be equipped with 6pin tumbler cylinder locks, and strike plates. All locks shall be master keyed. The Government shall be furnished with at least two master keys for each lock.
TENANT IMPROVEMENT INFORMATION. 1. Floor covering shall be either carpet or resilient flooring, as specified in the Government's drawings. Floor perimeters at partitions shall have wood, rubber, vinyl, carpet base, or an equivalent pre-approved by the Contracting Officer.
TENANT IMPROVEMENT INFORMATION. 1. Should the Government’s security requirements require sealed conduit to house the telecommunications transmission medium, the Lessor shall provide such conduit at the expense of the Government
TENANT IMPROVEMENT INFORMATION. 1. The Lessor shall provide as part of the Tenant Improvement Allowance separate data, telephone, and electric junction boxes for the base feed connections to Government-provided modular or systems furniture, when such feeds are supplied via wall outlets or floor penetrations. When overhead feeds are used, junction boxes shall be Installed for electrical connections. Raceways shall be provided throughout the furniture panels to distribute the electrical, telephone, and data cable. The Lessor shall provide all electrical service wiring and connections to the furniture at designated junction points. Each electrical junction shall contain an 8-wire feed consisting of 3 general-purpose 120-V circuits with 1 neutral and 1 ground wire, and a 120-V isolated-ground circuit with 1 neutral and 1 Isolated-ground wire. A 20-ampere circuit shall have no more than 8 general-purpose receptacles or 4 isolated-ground “computer” receptacles. SFO NO. 4TX0510 62 INITIALS: /S/ & /S/ 7/26/2005 LESSOR GOV'T
AutoNDA by SimpleDocs
TENANT IMPROVEMENT INFORMATION. 1. Prior to occupancy, all surfaces within the Government-demised area which are designated by GSA for painting shall be newly finished in colors acceptable to GSA.
TENANT IMPROVEMENT INFORMATION. Suite entry doors shall be provided as part of the Tenant Improvements at the Government’s expense and shall have a minimum clear opening of 32” wide x 84” high (per leaf). Doors shall meet the requirements of being a flush, solid-core, 1-3/4-inch thick, wood door with a natural wood veneer face or an equivalent pre-approved by the Contracting Officer. Hollow core wood doors are not acceptable. They shall be operable by a single effort and shall be in accordance with National Building Code requirements. Doors shall be installed in a metal frame assembly, finished with a semi-gloss oil based paint finish. SFO NO. 4TX0510 48 INITIALS: /S/ & /S/ 7/26/2005 LESSOR GOV'T
TENANT IMPROVEMENT INFORMATION. Doors within the Government-demised area shall be provided as part of the Tenant Improvements at the Governments expense and shall have a minimum clear opening of 36” wide x 80” high. Doors shall meet the requirements of being a flush, solid-core, wood door with a natural wood veneer face or an equivalent pre-approved by the Contracting Officer. Hollow core wood doors are not acceptable. They shall be operable with a single effort and shall be in accordance with National Building Code requirements. Doors shall be installed in a metal frame assembly, primed and finished with a low VOC semi-gloss oil based paint with no formaldehyde.